Petroleomics by design of experiments in ESI(±)FT-ICR MS analysis

被引:0
|
作者
Folli, Gabriely S. [1 ]
dos Santos, Lindamara [1 ]
Zanoni, Madson P. [1 ]
Chinelatto Junior, Luiz Silvino [2 ]
Romao, Wanderson [1 ,3 ]
Filgueiras, Paulo R. [1 ]
机构
[1] Fed Univ Espirito Santo UFES, Lab Petrole, BR-29040090 Espirito Santo, ES, Brazil
[2] Petrobras Res Dev & Innovat Ctr CENPES, BR-21941915 Rio De Janeiro, RJ, Brazil
[3] Fed Inst Educ Sci & Technol Espirito Santo IFES, Sci Dept, BR-29106010 Espirito Santo, ES, Brazil
关键词
Design of experiments; Global desirability; Petroleomics; Chemometrics; High resolution; Spectral profile optimization; ION-CYCLOTRON RESONANCE; ICR MASS-SPECTROMETRY; COLLISION-INDUCED DISSOCIATION; PARTIAL LEAST-SQUARES; TOTAL ACID NUMBER; ELECTROSPRAY-IONIZATION; HEAVY PETROLEUM; CRUDE OILS; ULTRAHIGH-RESOLUTION; MOLECULAR CHARACTERIZATION;
D O I
10.1016/j.fuel.2023.129391
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
\The Fourier Transform Ion Cyclotron Resonance mass spectrometer (FT-ICR MS) is an efficient and widely used analytical instrument for characterizing complex organic mixtures at the molecular level. The Electrospray ionization (ESI) source is commonly used for identifying heteroatomic compounds (N, O, S) in crude oil. The high complexity of the sample provides a wealth of information, and therefore, processing and visualization programs are used to facilitate data interpretation. Several experimental configurations of parameters exist for the acquisition of ESI(+)FT-ICR MS and ESI(-)FT-ICR MS of crude oils. In this context, the design of experiments can help obtain optimal test conditions. The objective of this work was to identify the most significant experimental parameters among the 11 available (concentration, skimmer, time of flight (TOF), flow rate, ion accumulation time (IAT), accumulated scans (scans), dry temperature, capillary, dry gas, nebulizer, and collision voltage (CV)) for the acquisition of ESI(+/-)FT-ICR MS in Petroleomics using design of experiments by Plackett Burman and full design. Global desirability was used as a response parameter obtained from MS data (resolution, signal-to-noise ratio, signal-to-charge ratio signal with highest absolute intensity, total signals, low mass error, and high mass error). Additionally, responses from the mass spectra processing program were also used (the number of molecular formulas, molecular formulas of the majority class, average error, assignment percentage, amount of DBE in the plot of DBE versus carbon number (CN), and the relationship between the number of zero intensities and the number of DBE values in the plot of DBE versus CN). The study found that concentration and flow rate were the most significant experimental parameters for ESI(+), while for ESI(-), TOF and CV were the most significant experimental parameters. Lower concentration (0.1-0.5 mg/mL) and higher flowrate (5-6 mu L/min) improved the desirability by ESI(+), higher values of CV (50 V) improved the desirability by ESI(-) for crude oil analysis.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Petroleomics by EASI(±) FT-ICR MS
    Corilo, Yuri E.
    Vaz, Boniek G.
    Simas, Rosineide C.
    Lopes Nascimento, Heliara D.
    Klitzke, Clecio F.
    Pereira, Rosana C. L.
    Bastos, Wagner L.
    Santos Neto, Eugenio V.
    Rodgers, Ryan P.
    Eberlin, Marcos N.
    ANALYTICAL CHEMISTRY, 2010, 82 (10) : 3990 - 3996
  • [2] Petroleomics: ESI FT-ICR MS identification of hydrotreatment resistant neutral and acidic nitrogen species in crude oil.
    Rodgers, RP
    Klein, GC
    Marshall, AG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U535 - U535
  • [3] DEVELOPMENTS IN FT-ICR MS INSTRUMENTATION, IONIZATION TECHNIQUES, AND DATA INTERPRETATION METHODS FOR PETROLEOMICS
    Cho, Yunju
    Ahmed, Arif
    Islam, Annana
    Kim, Sunghwan
    MASS SPECTROMETRY REVIEWS, 2015, 34 (02) : 248 - 263
  • [4] Chemometric Unmixing of Petroleum Mixtures by Negative Ion ESI FT-ICR MS Analysis
    Jiang, Bin
    Zhan, Zhao-Wen
    Shi, Quan
    Liao, Yuhong
    Zou, Yan-Rong
    Tian, Yankuan
    Peng, Ping'an
    ANALYTICAL CHEMISTRY, 2019, 91 (03) : 2209 - 2215
  • [5] Metabolic profiling analysis using FT-ICR MS
    Oikawa, A
    Kimura, A
    Nakamura, Y
    Sakurai, N
    Suzuki, H
    Saito, K
    Shibata, D
    Kanaya, S
    Ohta, D
    PLANT AND CELL PHYSIOLOGY, 2006, 47 : S24 - S24
  • [6] FT-ICR MS optimization for the analysis of intact proteins
    Tolmachev, Aleksey V.
    Robinson, Errol W.
    Wu, Si
    Pasa-Tolic, Ljiljana
    Smith, Richard D.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2009, 287 (1-3) : 32 - 38
  • [7] ESI FT-ICR mass spectral analysis of coal liquefaction products
    Wu, ZG
    Rodgers, RP
    Marshall, AG
    FUEL, 2005, 84 (14-15) : 1790 - 1797
  • [8] Characterization of RDX and HMX explosive adduct ions using ESI FT-ICR MS
    Lee, Jihyeon
    Kim, Min Sun
    Kim, Hyun Sik
    Choe, Yoong-Kee
    Cho, Soo Gyeong
    Goh, Eun Mee
    Kim, Jeongkwon
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (04):
  • [9] Study of Naphthenic Acidity and Corrosivity of Brazilian Crude Oils by ESI(-) FT-ICR MS
    Martins, Laercio L.
    da Silva, Pollyana F.
    da Cruz, Georgiana F.
    Pudenzi, Marcos A.
    Eberlin, Marcos N.
    Riehl, Carlos Alberto da S.
    Souza, Djalma
    REVISTA VIRTUAL DE QUIMICA, 2018, 10 (03) : 625 - 640
  • [10] Tracking Catalytic Esterification of Naphthenic Acids in Crude Oil by ESI FT-ICR MS
    Li Xiaohui
    Wu Bencheng
    Zhu Jianhua
    Tao Xiujuan
    ChinaPetroleumProcessing&PetrochemicalTechnology, 2016, 18 (03) : 57 - 65