Analysis and optimization of injection characteristics and comprehensive performance of low GWP refrigerant HP-1 in high temperature heat pump systems

被引:3
|
作者
Wang, Yuehan [1 ]
Nan, Xiaohong [1 ]
Ouyang, Hongsheng [2 ]
Guo, Zhikai [2 ]
Hu, Bin [3 ]
Wang, R. Z.
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Zhejiang Res Inst Chem Ind Co Ltd, State Key Lab Fluorinated Greenhouse Gases Replace, Hangzhou 310023, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
HP-1; HTHP; Environmentally friendly refrigerant; Injection Characteristics; Performance analysis optimization; Decarbonization; VAPOR-INJECTION; SCROLL COMPRESSOR; 2-PHASE INJECTION; LIQUID INJECTION; R32; HCFO-1224YD(Z); INTERMEDIATE; ALTERNATIVES; R1233ZD(E); HFC-245FA;
D O I
10.1016/j.enbuild.2023.113799
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the context of low-GWP refrigerants becoming a research hotspot, the environmentally friendly refrigerant HP1 with independent intellectual property rights in China has demonstrated significant advantages in fields such as data centers and 5G base stations. However, there are few applied studies in the field of high-temperature heat pumps (HTHPs), therefore, in this study, HP-1 was utilized in HTHP system and this process was combined with the injection technology. It has been proven to be an effective approach for performance improvement. The injection characteristics of HP-1-based HTHP were analyzed and optimized with a focus on safety, stability, and efficient operation. The application advantages of HP-1 were compared and analyzed in terms of thermodynamic performance and Total Equivalent Warming Impact. The results indicated that there were three types of characteristic injection pressures based on system performance, corresponding to the maximum coefficient of performance (COP), the lowest electronic expansion valve inlet refrigerant temperature, and the lowest exhaust temperature of the compressor. Further, the corresponding control equations for injection pressure were obtained. Based on the safety injection pressure, the optimal COP under injection pressure could effectively improve the COP of the system by 2.1-5.2 %, and the exhaust temperature also increased by 6.1-10.1 %. When the temperature of the heat source was 50 degrees C and the target heating temperature was 120 degrees C, the heating capacity of HP-1 increased by 10.8 % compared with that of R245fa, the COP of the system increased by 2.7 %, and the volume heating capacity increased by 10.3 %. Moreover, the emission reduction effect of HP-1 was significant, and the carbon dioxide emissions were reduced by 15.4-39.1 %. The analysis shows that HP-1 exhibits better performance and environmental characteristics than HFC-245fa. This study is of guiding significance to improve the thermodynamic performance of HTHP, for the safe and efficient operation and energy saving and emission reduction in the industrial field.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Matching Characteristics of Expansion Valve Opening and Flow Rate of High Temperature Heat Pump with Green Refrigerant HP-1
    Wang Y.
    Nan X.
    Ouyang H.
    Guo Z.
    Hu B.
    Wang R.
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2023, 57 (10): : 1367 - 1377
  • [2] PERFORMANCE OF LOW GWP FLUIDS IN HEAT PUMP SYSTEMS
    Radulovic, Jovana
    JOURNAL OF THERMAL ENGINEERING, 2016, 2 (03): : 748 - 753
  • [3] Heating performance of recuperative heat pump using low-GWP mixed refrigerant
    Luo J.
    Yang K.
    Zhao Z.
    Wang Q.
    Chen G.
    Huagong Xuebao/CIESC Journal, 2021, 72 : 84 - 90
  • [4] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 1193 - 1202
  • [5] Analysis of optimal intermediate temperature and injection pressure for refrigerant injection heat pump systems with economiser
    Xu, Qiangqiang
    Wu, Jianghong
    Guo, Zhengdao
    Xue, Xiangjin
    Li, Xiaoyan
    APPLIED THERMAL ENGINEERING, 2022, 210
  • [6] COMPARISON ON LOW GWP REFRIGERANTS FOR HIGH TEMPERATURE HEAT PUMP
    Hu, Bin
    Yan, Yuanbo
    Wang, R. Z.
    5TH IIR INTERNATIONAL CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR), 2017, : 538 - 547
  • [7] Performance of the very high-temperature heat pump with low GWP working fluids
    Mikielewicz, Dariusz
    Wajs, Jan
    ENERGY, 2019, 182 : 460 - 470
  • [8] EXERGY AND EXERGOENVIRONMENTAL ASSESSMENT AND OPTIMIZATION OF LOW GWP REFRIGERANT FOR VAPOR COMPRESSION HEAT PUMP SYSTEM
    Aisyah, Nyayu
    Alhamid, Muhamad Idrus
    Nasruddin
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2018, 9 (06) : 1256 - 1265
  • [9] THEORETICAL STUDY OF LOW GWP REFRIGERANTS IN HIGH-TEMPERATURE HEAT PUMP SYSTEMS
    Zhang, Fan
    Meng, Zhaofeng
    Dong, Suiju
    Liu, Yin
    Ding, Chuangchuang
    Hu, Ziheng
    Wang, Mingming
    3RD IIR CONFERENCE ON HFO REFRIGERANTS AND LOW GWP BLENDS, 2023, : 157 - 163
  • [10] Theoretical performance assessment of low-GWP refrigerant R1233zd(E) applied in high temperature heat pump system
    Jiang, Jiatong
    Hu, Bin
    Wang, R. Z.
    Liu, Hua
    Zhang, Zhiping
    Li, Hongbo
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 897 - 908