Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup

被引:3
|
作者
Reimer, R. P. [1 ,2 ]
Zaytoun, H. [1 ,2 ]
Klein, K. [1 ,2 ]
Sonnabend, K. [1 ,2 ,3 ]
Lennartz, S. [1 ,2 ]
Zopfs, D. [1 ,2 ]
Heidenreich, A. [2 ,4 ]
Maintz, D. [1 ,2 ]
Hokamp, N. Grosse [1 ,2 ]
机构
[1] Univ Cologne, Fac Med, Dept Diagnost & Intervent Radiol, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Cologne, Univ Hosp Cologne, Kerpener St 62, D-50937 Cologne, Germany
[3] Philips GmbH Market DACH, Hamburg, Germany
[4] Univ Cologne, Fac Med, Dept Urol, Cologne, Germany
关键词
Contrast media; Tomography; spiral computed; Kidney calculi; Radiation dosage; ENERGY CT UROGRAPHY; STATISTICAL ITERATIVE RECONSTRUCTION; IODINE QUANTIFICATION; UROLITHIASIS; ATTENUATION; DIAGNOSIS;
D O I
10.1007/s00330-022-09261-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To systematically investigate the usability of virtual non-contrast reconstructions (VNC) derived from dual-layer CT (DLCT) for detection and size measurements of kidney stones with regards to different degrees of surrounding iodine-induced attenuation and radiation dose. Methods Ninety-two kidney stones of varying size (3-14 mm) and composition were placed in a phantom filled with different contrast media/water mixtures exhibiting specific iodine-induced attenuation (0-1500 HU). DLCT-scans were acquired using CTDIvol of 2 mGy and 10 mGy. Conventional images (CI) and VNC0H-1500HU were reconstructed. Reference stone size was determined using a digital caliper (Man-M). Visibility and stone size were assessed. Statistical analysis was performed using the McNemar test, Wilcoxon test, and the coefficient of determination. Results All stones were visible on CI0HU and VNC200HU. Starting at VNC400 HU, the detection rate decreased with increasing HU and was significantly lower as compared to CI0HU on VNC >= 600HU (100.0 vs. 94.0%, p < 0.05). The overall detection rate was higher using 10 mGy as compared to 2 mGy protocol (87.9 vs. 81.8%; p < 0.001). Stone size was significantly overestimated on all VNC compared to Man-M (7.0 +/- 3.5 vs. 6.6 +/- 2.8 mm, p < 0.001). Again, the 10 mGy protocol tended to show a better correlation with Man-M as compared to 2 mGy protocol (R-2 = 0.39-0.68 vs. R-2 = 0.31-0.57). Conclusions Detection and size measurements of kidney stones surrounded by contrast media on VNC are feasible. The detection rate of kidney stones decreases with increasing iodine-induced attenuation and with decreasing radiation dose as well as stone size, while remaining comparable to CI0HU on VNC (<= 400 HU).
引用
收藏
页码:2995 / 3003
页数:9
相关论文
共 28 条
  • [11] Dual-Energy Computed Tomography in Stroke Imaging: Value of Virtual Non-Contrast Images for Detection of the Hyperdense Artery Sign
    Winklhofer, S.
    De Martini, V.
    Nern, Ch
    Blume, I.
    Wegener, S.
    Pangalu, A.
    Valavanis, A.
    Alkadhi, H.
    Guggenberger, R.
    SWISS MEDICAL WEEKLY, 2016, 146 : 172S - 173S
  • [12] Feasibility and accuracy of coronary artery calcium score on virtual non-contrast images derived from a dual-layer spectral detector CT: A retrospective multicenter study
    Yang, Panpan
    Zhao, Ren
    Deng, Wei
    An, Shutian
    Li, Yuguo
    Sheng, Mao
    Chen, Xingbiao
    Qian, Yingfeng
    Yu, Yongqiang
    Mu, Dan
    Wang, Yining
    Li, Xiaohu
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [13] Virtual Noncontrast Images Derived From Contrast-Enhanced Dual-Layer Spectral Abdominal Computed Tomography: A Pilot Study Between Pediatric and Adult Scans
    Azuma, Minako
    Nakada, Hiroshi
    Khant, Zaw Aung
    Kimura, Aya
    Hirai, Toshinori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (01) : 71 - 77
  • [14] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Felix G. Gassert
    Claudio E. Schacky
    Christina Müller-Leisse
    Florian T. Gassert
    Gregor Pahn
    Karl-Ludwig Laugwitz
    Marcus R. Makowski
    Jonathan Nadjiri
    European Radiology, 2021, 31 : 6193 - 6199
  • [15] Calcium scoring using virtual non-contrast images from a dual-layer spectral detector CT: comparison to true non-contrast data and evaluation of proportionality factor in a large patient collective
    Gassert, Felix G.
    Schacky, Claudio E.
    Mueller-Leisse, Christina
    Gassert, Florian T.
    Pahn, Gregor
    Laugwitz, Karl-Ludwig
    Makowski, Marcus R.
    Nadjiri, Jonathan
    EUROPEAN RADIOLOGY, 2021, 31 (08) : 6193 - 6199
  • [16] Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection
    Bae, Jae Seok
    Lee, Dong Ho
    Joo, Ijin
    Jeon, Sun Kyung
    Han, Joon Koo
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 116 : 34 - 40
  • [17] Improvements of diagnostic accuracy and visualization of vertebral metastasis using multi-level virtual non-calcium reconstructions from dual-layer spectral detector computed tomography
    N. Abdullayev
    N. Große Hokamp
    S. Lennartz
    J. A. Holz
    Z. Romman
    G. Pahn
    V. Neuhaus
    D. Maintz
    B. Krug
    J. Borggrefe
    European Radiology, 2019, 29 : 5941 - 5949
  • [18] Improvements of diagnostic accuracy and visualization of vertebral metastasis using multi-level virtual non-calcium reconstructions from dual-layer spectral detector computed tomography
    Abdullayev, N.
    Hokamp, N. Grosse
    Lennartz, S.
    Holz, J. A.
    Romman, Z.
    Pahn, G.
    Neuhaus, V
    Maintz, D.
    Krug, B.
    Borggrefe, J.
    EUROPEAN RADIOLOGY, 2019, 29 (11) : 5941 - 5949
  • [19] Comparative study of true and virtual non-contrast imaging generated from dual-layer spectral CT in patients with upper aerodigestive tract cancer
    Mingkwansook, Varalee
    Puwametwongsa, Krittiya
    Watcharakorn, Arvemas
    Dechasasawat, Thanapat
    POLISH JOURNAL OF RADIOLOGY, 2022, 87 : E678 - E687
  • [20] Photon-Counting Detector CT for Kidney Stone Detection in Excretory Phase CT-Comparison Between Virtual Non-contrast and Virtual Non-iodine Reconstructions in a 3D Printed Kidney Phantom
    Breiding, Philipe S.
    Gomollon, Ana Maria Turrion
    Martini, Katharina
    Nakhostin, Dominik
    Alkadhi, Hatem
    Euler, Andre
    ACADEMIC RADIOLOGY, 2024, 31 (09) : 3650 - 3656