Evaluation of the effects of wiping decontamination for filter cartridges of elastomeric half-mask respirators (EHMRs)

被引:1
|
作者
Vo, Evanly [1 ]
Horvatin, Matthew [1 ]
Zhuang, Ziqing [1 ]
McClain, Caitlin [1 ]
Streeter, Rebecca [2 ]
Brannen, Jeremy [1 ]
Suhon, Nichole L. [1 ]
机构
[1] NIOSH, Natl Personal Protect Technol Lab, 626 Cochrans Mill Rd, Pittsburgh, PA 15236 USA
[2] Bluesphere Bio, Pittsburgh, PA USA
关键词
EHMR P100 filter cartridges; Quaternary ammonium wipes; Sodium hypochlorite wipes; Filter performance; EHMR reuse;
D O I
10.1016/j.ajic.2023.05.013
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: A major concern among health care experts is a shortage of N95 filtering facepiece respirators during a pandemic. If the supply of N95 filtering facepiece respirators becomes limited, reusable elastomeric half -mask respirators (EHMRs) may be used to protect health care workers. The focus of this study was to evaluate the effects on the filter performance of wiping decontamination for EHMR P100 filter cartridges. Methods: The filter cartridge exterior of EHMR Honeywell, Moldex, and Mine Safety Appliance (MSA) models was wiped using quaternary ammonium and sodium hypochlorite wipes. These filter cartridge properties were assessed including observational analysis and filter performance tests. These wiping and assessing procedures were repeated after each set of wiping cycles (50, 100, 150, 200, and 400 cycles) to determine the effects of wiping decontamination. Results: For sodium hypochlorite wipes, Honeywell, Moldex, and MSA models passed the National Institute for Occupational Safety and Health (NIOSH) liquid particulate penetration criteria for all wiping cycles from 50 to 400 (penetrations < 0.014%). For quaternary ammonium wipes, filter penetrations of Moldex failed (penetrations > 0.03%) after 150 cycles, while the filter penetrations of Honeywell and MSA passed for all wiping cycles (penetrations <= 0.013%). Conclusions: Wiping decontamination methods using sodium hypochlorite and quaternary ammonium wipes could be considered promising decontamination candidates for Honeywell, Moldex, and MSA reuse, except for the wiping number selection for Moldex (< 150 cycles) when using the quaternary ammonium wipe. Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc. All rights reserved.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 36 条
  • [31] Health Care Workers' Comfort Ratings for Elastomeric Half Mask Respirators Versus N95® Filtering Facepiece Respirators During the COVID-19 Pandemic
    Pompeii, Lisa
    Rios, Janelle
    Kraft, Colleen S.
    Kasbaum, Marie
    Benavides, Elisa
    Patlovich, Scott J.
    Ostrosky-Zeichner, Luis
    Hornbeck, Adam
    McClain, Caitlin
    Fernando, Rohan D.
    Sietsema, Margaret
    Lane, Morgan
    WORKPLACE HEALTH & SAFETY, 2024, 72 (07) : 261 - 272
  • [32] Filtration evaluation and clinical use of expired elastomeric P-100 filter cartridges during the COVID-19 pandemic
    Patolia, Harsh H.
    Pan, Jin
    Harb, Charbel
    Marr, Linsey C.
    Baffoe-Bonnie, Anthony W.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2021, 42 (03): : 367 - 369
  • [33] Lessons learned in establishing and sustaining elastomeric half mask respirator-based respiratory protection programs: An impact evaluation
    Haas, Emily J.
    Edirisooriya, Mihili
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2025, 22 (03) : 178 - 188
  • [34] Lessons learned in establishing and sustaining elastomeric half mask respirator-based respiratory protection programs: An impact evaluation
    Haas, Emily J.
    Edirisooriya, Mihili
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2024,
  • [35] Filtration evaluation of expired elastomeric P-100 filter cartridges after months of real-world use during the coronavirus disease 2019 (COVID-19) pandemic
    Baffoe-Bonnie, Anthony W.
    Zhang, Kermit Sheng
    Pan, Jin
    Simpkins, Kirsten
    Marr, Linsey C.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2022, 43 (06): : 824 - 825
  • [36] Evaluation of total inward leakage for NIOSH-approved elastomeric half-facepiece, full-facepiece, and powered air-purifying respirators using sodium chloride and corn oil aerosols
    Rengasamy, Samy
    Zhuang, Ziqing
    Lawrence, Robert B.
    Boutin, Brenda
    Yorio, Patrick
    Horvatin, Matthew
    McClain, Caitlin
    Harris, James R.
    Coffey, Christopher
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2021, 18 (07) : 305 - 313