THE ASSIGNED PROTECTION FACTOR OF 10 FOR HALF-MASK RESPIRATORS

被引:0
|
作者
NELSON, TJ
机构
来源
关键词
D O I
10.1202/0002-8894(1995)056<0717:TAPFOF>2.0.CO;2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A number of researchers have published or presented papers on workplace protection factor (WPF) studies involving half-mask respirators. Individually, each study contains a relatively small amount of data, generally less than 25 data points for any single respirator. Because of the small amount of data, any attempt to quantify the result statistically does not provide useful information on the low end of the distribution of WPFs. Several studies on half-mask respirators were combined to yield a data set with 390 observations. Of these WPF data, 1.5% were less than 10, the best estimate of the 5th percentile was 13, with a 95% confidence interval of 10 to 18. Differences between the mean WPF based on the type of filter were found, but no difference was found between the mean performance of elastomeric and disposable respirators equipped with dust/mist and dust/fume/mist filters.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [1] VARIABILITY IN PROTECTION AFFORDED BY HALF-MASK RESPIRATORS AGAINST STYRENE EXPOSURE IN THE FIELD
    GALVIN, K
    SELVIN, S
    SPEAR, RC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1990, 51 (12): : 625 - 631
  • [2] Effect of design of half-mask respirators on their key qualities
    Golinko, V.
    Cheberiachko, S.
    Cheberiachko, Y.
    NEW TECHNIQUES AND TECHNOLOGIES IN MINING, 2010, : 151 - 155
  • [3] Facial dimensions and predictors of fit for half-mask respirators in Koreans
    Han, DH
    Choi, KL
    AIHA JOURNAL, 2003, 64 (06): : 815 - 822
  • [4] DETERMINATION OF PROGRAM PROTECTION FACTORS FOR HALF-MASK RESPIRATORS USED AT A MINERAL SANDS SEPARATION PLANT
    HEWSON, GS
    RALPH, MI
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1992, 53 (11): : 713 - 720
  • [5] Healthcare Workers' Disinfection Practices for Elastomeric Half-mask Respirators
    Thurman, P.
    Zhuang, E.
    Chen, H.
    McDiarmid, M.
    Chalikonda, S.
    Angelilli, S.
    Waltenbaugh, H.
    Napoli, M.
    Fernando, R.
    Haas, E.
    Mcclain, C.
    Sietsema, M.
    Hines, S. E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [6] FIELD TESTING OF THROW-AWAY HALF-MASK DUST RESPIRATORS
    HARRIS, HE
    DESIEGHARDT, WC
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1974, 35 (09): : 546 - 551
  • [7] Provider experiences with daily use of elastomeric half-mask respirators in health care
    Lane, Morgan
    Pompeii, Lisa
    Rios, Janelle
    Benavides, Elisa
    Kasbaum, Marie
    Patlovich, Scott
    Ostrosky-Zeichner, Luis
    Hornbeck, Adam
    McClain, Caitlin
    Fernando, Rohan
    Sietsema, Margaret
    Kraft, Colleen
    AMERICAN JOURNAL OF INFECTION CONTROL, 2024, 52 (07) : 745 - 750
  • [8] Wipe Disinfection of Reusable Elastomeric Half-Mask Respirators for Health Care Use
    Erukunuakpor, Kimberly
    Nielsen, Karen Emily
    Lane, Morgan A.
    Hornbeck, Adam
    Mcclain, Caitlin
    Fernando, Rohan
    Sietsema, Margaret
    Kraft, Colleen S.
    Casanova, Lisa M.
    WORKPLACE HEALTH & SAFETY, 2024, 72 (12) : 550 - 558
  • [9] MEASUREMENT OF PROTECTION FACTORS OF CHEMICAL CARTRIDGE, HALF-MASK RESPIRATORS UNDER WORKING-CONDITIONS IN A COPPER SMELTER
    MOORE, DE
    SMITH, TJ
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1976, 37 (08): : 453 - 458
  • [10] Total outward leakage of half-mask respirators and surgical masks used for source control
    Myers, Warren R.
    Yang, Weihua
    Ryan, Kenneth J.
    Bergman, Michael S.
    Fisher, Edward M.
    Soo, Jhy-Charm
    Zhuang, Ziqing
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2023, 20 (12) : 610 - 620