Aortic arch branching variations and risk of cerebrovascular accidents in patients with a left ventricular assist device

被引:0
|
作者
Zijderhand, Casper F. [1 ,3 ]
Sjatskig, Jelena [1 ]
Scharink, Denne A. [1 ]
Peek, Jette J. [1 ]
Birim, Ozcan [1 ]
Bekkers, Jos A. [1 ]
Bogers, Ad J. J. C. [1 ]
Caliskan, Kadir [2 ]
机构
[1] Erasmus MC Univ Med Ctr, Dept Cardiothorac Surg, Thoraxcenter, Rotterdam, Netherlands
[2] Erasmus MC Univ Med Ctr, Dept Cardiol, Rotterdam, Netherlands
[3] Erasmus MC, Thoraxcenter, Univ Med Ctr Rotterdam, Room RG-620,Dr Molewaterplein 40, NL-3015 GD Rotterdam, Netherlands
关键词
adverse events; anatomic variations; aortic arch branching; left ventricular assist device; STROKE; COMPLICATIONS; MORTALITY; SUPPORT; EVENTS; IMPACT;
D O I
10.2459/JCM.0000000000001570
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims This retrospective study investigated the association between anatomical variations in the aortic arch branching and adverse events, including the risk of cerebrovascular accidents (CVAs), in patients with a left ventricular assist device (LVAD).Methods Medical charts were reviewed for all patients with HeartMate 3 LVAD support at our center from 2016 to 2021. Computed tomography scans were evaluated to categorize the variations in the aortic arch branching based on seven different types, as described in the literature.Results In total, 101 patients were included: 86 (85.1%) with a normal branching pattern and 15 (14.9%) with an anatomical variation. The following variations were observed: eight (7.9%) with a bovine arch and seven (6.9%) with a left vertebral arch. The median age was 57 years, 77.2% were men, and the median follow-up was 25 months. No difference was found in the rate of early (< 30 days) re-exploration due to bleeding after LVAD implantation. The rate of CVA and mortality did not differ significantly between patients with a normal arch or an anatomical variation during follow-up, with hazard ratios of 1.47 [95% confidence interval (CI): 0.48-4.48; P = 0.495] and 0.69 (95% CI: 0.24-1.98; P = 0.489), respectively.Conclusion This preliminary study showed no differences in early and long-term adverse events, including CVA, when comparing patients with a variation in the aortic arch branching to patients with a normal aortic arch. However, knowledge of the variations in aortic arch branching could be meaningful during cardiac surgery for potential differences in surgical events in the perioperative period.
引用
收藏
页码:44 / 50
页数:7
相关论文
共 50 条
  • [31] Aortic regurgitation after left ventricular assist device placement
    Momeni, M
    Van Caenegem, O
    Van Dyck, MJ
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (03) : 409 - 410
  • [32] Aortic Root Thrombosis in patients with HeartMate 3 left ventricular assist device support
    Carey, Matthew R.
    Marshall, Dylan
    Clerkin, Kevin
    Laracuente, Ronald
    Sanchez, Joseph
    Jain, Sneha S.
    Raikhelkar, Jayant K.
    Leb, Jay S.
    Kaku, Yuji
    Yuzefpolskaya, Melana
    Naka, Yoshifumi
    Colombo, Paolo C.
    Sayer, Gabriel T.
    Takeda, Koji
    Uriel, Nir
    Topkara, Veli K.
    Fried, Justin A.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (06): : 866 - 875
  • [33] Periprocedural Dynamics of Aortic Regurgitation in Patients Supported With an Impella Left Ventricular Assist Device
    Butala, Brian
    Yu, Raymond
    Schorr, Rebecca
    Gologorsky, Edward
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (03) : 659 - 662
  • [34] Transcatheter aortic valve implantation in patients with a left ventricular assist device: a word of caution
    Ali, Jason
    Catarino, Pedro
    Abu-Omar, Yasir
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1309 - 1310
  • [35] AORTIC CALCIFICATION BURDEN AND MORTALITY IN PATIENTS TREATED WITH A DURABLE LEFT VENTRICULAR ASSIST DEVICE
    Alvarez, Paulino
    Fava, Agostina M.
    Alkhalfan, Fahad
    Tong, Michael
    Chaudhury, Pulkit
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 579 - 579
  • [36] Intermittent Aortic Valve Opening and Risk of Thrombosis in Ventricular Assist Device Patients
    Mahr, Claudius
    Chivukula, Venkat Keshav
    McGah, Patrick
    Prisco, Anthony R.
    Beckman, Jennifer A.
    Mokadam, Nahush A.
    Aliseda, Alberto
    ASAIO JOURNAL, 2017, 63 (04) : 425 - 432
  • [37] Percutaneous aortic valve closure for patients with left ventricular assist device-associated aortic insufficiency
    Alkhouli, Mohamad
    Melito, Betsy
    Ling, Frederick S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (07) : 1170 - 1173
  • [38] Transcatheter Aortic Valve Replacement Management of Aortic Insufficiency in Patients with Left Ventricular Assist Device Support
    Kar, B.
    Prathipati, P.
    Macedo, F. Y.
    Nathan, S.
    Radovancevic, R.
    Loyalka, P.
    Gregoric, I. D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S438 - S438
  • [39] Influence of aortic valve opening in patients with aortic insufficiency after left ventricular assist device implantation
    da Rocha e Silva, Jaqueline G.
    Meyer, Anna L.
    Eifert, Sandra
    Garbade, Jens
    Mohr, Friedrich W.
    Strueber, Martin
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (03) : 784 - 787
  • [40] Less Frequency of Aortic Valve Opening and Continuous Flow Device Are Risk Factors for Late Onset of Aortic Regurgitation in Patients with Left Ventricular Assist Device
    Hatano, M.
    Kinugawa, K.
    Shiga, T.
    Yao, A.
    Hirata, Y.
    Nishimura, T.
    Kyo, S.
    Ono, M.
    Nagai, R.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S8 - S8