Accuracy of autonomous robotic surgery for dental implant placement in fully edentulous patients: A retrospective case series study

被引:21
|
作者
Li, Ping [1 ,2 ,3 ]
Chen, Jiahao [1 ,4 ]
Li, An [5 ]
Luo, Ke [1 ]
Xu, Shulan [1 ]
Yang, Shuo [1 ]
机构
[1] Southern Med Univ, Stomatol Hosp, Ctr Oral Implantol, Sch Stomatol, Guangzhou, Peoples R China
[2] Guangzhou Med Univ, Dept Prosthodont, Sch & Hosp Stomatol, Guangzhou, Guangdong, Peoples R China
[3] Guangzhou Med Univ, Sch & Hosp Stomatol, Guangdong Engn Res Ctr Oral Restorat & Reconstruct, Guangzhou, Guangdong, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Guangzhou, Peoples R China
[5] Southern Med Univ, Stomatol Hosp, Sch Stomatol, Dept Periodontol, Guangzhou, Peoples R China
关键词
accuracy; computer-assisted implant dentistry; dental implants; fully edentulous; robot-assisted surgery; DYNAMIC NAVIGATION;
D O I
10.1111/clr.14188
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the accuracy of dental implant placement using the robotic computer-assisted implant surgery (r-CAIS) technology in fully edentulous patients.Materials and Methods: Fully edentulous and terminal dentition patients were enrolled for r-CAIS technology. Based on the cone-beam computed tomography (CBCT) examination, a customized positioning marker and a preoperative surgical plan were created before surgery. During the implant surgery, the implant osteotomy and placement were automatically performed using an autonomous robotic surgery system under the surgeon's supervision. A postoperative CBCT scan was used to determine the discrepancies between the planned and placed implants.Results: Ten patients with 59 implants underwent autonomous robotic surgery. No adverse surgical events occurred. The deviations of global coronal, global apical, and angular were 0.67 +/- 0.37 mm (95% CI: 0.58-0.77 mm), 0.69 +/- 0.37 mm (95% CI: 0.59-0.78 mm), and 1.27 degrees +/- 0.59 degrees (95% CI: 1.42 degrees-1.11 degrees), respectively.Conclusions: The autonomous r-CAIS technology proved an accurate surgical approach for implant placement in fully edentulous patients due to the control of the angular deviation. Autonomous robotic surgery seems promising as an accurate technology for treating fully edentulous patients. However, further trials are required to provide more hard clinical evidence.
引用
收藏
页码:1428 / 1437
页数:10
相关论文
共 50 条
  • [31] Autonomous Dental Implant Robotic System Utilization for Implant Placement and Transcrestal Sinus Elevation Using Osseodensification: A Case Report
    Sun, Mingxu
    Yue, Chongxia
    Stuhr, Sandra
    Fu, Xiaojie
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2024, 44 (06) : 697 - 707
  • [32] Clinical Accuracy of Flapless Computer-Guided Surgery for Implant Placement in Edentulous Arches
    Vieira, Dalton Marinho
    Sotto-Maior, Bruno Salles
    Villaca de Souza Barros, Carlos Alberto
    Reis, Elson Simoes
    Francischone, Carlos Eduardo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1347 - 1351
  • [33] Implant survival and patient satisfaction in completely edentulous patients with immediate placement of implants: a retrospective study
    Kim, Hye-Sung
    Cho, Han-A
    Kim, Young Youn
    Shin, Hosung
    BMC ORAL HEALTH, 2018, 18
  • [34] Implant survival and patient satisfaction in completely edentulous patients with immediate placement of implants: a retrospective study
    Hye-sung Kim
    Han-A Cho
    Young youn Kim
    Hosung Shin
    BMC Oral Health, 18
  • [35] Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Zhuang, Minjie
    Chen, Xiaojun
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF DENTISTRY, 2022, 123
  • [36] Accuracy of Edentulous Computer-Aided Implant Surgery as Compared to Virtual Planning: A Retrospective Multicenter Study
    Vinci, R.
    Manacorda, M.
    Abundo, R.
    Lucchina, A. G.
    Scarano, A.
    Crocetta, C.
    Lo Muzio, L.
    Gherlone, E. F.
    Mastrangelo, F.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (03)
  • [37] Evaluation of accuracy and membrane perforation in robotic-assisted implant surgery for transalveolar sinus floor elevation: a retrospective case series
    Yang, Tao
    Yi, Wenjing
    Xu, Wenan
    Xing, Xiaojian
    Wu, Buling
    BMC ORAL HEALTH, 2025, 25 (01):
  • [38] The accuracy of a novel image-guided hybrid robotic system for dental implant placement: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Lan, Kengliang
    Zhuang, Minjie
    Wang, Shigang
    Wang, Feng
    Chen, Xiaojun
    Wu, Yiqun
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2023, 19 (01):
  • [39] Accuracy of Computer-Guided Flapless Implant Surgery in Fully Edentulous Arches and in Edentulous Arches With Fresh Extraction Sockets
    Albiero, Alberto M.
    Quartuccio, Luca
    Benato, Andrea
    Benato, Renato
    IMPLANT DENTISTRY, 2019, 28 (03) : 256 - 264
  • [40] In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer-assisted implant surgery
    He, Jin
    Zhang, Qinmeng
    Wang, Xueting
    Fu, Mengdie
    Zhang, Hui
    Song, Luyao
    Pu, Rui
    Jiang, Zhiwei
    Yang, Guoli
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (02) : 385 - 401