Utilization of virtual non-contrast images derived from dual-energy CT in evaluation of biliary stone disease: Virtual non-contrast image can replace true non-contrast image regarding biliary stone detection

被引:14
|
作者
Bae, Jae Seok [1 ,2 ]
Lee, Dong Ho [1 ,2 ]
Joo, Ijin [1 ,2 ]
Jeon, Sun Kyung [1 ]
Han, Joon Koo [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Coll Med, Dept Radiol, 103 Daehak Ro, Seoul 03080, South Korea
[3] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, 103 Daehak Ro, Seoul 03080, South Korea
关键词
Dual-energy computed tomography; Contrast media; Cholelithiasis; Choledocholithiasis; BILE-DUCT STONES; SPECTRAL COMPUTED-TOMOGRAPHY; NONENHANCED IMAGES; HELICAL CT; GALLSTONES; ACCURACY; CHOLEDOCHOLITHIASIS; DIAGNOSIS; ERCP;
D O I
10.1016/j.ejrad.2019.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare the virtual non-contrast (VNC) images acquired through dual-energy computed tomography (DECT) with the true non-contrast (TNC) images in the detection of biliary stones and to calculate dose reduction by replacing TNC images with VNC images. Methods: Between March 2017 and April 2018, we retrospectively enrolled 75 patients with suspicious biliary disease who underwent dual-source DECT and surgery and/or endoscopic intervention within 2 months from the CT. Biliary stones were present in 45 patients. The sensitivity and specificity for detecting gallstone and common bile duct (CBD) stone were compared between the VNC and TNC using McNemar test. In addition, the possible reduction in radiation dose was calculated. Results: In our study, 37 patients had gallstones, 2 had CBD stones, and 6 had both gallstone and CBD stones. For detection of gallstones, the sensitivity and specificity were 90.7% (39/43) and 87.5% (28/32), respectively, for the TNC images, and 88.4% (38/43) and 90.6% (29/32), respectively, for the VNC images. With respect to CBD stones, the sensitivity and specificity were 87.5% (7/8) and 98.5% (66/67), respectively, for the TNC images, and 75.0% (6/8) and 100% (67/67), respectively, for the VNC images. There was no significant difference in the sensitivity and specificity between each image set (P > 0.05). The radiation dose reduction of 22.4 +/- 1.3% is expected by omitting TNC images. Conclusions: The VNC images derived from DECT were comparable to the TNC images for the detection of biliary stones and may replace the TNC images to reduce radiation dose.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [1] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [2] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [3] Dual-Energy CT in the Assessment of Mediastinal Lymph Nodes: Comparative Study of Virtual Non-Contrast and True Non-Contrast Images
    Yoo, Seon Young
    Kim, Yookyung
    Cho, Hyun Hae
    Choi, Mi Joo
    Shim, Sung Shine
    Lee, Jeong Kyong
    Baek, Seung Yon
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (03) : 532 - 539
  • [4] Feasibility study of using virtual non-contrast images derived from dual-energy CT to replace true non-contrast images in patients diagnosed with papillary thyroid carcinoma
    Zhou, Jiang
    Zhou, Yan
    Hu, Hao
    Shen, Mei-Ping
    Ge, Ying-Qian
    Tao, Xin-Wei
    Xu, Xiao-Quan
    Su, Guo-Yi
    Wu, Fei-Yun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2021, 29 (04) : 711 - 720
  • [5] Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images
    Lee, Min Hee
    Park, Hee Jin
    Kim, Ji Na
    Kim, Myung Sub
    Hong, Seok Woo
    Park, Jai Hyung
    Kang, Chang Ho
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1138):
  • [6] Can virtual non-contrast imaging replace true non-contrast imaging in multiphase scanning of the neck region?
    Al-Difaie, Zaid
    Scheepers, Max H. M. C.
    Bouvy, Nicole D.
    Engelen, Sanne
    Havekes, Bas
    Postma, Alida A.
    ACTA RADIOLOGICA OPEN, 2023, 12 (09)
  • [7] Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study
    Herpe, Guillaume
    Platon, Alexandra
    Poletti, Pierre-Alexandre
    Lovblad, Karl O.
    Machi, Paolo
    Becker, Minerva
    Muster, Michel
    Perneger, Thomas
    Guillevin, Remy
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (13)
  • [8] Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions
    Matthias Lazar
    Helmut Ringl
    Pascal Baltzer
    Daniel Toth
    Christian Seitz
    Bernhard Krauss
    Ewald Unger
    Stephan Polanec
    Dietmar Tamandl
    Christian J. Herold
    Michael Toepker
    European Radiology, 2020, 30 : 4295 - 4305
  • [9] Dual-layer spectral computed tomography: Virtual non-contrast in comparison to true non-contrast images
    Sauter, Andreas P.
    Muenzel, Daniela
    Dangelmaier, Julia
    Braren, Rickmer
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Noel, Peter B.
    Fingerle, Alexander A.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 104 : 108 - 114
  • [10] Protocol analysis of dual-energy CT for optimization of kidney stone detection in virtual non-contrast reconstructions
    Lazar, Matthias
    Ringl, Helmut
    Baltzer, Pascal
    Toth, Daniel
    Seitz, Christian
    Krauss, Bernhard
    Unger, Ewald
    Polanec, Stephan
    Tamandl, Dietmar
    Herold, Christian J.
    Toepker, Michael
    EUROPEAN RADIOLOGY, 2020, 30 (08) : 4295 - 4305