Efficacy and safety of zero-fluoroscopy ablation of ventricular arrhythmias originating from the right ventricular outflow tract: Comparison with fluoroscopy-guided ablation without a three-dimensional electroanatomic mapping system

被引:2
|
作者
Vu, Ba Van [1 ,2 ]
Phan, Phong Dinh [3 ]
Pham, Linh Tran [4 ]
Hoang, Kien Trung [2 ]
Do, Thinh Duc [2 ]
Nguyen, Hung Manh [2 ]
Ngo, Linh Thi Hai [5 ]
Le, Dung Tien [2 ]
Phan, Nguyen Thao [2 ,6 ]
Nguyen, Huu Cong [2 ,6 ]
Luong, Thuc Cong [1 ,7 ,8 ]
机构
[1] Vietnam Mil Med Univ, Cardiol Dept, Hanoi, Vietnam
[2] E Hosp, Cardiovasc Ctr, Hanoi, Vietnam
[3] Hanoi Med Univ, Cardiol Dept, Hanoi, Vietnam
[4] Bach Mai Hosp, Vietnam Natl Heart Inst, Hanoi, Vietnam
[5] Univ Queensland, Sch Clin Med, Herston, Qld, Australia
[6] Hanoi Natl Univ, Univ Med & Pharm, Hanoi, Vietnam
[7] Mil Hosp 103, Cardiol Dept, Hanoi, Vietnam
[8] Vietnam Mil Med Univ, Mil Hosp 103, Cardiol Dept, Hanoi, Vietnam
关键词
right ventricular outflow tract; ventricular arrhythmias; zero-fluoroscopy ablation; CATHETER ABLATION; TACHYCARDIA;
D O I
10.1002/joa3.12815
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRadiofrequency catheter ablation is the preferred treatment choice for ventricular arrhythmias (VAs) originating from right ventricular outflow tract (RVOT) in symptomatic patients and is usually performed under fluoroscopy guidance. Zero-fluoroscopy (ZF) ablations using 3D mapping system applied for treatment of various types of arrhythmias are trending and practiced in many centers around the world, but rarely done in Vietnam. The objective of this study was to evaluate the efficacy and safety of zero-fluoroscopy ablation of RVOT VAs, compared with fluoroscopy-guided ablation without a 3D electroanatomic mapping (EAM) system. Methods and ResultsWe conducted a nonrandomized, prospective single-center study including 114 patients with RVOT VAs that had electrocardiographic features of typical left bundle branch block, inferior axis QRS morphology, and a precordial transition >= V-3, from May 2020 to July 2022. The patients were assigned (without randomization) to two different approaches of either zero-fluoroscopy ablation under the guidance of the Ensite system (ZF group) or fluoroscopy-guided ablation without a 3D EAM (fluoroscopy group) in a 1:1 ratio. After a follow-up time of 5.0 +/- 4.9 months and 6.9 +/- 9.3 months in the ZF and fluoroscopy groups, respectively, the results showed a higher success rate in the fluoroscopy group than in the complete ZF group (87.3% vs 86.8%), although the difference was not statistically significant. No major complication was noted in both the groups. ConclusionZF ablation for RVOT VAs can be done safely and effectively using the 3D electroanatomic mapping system. The results of ZF approach are comparable to that of the fluoroscopy-guided approach without a 3D EAM system.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 49 条
  • [41] Role of right ventricular three-dimensional electroanatomic voltage mapping for arrhythmic risk stratification of patients with corrected tetralogy of Fallot or other congenital heart disease involving the right ventricular outflow tract
    Drago, Fabrizio
    Pazzano, Vincenzo
    Di Mambro, Corrado
    Russo, Mario Salvatore
    Palmieri, Rosalinda
    Silvetti, Massimo Stefano
    Giannico, Salvatore
    Leonardi, Benedetta
    Amodeo, Antonio
    Di Ciommo, Vincenzo Maria
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 422 - 429
  • [42] Katheterablation von ventrikulären Ausflusstrakt-Arrhythmien unter Einsatz eines elektroanatomischen Mapping-SystemsCatheter Ablation of Ventricular Outflow Tract Arrhythmias Using an Electroanatomic Mapping System
    Marc Horlitz
    Philipp Schley
    Armin Sause
    Michael Müller
    Dong-In Shin
    Rolf Michael Klein
    Hartmut Gülker
    Medizinische Klinik, 2005, 100 : 611 - 616
  • [43] Idiopathic right ventricular arrhythmias requiring additional ablation from the left-sided outflow tract: ECG characteristics and efficacy of an anatomical approach
    Hisazaki, Kaori
    Hasegawa, Kanae
    Kaseno, Kenichi
    Miyazaki, Shinsuke
    Aoyama, Daisetsu
    Mukai, Moe
    Nodera, Minoru
    Shiomi, Yuichiro
    Tama, Naoto
    Ikeda, Hiroyuki
    Ishida, Kentaro
    Uzui, Hiroyasu
    Tada, Hiroshi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (10) : 2653 - 2664
  • [44] Clinical Characteristics of Arrhythmogenic Right Ventricular Cardiomyopathy and the Radiofrequency Catheter Ablation under the Guidance of Three-Dimensional Mapping System
    Hong, L.
    Wang, H.
    Chen, Z. Q.
    Lai, H. L.
    Yin, Q. L.
    Lu, L. X.
    CARDIOLOGY, 2010, 117 : 73 - 73
  • [45] Clinical Characteristics of Arrhythmogenic Right Ventricular Cardiomyopathy and the Radiofrequency Catheter Ablation under the Guidance of Three-Dimensional Mapping System
    Wang Hong
    Hong Lang
    Chen Zhang-Qiang
    Lai Heng-Li
    Lu Lin-Xiang
    CIRCULATION, 2010, 122 (02) : E306 - E306
  • [46] Is it possible to create a linear lesion with no local electrograms? Comparison between a three-dimensional mapping system and conventional fluoroscopy for cavotricuspid isthmus ablation of typical atrial flutter
    Muto, Carmine
    Canciello, Michelangelo
    Carreras, Giovanni
    Ottaviano, Luca
    Ascione, Luigi
    Angelini, Salvatore
    Tuccillo, Bernardino
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2007, 8 (06) : 414 - 418
  • [47] Image integration into 3-dimensional-electro-anatomical mapping system facilitates safe ablation of ventricular arrhythmias originating from the aortic root and its vicinity
    Jularic, Mario
    Akbulak, Ruken Oezge
    Schaeffer, Benjamin
    Moser, Julia
    Nuehrich, Jana
    Meyer, Christian
    Eickholt, Christian
    Willems, Stephan
    Hoffmann, Boris A.
    EUROPACE, 2018, 20 (03): : 520 - 527
  • [48] Microwave ablation of an ischemic sustained ventricular tachycardia during aortocoronary bypass, mitral valve and tricuspid valve surgery guided by a three-dimensional nonfluoroscopic mapping system (CARTO)
    Braun, MU
    Knaut, M
    Rauwolf, T
    Strasser, RH
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 13 (03) : 243 - 247
  • [49] Microwave Ablation of an Ischemic Sustained Ventricular Tachycardia During Aortocoronary Bypass, Mitral Valve and Tricuspid Valve Surgery Guided by a Three-Dimensional Nonfluoroscopic Mapping System (CARTO)
    M. U. Braun
    M. Knaut
    T. Rauwolf
    R. H. Strasser
    Journal of Interventional Cardiac Electrophysiology, 2005, 13 : 243 - 247