Petroleomics by design of experiments in ESI(±)FT-ICR MS analysis

被引:0
|
作者
Folli, Gabriely S. [1 ]
dos Santos, Lindamara [1 ]
Zanoni, Madson P. [1 ]
Chinelatto Junior, Luiz Silvino [2 ]
Romao, Wanderson [1 ,3 ]
Filgueiras, Paulo R. [1 ]
机构
[1] Fed Univ Espirito Santo UFES, Lab Petrole, BR-29040090 Espirito Santo, ES, Brazil
[2] Petrobras Res Dev & Innovat Ctr CENPES, BR-21941915 Rio De Janeiro, RJ, Brazil
[3] Fed Inst Educ Sci & Technol Espirito Santo IFES, Sci Dept, BR-29106010 Espirito Santo, ES, Brazil
关键词
Design of experiments; Global desirability; Petroleomics; Chemometrics; High resolution; Spectral profile optimization; ION-CYCLOTRON RESONANCE; ICR MASS-SPECTROMETRY; COLLISION-INDUCED DISSOCIATION; PARTIAL LEAST-SQUARES; TOTAL ACID NUMBER; ELECTROSPRAY-IONIZATION; HEAVY PETROLEUM; CRUDE OILS; ULTRAHIGH-RESOLUTION; MOLECULAR CHARACTERIZATION;
D O I
10.1016/j.fuel.2023.129391
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
\The Fourier Transform Ion Cyclotron Resonance mass spectrometer (FT-ICR MS) is an efficient and widely used analytical instrument for characterizing complex organic mixtures at the molecular level. The Electrospray ionization (ESI) source is commonly used for identifying heteroatomic compounds (N, O, S) in crude oil. The high complexity of the sample provides a wealth of information, and therefore, processing and visualization programs are used to facilitate data interpretation. Several experimental configurations of parameters exist for the acquisition of ESI(+)FT-ICR MS and ESI(-)FT-ICR MS of crude oils. In this context, the design of experiments can help obtain optimal test conditions. The objective of this work was to identify the most significant experimental parameters among the 11 available (concentration, skimmer, time of flight (TOF), flow rate, ion accumulation time (IAT), accumulated scans (scans), dry temperature, capillary, dry gas, nebulizer, and collision voltage (CV)) for the acquisition of ESI(+/-)FT-ICR MS in Petroleomics using design of experiments by Plackett Burman and full design. Global desirability was used as a response parameter obtained from MS data (resolution, signal-to-noise ratio, signal-to-charge ratio signal with highest absolute intensity, total signals, low mass error, and high mass error). Additionally, responses from the mass spectra processing program were also used (the number of molecular formulas, molecular formulas of the majority class, average error, assignment percentage, amount of DBE in the plot of DBE versus carbon number (CN), and the relationship between the number of zero intensities and the number of DBE values in the plot of DBE versus CN). The study found that concentration and flow rate were the most significant experimental parameters for ESI(+), while for ESI(-), TOF and CV were the most significant experimental parameters. Lower concentration (0.1-0.5 mg/mL) and higher flowrate (5-6 mu L/min) improved the desirability by ESI(+), higher values of CV (50 V) improved the desirability by ESI(-) for crude oil analysis.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Using ESI FT-ICR MS to Characterize Dissolved Organic Matter in Salt Lakes with Different Salinity
    Xu, Wei
    Gao, Qang
    He, Chen
    Shi, Quan
    Hou, Zheng-Qng
    Zhao, Hua-Zhang
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (20) : 12929 - 12937
  • [32] Separation and characterization of petroleum asphaltene fractions by ESI FT-ICR MS and UV-vis spectrometer
    WANG ShanShan
    YANG Chuang
    XU ChunMing
    ZHAO SuoQi
    SHI Quan
    Science China(Chemistry), 2013, 56 (07) : 856 - 862
  • [33] Transformation of sulfur compounds in two typical atmospheric residues in hydrotreating via ESI FT-ICR MS
    Zhang, Cheng
    Zhang, Ying
    Liu, Mei
    Guan, Yue-Ming
    Yuan, Sheng-Hua
    FUEL, 2020, 281
  • [34] Separation and characterization of petroleum asphaltene fractions by ESI FT-ICR MS and UV-vis spectrometer
    Wang ShanShan
    Yang Chuang
    Xu ChunMing
    Zhao SuoQi
    Shi Quan
    SCIENCE CHINA-CHEMISTRY, 2013, 56 (07) : 856 - 862
  • [35] Separation and characterization of petroleum asphaltene fractions by ESI FT-ICR MS and UV-vis spectrometer
    ShanShan Wang
    Chuang Yang
    ChunMing Xu
    SuoQi Zhao
    Quan Shi
    Science China Chemistry, 2013, 56 : 856 - 862
  • [36] Application of FT-ICR MS Equipped with Quadrupole Detection for Analysis of Crude Oil
    Cho, Eunji
    Witt, Matthias
    Hur, Manhoi
    Jung, Maeng-Joon
    Kim, Sunghwan
    ANALYTICAL CHEMISTRY, 2017, 89 (22) : 12101 - 12107
  • [37] Plant metabolomic analyses by FT-ICR/MS, GC/MS, and LC/MS
    Morikawa, T
    Oikawa, A
    Wadano, A
    Yano, K
    Sakurai, N
    Suzuki, H
    Saito, K
    Shibata, D
    Ohta, D
    PLANT AND CELL PHYSIOLOGY, 2004, 45 : S206 - S206
  • [38] Use of multiplex network analysis in ESI(±) FT-ICR MS data fusion to differentiate crude oils from the same basin
    Lucena, Pedro G. C.
    Carregosa, Jhonattas C.
    Eberlin, Marcos N.
    Wisniewski, Alberto, Jr.
    Santos, Jandyson M.
    FUEL, 2025, 384
  • [39] Optimisation of LDI(+)-FT-ICR MS analysis of asphaltenes to prevent the formation of fullerenes
    Fonseca, Victor R.
    Folli, Gabriely S.
    Souza, Lindamara M.
    Pereira, Thieres M. C.
    Lima, Guilherme S. V.
    Viegas, Carla C. B.
    Chinelatto, Luiz S.
    Neto, Alvaro C.
    Filgueiras, Paulo R.
    Lacerda, Valdemar
    Romao, Wanderson
    FUEL, 2023, 347
  • [40] Heavy-Oil Surrogate Formulation Based on FT-ICR MS Analysis
    Guevara, Edwin
    Alabbad, Mohammed
    Chatakonda, Obulesu
    Kloosterman, Jeffrey W.
    Middaugh, Joshua
    Zhang, Wen
    Emwas, Abdul-Hamid
    Sarathy, S. Mani
    ENERGY & FUELS, 2023, 37 (21) : 16354 - 16367