Leakage in air handling units, the effects on the transmission of airborne infections

被引:4
|
作者
Szalanski, Pawel [1 ]
Cepinski, Wojciech [1 ]
Sayegh, Marderos Ara [1 ]
机构
[1] Wroclaw Univ Sci & Technol, Fac Environm Engn, Wybrzeze Wyspianskiego 27, PL-50370 Wroclaw, Poland
关键词
Ventilation; Air leaks; Pressure distribution; Infection probability; SARS-CoV-2; COVID-19; Air handling units; Heat recovery systems; CONDITIONING SYSTEMS;
D O I
10.1016/j.buildenv.2023.110074
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The possibility of unfavorable leakages, especially with infectious diseases, in heat recovery systems in air handling units (AHU) is an essential issue. Typical configurations of AHU are analyzed in this aspect, based on their pressure distribution. It is shown that analyzing only for the design conditions is insufficient and that the changing pressure drops of the air filters due to their nonuniform soiling should be taken into account. The novelty of this paper is in proposed method of considering these leaks in the Wells-Riley model, widely used in the literature for airborne transmission of infectious diseases, including the leakage correction factor fhrleak (outdoor fresh air correction factor) based on EATR (exhaust air transfer ratio). Using the proposed method, for typical rooms, on the example of the SARS-CoV-2 virus and its Delta and Omicron variants, it is shown that considering leaks in heat recovery systems in AHU increases the probability of pathogen transmission. The highest increase in the absolute value of the probability of infection is observed in the single office scenario (4.1%) and in the auditorium with a sick speaker scenario (2.7%). The highest increase in reproduction number is observed in the auditorium with a sick speaker scenario (2.69). Such significant changes in reproduction number, including its change from R < 1.0 to R > 1.0 (auditorium with sick speaker for Delta variant of the virus), are crucial from the point of view of considering event scenarios; they slow down or accelerate the pandemic.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Dynamics of charged aerosols relevant to transmission of airborne infections
    Karimov, A. R.
    Stenflo, L.
    Yu, M. Y.
    PHYSICA SCRIPTA, 2022, 97 (08)
  • [32] The air as harbinger of infections in critical care units
    Deepa, S.
    Abishek, M. U.
    Venkatesha, D.
    MEDICAL SCIENCE, 2014, 8-9 (28-35) : 8 - 13
  • [33] A fuzzy sensor for measuring the mixed air temperature in air-handling units
    Lee, PS
    Dexter, AL
    MEASUREMENT, 2005, 37 (01) : 83 - 93
  • [34] ABCS OF AIR CONDITIONING .9. AIR MOVING DEVICES (B) AIR HANDLING UNITS
    GOSLING, CT
    MODERN REFRIGERATION AND AIR CONDITIONING, 1969, 72 (860): : 34 - &
  • [35] Optimization strategy for air handling units in spacecraft launching site
    Cong, Hua
    Yang, Yongli
    Jiang, Pengcheng
    Feng, Fuzhou
    Zhang, Hongxing
    Li, Yaokai
    Hao, Jinfeng
    APPLIED THERMAL ENGINEERING, 2016, 109 : 678 - 684
  • [36] A new sequencing control strategy for air-handling units
    Seem, JE
    Park, C
    House, JM
    HVAC&R RESEARCH, 1999, 5 (01): : 35 - 58
  • [37] Automated proactive techniques for commissioning air-handling units
    Katipamula, S
    Brambley, MR
    Luskay, L
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2003, 125 (03): : 282 - 291
  • [38] THE EFFECT OF MALFUNCTIONS IN AIR HANDLING UNITS ON ENERGY AND EXERGY EFFICIENCY
    Ceylan, Ilhan
    Yildiz, Gokhan
    Gurel, Ali Etem
    Ergun, Alper
    Tosun, Abdulkerim
    HEAT TRANSFER RESEARCH, 2020, 51 (11) : 1007 - 1028
  • [39] Fresh air-handling units: Comparison and design guide
    Berbari, George J.
    Shakkour, Sleiman
    Hashem, Fadi
    ASHRAE JOURNAL, 2007, 49 (01) : 34 - +
  • [40] Workplace air quality at explosive material manufacturing and handling units
    Kannan, G. K.
    Kapoor, J. C.
    DEFENCE SCIENCE JOURNAL, 2006, 56 (04) : 637 - 647