Efficacy and safety of zero-fluoroscopy ablation of ventricular arrhythmias originating from the right ventricular outflow tract: Comparison with fluoroscopy-guided ablation without a three-dimensional electroanatomic mapping system

被引:2
|
作者
Vu, Ba Van [1 ,2 ]
Phan, Phong Dinh [3 ]
Pham, Linh Tran [4 ]
Hoang, Kien Trung [2 ]
Do, Thinh Duc [2 ]
Nguyen, Hung Manh [2 ]
Ngo, Linh Thi Hai [5 ]
Le, Dung Tien [2 ]
Phan, Nguyen Thao [2 ,6 ]
Nguyen, Huu Cong [2 ,6 ]
Luong, Thuc Cong [1 ,7 ,8 ]
机构
[1] Vietnam Mil Med Univ, Cardiol Dept, Hanoi, Vietnam
[2] E Hosp, Cardiovasc Ctr, Hanoi, Vietnam
[3] Hanoi Med Univ, Cardiol Dept, Hanoi, Vietnam
[4] Bach Mai Hosp, Vietnam Natl Heart Inst, Hanoi, Vietnam
[5] Univ Queensland, Sch Clin Med, Herston, Qld, Australia
[6] Hanoi Natl Univ, Univ Med & Pharm, Hanoi, Vietnam
[7] Mil Hosp 103, Cardiol Dept, Hanoi, Vietnam
[8] Vietnam Mil Med Univ, Mil Hosp 103, Cardiol Dept, Hanoi, Vietnam
关键词
right ventricular outflow tract; ventricular arrhythmias; zero-fluoroscopy ablation; CATHETER ABLATION; TACHYCARDIA;
D O I
10.1002/joa3.12815
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundRadiofrequency catheter ablation is the preferred treatment choice for ventricular arrhythmias (VAs) originating from right ventricular outflow tract (RVOT) in symptomatic patients and is usually performed under fluoroscopy guidance. Zero-fluoroscopy (ZF) ablations using 3D mapping system applied for treatment of various types of arrhythmias are trending and practiced in many centers around the world, but rarely done in Vietnam. The objective of this study was to evaluate the efficacy and safety of zero-fluoroscopy ablation of RVOT VAs, compared with fluoroscopy-guided ablation without a 3D electroanatomic mapping (EAM) system. Methods and ResultsWe conducted a nonrandomized, prospective single-center study including 114 patients with RVOT VAs that had electrocardiographic features of typical left bundle branch block, inferior axis QRS morphology, and a precordial transition >= V-3, from May 2020 to July 2022. The patients were assigned (without randomization) to two different approaches of either zero-fluoroscopy ablation under the guidance of the Ensite system (ZF group) or fluoroscopy-guided ablation without a 3D EAM (fluoroscopy group) in a 1:1 ratio. After a follow-up time of 5.0 +/- 4.9 months and 6.9 +/- 9.3 months in the ZF and fluoroscopy groups, respectively, the results showed a higher success rate in the fluoroscopy group than in the complete ZF group (87.3% vs 86.8%), although the difference was not statistically significant. No major complication was noted in both the groups. ConclusionZF ablation for RVOT VAs can be done safely and effectively using the 3D electroanatomic mapping system. The results of ZF approach are comparable to that of the fluoroscopy-guided approach without a 3D EAM system.
引用
收藏
页码:185 / 191
页数:7
相关论文
共 49 条
  • [31] Novel strategy of remote magnetic navigation-guided ablation for ventricular arrhythmias from right ventricle outflow tract
    Xie, Yun
    Liu, Ao
    Jin, Qi
    Zhang, Ning
    Jia, Kangni
    Lin, Changjian
    Ling, Tianyou
    Chen, Kang
    Pan, Wenqi
    Wu, Liqun
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [32] Echocardiographic Evaluation in Patients With Idiopathic Ventricular Arrhythmias Originating From Right Ventricular Outflow Tract Before and One Year After Radiofrequency Catheter Ablation
    Ardashev, A. V.
    Sklyarova, T. F.
    Shavarov, A. A.
    Mangutov, D. A.
    Zhelyakov, E. G.
    Pestovskaya, O. R.
    Savina, L. N.
    Sharonova, S. P.
    KARDIOLOGIYA, 2009, 49 (03) : 38 - 42
  • [33] Safety and efficacy of coronary angiographic image integration tool-guided ablation of left sided outflow tract ventricular arrhythmias
    Yalin, Kivanc
    Soysal, Ali Ugur
    Aksu, Tolga
    Onder, Sukriye Ebru
    Ozturk, Sila
    Yalman, Hakan
    Mutlu, Deniz
    Ercan, Osman Talha
    Ikitimur, Baris
    Cimci, Murat
    Durmaz, Eser
    Karadag, Bilgehan
    Bilge, Ahmet Kaya
    Huang, Henry
    Karpuz, Hakan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (01) : 31 - 34
  • [34] Safety and efficacy of coronary angiographic image integration tool-guided ablation of left sided outflow tract ventricular arrhythmias
    Kivanc Yalin
    Ali Ugur Soysal
    Tolga Aksu
    Sukriye Ebru Onder
    Sila Ozturk
    Hakan Yalman
    Deniz Mutlu
    Osman Talha Ercan
    Baris Ikitimur
    Murat Cimci
    Eser Durmaz
    Bilgehan Karadag
    Ahmet Kaya Bilge
    Henry Huang
    Hakan Karpuz
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 31 - 34
  • [35] Endomyocardial biopsy to validate three-dimensional electroanatomic voltage mapping as a new diagnostic tool to differentiate right ventricular outflow tract tachycardia from arrhythmogenic right ventricular cardiomyopathy
    Basso, C
    Corrado, D
    Tokajuk, B
    Leoni, L
    Pavei, A
    Buja, G
    Iliceto, S
    Thiene, G
    MODERN PATHOLOGY, 2006, 19 : 46A - 46A
  • [36] PREMATURE VENTRICULAR CONTRACTIONS ORIGINATING FROM THE RIGHT VENTRICULAR OUTFLOW TRACT: THREE-DIMENSIONAL DISTRIBUTION OF THE TARGET SITES AND THEIR ELECTROCARDIOGRAPHIC CHARACTERISTICS
    Yu, Jian
    Yang, Bing
    Chen, Ming-Long
    Chen, Hong-Wu
    Ju, Wei-Zhu
    Shan, Qi-Jun
    Zou, Jian-Gang
    Chen, Chun
    Xu, Dong-Jie
    Hou, Xiao-Feng
    Cao, Ke-Jiang
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2009, 36 (08): : 834 - 838
  • [37] Endomyocardial biopsy to validate three-dimensional electroanatomic voltage mapping as a new diagnostic tool to differentiate right ventricular outflow tract tachycardia from arrhythmogenic right ventricular cardiomyopathy
    Basso, C
    Corrado, D
    Tokajuk, B
    Leoni, L
    Pavei, A
    Buja, G
    Iliceto, S
    Thiene, G
    LABORATORY INVESTIGATION, 2006, 86 : 46A - 46A
  • [38] Three-Dimensional Electroanatomical Mapping-Guided Catheter Ablation of Ventricular Tachycardia Originating in the Left Anterior Papillary Muscle
    Irie, Tadanobu
    Kaneko, Yoshiaki
    Nakahara, Takehiro
    Kurabayashi, Masahiko
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (02) : 214 - 215
  • [39] A case of catheter ablation of accessory atrioventricular connection between the right atrial appendage and right ventricle guided by a three-dimensional electroanatomic mapping system
    Goya, M
    Takahashi, A
    Nakagawa, H
    Iesaka, Y
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1999, 10 (08) : 1112 - 1118
  • [40] Long-term outcomes of non-contact multi-electrode balloon catheter mapping-guided ablation of ventricular arrhythmias originating from the outflow tract
    Almeida, Ines
    Lousinha, Ana
    Cunha, Pedro Silva
    Valente, Bruno
    Paulo, Margarida
    Delgado, Ana Sofia
    Ferreira, Rui
    Oliveira, Mario
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2022, 41 (06) : 487 - 493