Leakage in air handling units, the effects on the transmission of airborne infections

被引:4
|
作者
Szalanski, Pawel [1 ]
Cepinski, Wojciech [1 ]
Sayegh, Marderos Ara [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Environm Engn, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
Ventilation; Air leaks; Pressure distribution; Infection probability; SARS-CoV-2; COVID-19; Air handling units; Heat recovery systems; CONDITIONING SYSTEMS;
D O I
10.1016/j.buildenv.2023.110074
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The possibility of unfavorable leakages, especially with infectious diseases, in heat recovery systems in air handling units (AHU) is an essential issue. Typical configurations of AHU are analyzed in this aspect, based on their pressure distribution. It is shown that analyzing only for the design conditions is insufficient and that the changing pressure drops of the air filters due to their nonuniform soiling should be taken into account. The novelty of this paper is in proposed method of considering these leaks in the Wells-Riley model, widely used in the literature for airborne transmission of infectious diseases, including the leakage correction factor fhrleak (outdoor fresh air correction factor) based on EATR (exhaust air transfer ratio). Using the proposed method, for typical rooms, on the example of the SARS-CoV-2 virus and its Delta and Omicron variants, it is shown that considering leaks in heat recovery systems in AHU increases the probability of pathogen transmission. The highest increase in the absolute value of the probability of infection is observed in the single office scenario (4.1%) and in the auditorium with a sick speaker scenario (2.7%). The highest increase in reproduction number is observed in the auditorium with a sick speaker scenario (2.69). Such significant changes in reproduction number, including its change from R < 1.0 to R > 1.0 (auditorium with sick speaker for Delta variant of the virus), are crucial from the point of view of considering event scenarios; they slow down or accelerate the pandemic.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Research on Fault Detection Method for Air Handling Units System
    Sun, Liangliang
    Li, Yupeng
    Jia, Haiqi
    Ying, Yu
    IFAC PAPERSONLINE, 2019, 52 (03): : 79 - 84
  • [42] Application of machine learning in the fault diagnostics of air handling units
    Najafi, Massieh
    Auslander, David M.
    Bartlett, Peter L.
    Haves, Philip
    Sohn, Michael D.
    APPLIED ENERGY, 2012, 96 : 347 - 358
  • [43] Provision of frequency containment reserve with an aggregate of air handling units
    Rominger, Julian
    Kern, Fabian
    Schmeck, Hartmut
    COMPUTER SCIENCE-RESEARCH AND DEVELOPMENT, 2018, 33 (1-2): : 215 - 221
  • [44] Integrated Control and Fault Detection of Air-Handling Units
    Seem, John E.
    House, John M.
    HVAC&R RESEARCH, 2009, 15 (01): : 25 - 55
  • [45] VFD Application for Constant Volume Air-Handling Units
    Cho, Young-Hum
    Liu, Mingsheng
    Wang, Gang
    Wang, Jinrong
    Rauscher, Timothy
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 824 - +
  • [46] New sequencing control strategy for air-handling units
    Seem, John E.
    Park, Cheol
    House, John M.
    HVAC and R Research, 1999, 5 (01): : 35 - 58
  • [47] Solutions for enhancement of energy and exergy efficiencies in air handling units
    Liu, Wanli
    Kalbasi, Rasool
    Afrand, Masoud
    JOURNAL OF CLEANER PRODUCTION, 2020, 257
  • [48] The Noise Produced by the Air Handling Units Depending on the Type of Engine
    Jachimowicz, Sebastian
    Gladyszewska-Fiedoruk, Katarzyna
    10TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (10TH ICEE), 2017,
  • [49] LoLiMoT based MPC for air handling units in HVAC systems
    Schwingshackl, Daniel
    Rehrl, Jakob
    Horn, Martin
    BUILDING AND ENVIRONMENT, 2016, 96 : 250 - 259
  • [50] A probabilistic approach to diagnose faults of air handling units in buildings
    Dey, Debashis
    Dong, Bing
    ENERGY AND BUILDINGS, 2016, 130 : 177 - 187