Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques

被引:4
|
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
Ueta, Hiroshi [2 ]
Takata, Tadanori [2 ]
Mitsui, Wataru [2 ]
Nagata, Hiroji [3 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa 9200942, Japan
[2] Kanazawa Univ Hosp, Radiol Div, 13-1 Takara Machi, Kanazawa 9208641, Japan
[3] Kanazawa Med Univ Hosp, Dept Med Technol, Sect Radiol Technol, Daigaku 1-1,Uchinada, Kahoku 9200293, Japan
关键词
Tomography; X-ray computed; Comparative study; Iodine; Radiation dosage; LOW-CONTRAST DETECTABILITY; RADIATION-DOSE REDUCTION; ABDOMINAL CT; IODINE QUANTIFICATION; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; MULTIDETECTOR CT; SPECTRAL CT; QUALITY;
D O I
10.1007/s00330-023-09491-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate the performance of virtual monochromatic (VM) images with the same dose and iodine contrast as those for single-energy (SE) images using five dual-energy (DE) scanners with DE techniques: two generations of fast kV switching (FKS), two generations of dual source (DS), and one split filter (SF). Methods A water-bath phantom with a diameter of 300 mm, which contains one rod-shaped phantom made of a material equivalent to soft-tissue and two rod-shaped phantoms made of diluted iodine (2 and 12 mg/mL), was scanned using both SE (120, 100, and 80 kV) and DE techniques with the same CT dose index in each scanner. The VM energy at which the CT number of the iodine rod is closest to that of each SE tube voltage was determined as the equivalent energy (Eeq). A detectability index (d ') was calculated from the noise power spectrum, the task transfer functions, and a task function corresponding to each rod. The percentage of the d ' value of the VM image to that of the corresponding SE image was calculated for performance comparison. Results The average percentages of d ' of FKS1, FKS2, DS1, DS2, and SF were 84.6%, 96.2%, 94.3%, 107%, and 104% for 120 kV-Eeq; 75.9%, 91.2%, 88.2%, 99.2%, and 82.6% for 100 kV-Eeq; 71.6%, 88.9%, 82.6%, 85.2%, and 62.3% for 80 kV-Eeq, respectively. Conclusion The performance of VM images was on the whole inferior to that of SE images especially at low equivalent energy levels, depending on the DE techniques and their generations.
引用
收藏
页码:5752 / 5760
页数:9
相关论文
共 50 条
  • [41] Detectability of Urinary Stones on Virtual Nonenhanced Images Generated at Pyelographic-Phase Dual-Energy CT
    Takahashi, Naoki
    Vrtiska, Terri J.
    Kawashima, Akira
    Hartman, Robert P.
    Primak, Andrew N.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    RADIOLOGY, 2010, 256 (01) : 184 - 190
  • [42] Pseudo dual-energy CT-derived iodine mapping using single-energy CT data based on a convolution neural network
    Yuasa, Yuki
    Shiinoki, Takehiro
    Fujimoto, Koya
    Tanaka, Hidekazu
    BJR OPEN, 2023, 5 (01):
  • [43] Estimating dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network ?
    Lyu, Tianling
    Zhao, Wei
    Zhu, Yinsu
    Wu, Zhan
    Zhang, Yikun
    Chen, Yang
    Luo, Limin
    Li, Shuo
    Xing, Lei
    MEDICAL IMAGE ANALYSIS, 2021, 70
  • [44] The Effect of Beam Overlapping in Dual-Energy Volume CT Scans and Single-Energy Helical Scans
    Correa, N.
    Barreto, I.
    Arreola, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E648 - E648
  • [45] Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction
    Jensen, Corey T.
    Wong, Vincenzo K.
    Wagner-Bartak, Nicolaus A.
    Liu, Xinming
    Sobha, Renjith Padmanabhan Nair
    Sun, Jia
    Likhari, Gauruv S.
    Gupta, Shiva
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [46] Deep-learned generation of renal dual-energy CT from a single-energy scan
    Sheikhi, M.
    Sina, S.
    Karimipourfard, M.
    CLINICAL RADIOLOGY, 2024, 79 (01) : e17 - e25
  • [47] Dual-energy CT in differentiating benign sinonasal lesions from malignant ones: comparison with simulated single-energy CT, conventional MRI, and DWI
    Peng Wang
    Zuohua Tang
    Zebin Xiao
    Rujian Hong
    Rong Wang
    Yuzhe Wang
    Yang Zhan
    European Radiology, 2022, 32 : 1095 - 1105
  • [48] Dual-energy CT angiography of abdomen with routine concentration contrast agent in comparison with conventional single-energy CT with high concentration contrast agent
    He, Jingzhen
    Wang, Qing
    Ma, Xiangxing
    Sun, Zhiyuan
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (02) : 221 - 227
  • [49] Evaluation of three-dimensional dual-energy CT cholangiopancreatography image quality in patients with pancreatobiliary dilatation: Comparison with conventional single-energy CT
    Li, Bin
    Ni, Jianming
    Chen, Fangming
    Lu, Fengqi
    Zhang, Lei
    Wu, Wenjuan
    Zhang, Zhuiyang
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 11
  • [50] Attention Augmented Deep Learning-Based Dual-Energy CT Imaging Via Single-Energy CT Data
    Zhang, W.
    Lv, T.
    Chen, Y.
    Sun, B.
    Zhao, W.
    MEDICAL PHYSICS, 2022, 49 (06) : E181 - E181