Evaluation of the effects of wiping decontamination for filter cartridges of elastomeric half-mask respirators (EHMRs)

被引:1
|
作者
Vo, Evanly [1 ]
Horvatin, Matthew [1 ]
Zhuang, Ziqing [1 ]
McClain, Caitlin [1 ]
Streeter, Rebecca [2 ]
Brannen, Jeremy [1 ]
Suhon, Nichole L. [1 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
[2] Bluesphere Bio, Pittsburgh, PA USA
关键词
EHMR P100 filter cartridges; Quaternary ammonium wipes; Sodium hypochlorite wipes; Filter performance; EHMR reuse;
D O I
10.1016/j.ajic.2023.05.013
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: A major concern among health care experts is a shortage of N95 filtering facepiece respirators during a pandemic. If the supply of N95 filtering facepiece respirators becomes limited, reusable elastomeric half -mask respirators (EHMRs) may be used to protect health care workers. The focus of this study was to evaluate the effects on the filter performance of wiping decontamination for EHMR P100 filter cartridges. Methods: The filter cartridge exterior of EHMR Honeywell, Moldex, and Mine Safety Appliance (MSA) models was wiped using quaternary ammonium and sodium hypochlorite wipes. These filter cartridge properties were assessed including observational analysis and filter performance tests. These wiping and assessing procedures were repeated after each set of wiping cycles (50, 100, 150, 200, and 400 cycles) to determine the effects of wiping decontamination. Results: For sodium hypochlorite wipes, Honeywell, Moldex, and MSA models passed the National Institute for Occupational Safety and Health (NIOSH) liquid particulate penetration criteria for all wiping cycles from 50 to 400 (penetrations < 0.014%). For quaternary ammonium wipes, filter penetrations of Moldex failed (penetrations > 0.03%) after 150 cycles, while the filter penetrations of Honeywell and MSA passed for all wiping cycles (penetrations <= 0.013%). Conclusions: Wiping decontamination methods using sodium hypochlorite and quaternary ammonium wipes could be considered promising decontamination candidates for Honeywell, Moldex, and MSA reuse, except for the wiping number selection for Moldex (< 150 cycles) when using the quaternary ammonium wipe. Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 36 条
  • [1] Healthcare Workers' Disinfection Practices for Elastomeric Half-mask Respirators
    Thurman, P.
    Zhuang, E.
    Chen, H.
    McDiarmid, M.
    Chalikonda, S.
    Angelilli, S.
    Waltenbaugh, H.
    Napoli, M.
    Fernando, R.
    Haas, E.
    Mcclain, C.
    Sietsema, M.
    Hines, S. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [2] Provider experiences with daily use of elastomeric half-mask respirators in health care
    Lane, Morgan
    Pompeii, Lisa
    Rios, Janelle
    Benavides, Elisa
    Kasbaum, Marie
    Patlovich, Scott
    Ostrosky-Zeichner, Luis
    Hornbeck, Adam
    McClain, Caitlin
    Fernando, Rohan
    Sietsema, Margaret
    Kraft, Colleen
    AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (07) : 745 - 750
  • [3] Wipe Disinfection of Reusable Elastomeric Half-Mask Respirators for Health Care Use
    Erukunuakpor, Kimberly
    Nielsen, Karen Emily
    Lane, Morgan A.
    Hornbeck, Adam
    Mcclain, Caitlin
    Fernando, Rohan
    Sietsema, Margaret
    Kraft, Colleen S.
    Casanova, Lisa M.
    WORKPLACE HEALTH & SAFETY, 2024, 72 (12) : 550 - 558
  • [4] Effect of design of half-mask respirators on their key qualities
    Golinko, V.
    Cheberiachko, S.
    Cheberiachko, Y.
    NEW TECHNIQUES AND TECHNOLOGIES IN MINING, 2010, : 151 - 155
  • [5] THE ASSIGNED PROTECTION FACTOR OF 10 FOR HALF-MASK RESPIRATORS
    NELSON, TJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1995, 56 (07): : 717 - 724
  • [6] Facial dimensions and predictors of fit for half-mask respirators in Koreans
    Han, DH
    Choi, KL
    AIHA JOURNAL, 2003, 64 (06): : 815 - 822
  • [7] Training and Fit Testing of Health Care Personnel for Reusable Elastomeric Half-Mask Respirators Compared With Disposable N95 Respirators
    Pompeii, Lisa A.
    Kraft, Colleen S.
    Brownsword, Erik A.
    Lane, Morgan A.
    Benavides, Elisa
    Rios, Janelle
    Radonovich, Lewis J., Jr.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2020, 323 (18): : 1849 - 1852
  • [8] Physiologic Effects of Elastomeric Half-Mask Respirator Use with or Without a Surgical Mask in Healthcare Workers
    Zhuang, E.
    Thurman, P.
    Kolesnik, O.
    Hines, S. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [9] Effectiveness of Elastomeric Half-Mask Respirators vs N95 Filtering Facepiece Respirators During Simulated Resuscitation A Nonrandomized Controlled Trial
    Barros, Andrew J.
    Sifri, Costi D.
    Bell, Taison D.
    Eby, Joshua C.
    Enfield, Kyle B.
    JAMA NETWORK OPEN, 2021, 4 (03)
  • [10] FIELD TESTING OF THROW-AWAY HALF-MASK DUST RESPIRATORS
    HARRIS, HE
    DESIEGHARDT, WC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (09): : 546 - 551