Dual-Energy CT in Acute Stroke: Could Non-Contrast CT Be Replaced by Virtual Non-Contrast CT? A Feasibility Study

被引:0
|
作者
Herpe, Guillaume [1 ,2 ]
Platon, Alexandra [1 ]
Poletti, Pierre-Alexandre [3 ]
Lovblad, Karl O. [4 ]
Machi, Paolo [4 ]
Becker, Minerva [3 ]
Muster, Michel [4 ]
Perneger, Thomas [5 ]
Guillevin, Remy [2 ]
机构
[1] Univ Hosp Geneva, Div Radiol, Emergency Radiol Unit, 4 Rue Gabrielle Perret Gentil, CH-1205 Geneva, Switzerland
[2] Poitiers Univ, DACTIM MIS Lab, I3M, F-86021 Poitiers, France
[3] Univ Hosp Geneva, Div Radiol, 4 Rue Gabrielle Perret Gentil, CH-1205 Geneva, Switzerland
[4] Univ Hosp Geneva, Div Neuroradiol, 4 Rue Gabrielle Perret Gentil, CH-1205 Geneva, Switzerland
[5] Univ Hosp Geneva, Div Clin Epidemiol, 4 Rue Gabrielle Perret Gentil, CH-1205 Geneva, Switzerland
关键词
dual-energy CT; acute ischemic stroke; virtual non-contrast CT; ANGIOGRAPHY SOURCE IMAGES; ACUTE ISCHEMIC-STROKE; COMPUTED-TOMOGRAPHY; NONCONTRAST CT; SCORE;
D O I
10.3390/jcm13133647
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We aimed to evaluate whether virtual non-contrast cerebral computed tomography (VNCCT) reconstructed from intravenous contrast-enhanced dual-energy CT (iv-DECT) could replace non-contrast CT (NCCT) in patients with suspected acute cerebral ischemia. Method: This retrospective study included all consecutive patients in whom NCCT followed by iv-DECT were performed for suspected acute ischemia in our emergency department over a 1-month period. The Alberta Stroke Program Early CT Score (ASPECTS) was used to determine signs of acute ischemia in the anterior and posterior circulation, the presence of hemorrhage, and alternative findings, which were randomly evaluated via the consensus reading of NCCT and VNCCT by two readers blinded to the final diagnosis. An intraclass correlation between VNCCT and NCCT was calculated for the ASPECTS values. Both techniques were evaluated for their ability to detect ischemic lesions (ASPECTS <10) when compared with the final discharge diagnosis (reference standard). Results: Overall, 148 patients (80 men, mean age 64 years) were included, of whom 46 (30%) presented with acute ischemia, 6 (4%) presented with intracerebral hemorrhage, 11 (7%) had an alternative diagnosis, and 85 (59%) had no pathological findings. The intraclass correlation coefficients of the two modalities were 0.97 (0.96-0.98) for the anterior circulation and 0.77 (0.69-0.83) for the posterior circulation. The VNCCT's sensitivity for detecting acute ischemia was higher (41%, 19/46) than that of NCCT (33%, 15/46). Specificity was similar between the two techniques, at 94% (97/103) and 98% (101/103), respectively. Conclusions: Our results show that VNCCT achieved a similar diagnostic performance as NCCT and could, thus, replace NCCT in assessing patients with suspected acute cerebral ischemia.
引用
下载
收藏
页数:12
相关论文
共 50 条
  • [1] Dual-Energy CT in the Assessment of Mediastinal Lymph Nodes: Comparative Study of Virtual Non-Contrast and True Non-Contrast Images
    Yoo, Seon Young
    Kim, Yookyung
    Cho, Hyun Hae
    Choi, Mi Joo
    Shim, Sung Shine
    Lee, Jeong Kyong
    Baek, Seung Yon
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (03) : 532 - 539
  • [2] Virtual Non-Contrast CT Using Dual-Energy Spectral CT: Feasibility of Coronary Artery Calcium Scoring
    Song, Inyoung
    Yi, Jeong Geun
    Park, Jeong Hee
    Kim, Sung Mok
    Lee, Kyung Soo
    Chung, Myung Jin
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (03) : 321 - 329
  • [3] Virtual Non-Contrast Dual-Energy CT for Proton Therapy Dose Calculation
    Lalonde, A.
    Xie, Y.
    Burgdorf, B.
    O'Reilly, S.
    Ingram, W.
    Yin, L.
    Zou, J.
    Dong, L.
    Bouchard, H.
    Teo, B.
    MEDICAL PHYSICS, 2019, 46 (06) : E127 - E128
  • [4] Detection of fatty liver using virtual non-contrast dual-energy CT
    Zhang, Pengcheng Peter
    Choi, Hailey H.
    Ohliger, Michael A.
    ABDOMINAL RADIOLOGY, 2022, 47 (06) : 2046 - 2056
  • [5] Detection of fatty liver using virtual non-contrast dual-energy CT
    Pengcheng Peter Zhang
    Hailey H. Choi
    Michael A. Ohliger
    Abdominal Radiology, 2022, 47 : 2046 - 2056
  • [6] Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images
    Lee, Min Hee
    Park, Hee Jin
    Kim, Ji Na
    Kim, Myung Sub
    Hong, Seok Woo
    Park, Jai Hyung
    Kang, Chang Ho
    BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1138):
  • [7] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694
  • [8] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Hongwei Liang
    Silin Du
    Gaowu Yan
    Yang Zhou
    Tianyu Yang
    Zhiwei Zhang
    Chenyi Luo
    Hongfan Liao
    Yongmei Li
    Abdominal Radiology, 2023, 48 : 2596 - 2603
  • [9] Dual-energy CT of the pancreas: comparison between virtual non-contrast images and true non-contrast images in the detection of pancreatic lesion
    Liang, Hongwei
    Du, Silin
    Yan, Gaowu
    Zhou, Yang
    Yang, Tianyu
    Zhang, Zhiwei
    Luo, Chenyi
    Liao, Hongfan
    Li, Yongmei
    ABDOMINAL RADIOLOGY, 2023, 48 (08) : 2596 - 2603
  • [10] Quantitative Accuracy of Virtual Non-Contrast Imaging in Various Dual-Energy CT Scanners
    Ahmad, M.
    Jacobsen, M.
    Cody, D.
    Surabhi, V.
    MEDICAL PHYSICS, 2018, 45 (06) : E154 - E154