Petroleomics by design of experiments in ESI(±)FT-ICR MS analysis

被引:0
|
作者
Folli, Gabriely S. [1 ]
dos Santos, Lindamara [1 ]
Zanoni, Madson P. [1 ]
Chinelatto Junior, Luiz Silvino [2 ]
Romao, Wanderson [1 ,3 ]
Filgueiras, Paulo R. [1 ]
机构
[1] Fed Univ Espirito Santo UFES, Lab Petrole, BR-29040090 Espirito Santo, ES, Brazil
[2] Petrobras Res Dev & Innovat Ctr CENPES, BR-21941915 Rio De Janeiro, RJ, Brazil
[3] Fed Inst Educ Sci & Technol Espirito Santo IFES, Sci Dept, BR-29106010 Espirito Santo, ES, Brazil
关键词
Design of experiments; Global desirability; Petroleomics; Chemometrics; High resolution; Spectral profile optimization; ION-CYCLOTRON RESONANCE; ICR MASS-SPECTROMETRY; COLLISION-INDUCED DISSOCIATION; PARTIAL LEAST-SQUARES; TOTAL ACID NUMBER; ELECTROSPRAY-IONIZATION; HEAVY PETROLEUM; CRUDE OILS; ULTRAHIGH-RESOLUTION; MOLECULAR CHARACTERIZATION;
D O I
10.1016/j.fuel.2023.129391
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
\The Fourier Transform Ion Cyclotron Resonance mass spectrometer (FT-ICR MS) is an efficient and widely used analytical instrument for characterizing complex organic mixtures at the molecular level. The Electrospray ionization (ESI) source is commonly used for identifying heteroatomic compounds (N, O, S) in crude oil. The high complexity of the sample provides a wealth of information, and therefore, processing and visualization programs are used to facilitate data interpretation. Several experimental configurations of parameters exist for the acquisition of ESI(+)FT-ICR MS and ESI(-)FT-ICR MS of crude oils. In this context, the design of experiments can help obtain optimal test conditions. The objective of this work was to identify the most significant experimental parameters among the 11 available (concentration, skimmer, time of flight (TOF), flow rate, ion accumulation time (IAT), accumulated scans (scans), dry temperature, capillary, dry gas, nebulizer, and collision voltage (CV)) for the acquisition of ESI(+/-)FT-ICR MS in Petroleomics using design of experiments by Plackett Burman and full design. Global desirability was used as a response parameter obtained from MS data (resolution, signal-to-noise ratio, signal-to-charge ratio signal with highest absolute intensity, total signals, low mass error, and high mass error). Additionally, responses from the mass spectra processing program were also used (the number of molecular formulas, molecular formulas of the majority class, average error, assignment percentage, amount of DBE in the plot of DBE versus carbon number (CN), and the relationship between the number of zero intensities and the number of DBE values in the plot of DBE versus CN). The study found that concentration and flow rate were the most significant experimental parameters for ESI(+), while for ESI(-), TOF and CV were the most significant experimental parameters. Lower concentration (0.1-0.5 mg/mL) and higher flowrate (5-6 mu L/min) improved the desirability by ESI(+), higher values of CV (50 V) improved the desirability by ESI(-) for crude oil analysis.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Analysis of extractable basic nitrogen compounds in Buliangou subbituminous coal by positive-ion ESI FT-ICR MS
    Kong, Jiao
    Wei, Xian-Yong
    Yan, Hong-Lei
    Li, Zhan-Ku
    Zhao, Mei-Xia
    Li, Yan
    Zong, Zhi-Min
    FUEL, 2015, 159 : 385 - 391
  • [22] Molecular composition analysis of lubricant base oils by using RICO redox derivatization followed by ESI FT-ICR MS
    Ma, Sutian
    Hsu, Chang
    Zhou, Yasong
    Shi, Quan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [23] Analysis of the microstructure of high viscosity components in Tahe ultra heavy oil based on the combination of ESI (±) FT-ICR/MS
    Yang, Zu-guo
    Zhao, Hong-yu
    Guo, Ji-xiang
    Chen, Yong
    FUEL, 2024, 368
  • [24] Application of ESI FT-ICR MS to molecular-level characterization of NOM: A progress report on data analysis and interpretation
    Kujawinski, EB
    D Behn, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1774 - U1775
  • [25] Separation and characterization of petroleum asphaltene fractions by ESI FT-ICR MS and UV-vis spectrometer
    WANG ShanShan
    YANG Chuang
    XU ChunMing
    ZHAO SuoQi
    SHI Quan
    Science China(Chemistry), 2013, (07) : 856 - 862
  • [26] Origin of polar organic sulfur compounds in immature crude oils revealed by ESI FT-ICR MS
    Liu, Weimin
    Liao, Yuhong
    Shi, Quan
    Hsu, Chang Samuel
    Jiang, Bin
    Peng, Ping'an
    ORGANIC GEOCHEMISTRY, 2018, 121 : 36 - 47
  • [27] Asphaltenes subfractions characterization and calculation of their solubility parameter using ESI(-) FT-ICR MS: Part II
    Pinto, Fernanda E.
    Fonseca, Victor R.
    Souza, Lindamara M.
    Terra, Luciana A.
    Subramanian, Sreedhar
    Simon, Sebastien
    Sjoblom, Johan
    Pereira, Thieres M.
    Lacerda, Valdemar
    Romao, Wanderson
    FUEL, 2022, 312
  • [28] Characterization of petroleum samples by GC/FT-ICR MS
    Solouki, Touradj
    Rasaiah, Jayendran C.
    Szulejko, J. E.
    Silwal, Indira K.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [29] Application of FT-ICR MS for the Study of Protein Complexes
    Liu, Yaqin
    Pan, Yuanjiang
    APPLIED SPECTROSCOPY REVIEWS, 2009, 44 (03) : 231 - 244
  • [30] Observation of heterogeneous gene products by FT-ICR MS
    Robertson, Duncan H. L.
    Wong, Stephen C. C.
    Beynon, Robert J.
    Hurst, Jane L.
    Gaskell, Simon J.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (01) : 103 - 110