Virtual monochromatic images of dual-energy CT as an alternative to single-energy CT: performance comparison using a detectability index for different acquisition techniques

被引:4
|
作者
Kawashima, Hiroki [1 ]
Ichikawa, Katsuhiro [1 ]
Ueta, Hiroshi [2 ]
Takata, Tadanori [2 ]
Mitsui, Wataru [2 ]
Nagata, Hiroji [3 ]
机构
[1] Kanazawa Univ, Inst Med Pharmaceut & Hlth Sci, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa 9200942, Japan
[2] Kanazawa Univ Hosp, Radiol Div, 13-1 Takara Machi, Kanazawa 9208641, Japan
[3] Kanazawa Med Univ Hosp, Dept Med Technol, Sect Radiol Technol, Daigaku 1-1,Uchinada, Kahoku 9200293, Japan
关键词
Tomography; X-ray computed; Comparative study; Iodine; Radiation dosage; LOW-CONTRAST DETECTABILITY; RADIATION-DOSE REDUCTION; ABDOMINAL CT; IODINE QUANTIFICATION; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; INITIAL-EXPERIENCE; MULTIDETECTOR CT; SPECTRAL CT; QUALITY;
D O I
10.1007/s00330-023-09491-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To investigate the performance of virtual monochromatic (VM) images with the same dose and iodine contrast as those for single-energy (SE) images using five dual-energy (DE) scanners with DE techniques: two generations of fast kV switching (FKS), two generations of dual source (DS), and one split filter (SF). Methods A water-bath phantom with a diameter of 300 mm, which contains one rod-shaped phantom made of a material equivalent to soft-tissue and two rod-shaped phantoms made of diluted iodine (2 and 12 mg/mL), was scanned using both SE (120, 100, and 80 kV) and DE techniques with the same CT dose index in each scanner. The VM energy at which the CT number of the iodine rod is closest to that of each SE tube voltage was determined as the equivalent energy (Eeq). A detectability index (d ') was calculated from the noise power spectrum, the task transfer functions, and a task function corresponding to each rod. The percentage of the d ' value of the VM image to that of the corresponding SE image was calculated for performance comparison. Results The average percentages of d ' of FKS1, FKS2, DS1, DS2, and SF were 84.6%, 96.2%, 94.3%, 107%, and 104% for 120 kV-Eeq; 75.9%, 91.2%, 88.2%, 99.2%, and 82.6% for 100 kV-Eeq; 71.6%, 88.9%, 82.6%, 85.2%, and 62.3% for 80 kV-Eeq, respectively. Conclusion The performance of VM images was on the whole inferior to that of SE images especially at low equivalent energy levels, depending on the DE techniques and their generations.
引用
收藏
页码:5752 / 5760
页数:9
相关论文
共 50 条
  • [21] CT detection of myocardial blood volume deficits: Dual-energy CT compared with single-energy CT spectra
    Arnoldi, Elisabeth
    Lee, Yeong Shyan
    Ruzsics, Balazs
    Weininger, Markus
    Spears, J. Reid
    Rowley, Christopher P.
    Chiaramida, Salvatore A.
    Costello, Philip
    Reiser, Maximilian F.
    Schoepf, U. Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 421 - 429
  • [22] Dual-energy CT for the detection of skull base invasion in nasopharyngeal carcinoma: comparison of simulated single-energy CT and MRI
    Zhan, Yang
    Wang, Peng
    Wang, Yuzhe
    Wang, Yin
    Tang, Zuohua
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [23] Dual-Energy CT: Techniques in Acquisition and Image Processing
    Pelc, N.
    MEDICAL PHYSICS, 2016, 43 (06) : 3746 - 3746
  • [24] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [25] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [26] Dual-energy CT enterography in evaluation of Crohn's disease: the role of virtual monochromatic images
    Guler, Ezgi
    Unal, Nalan Gulsen
    Hekimsoy, Ilhan
    Kose, Timur
    Harman, Mustafa
    Ozutemiz, Ahmet Omer
    Elmas, Nevra Zehra
    JAPANESE JOURNAL OF RADIOLOGY, 2021, 39 (04) : 341 - 348
  • [27] Dual-energy CT enterography in evaluation of Crohn’s disease: the role of virtual monochromatic images
    Ezgi Guler
    Nalan Gulsen Unal
    Ilhan Hekimsoy
    Timur Kose
    Mustafa Harman
    Ahmet Omer Ozutemiz
    Nevra Zehra Elmas
    Japanese Journal of Radiology, 2021, 39 : 341 - 348
  • [28] Dual-energy CT Imaging Using a Single-energy CT Data via Deep Learning: A Contrast-enhanced CT Study
    Zhao, W.
    Lv, T.
    Chen, Y.
    Xing, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S43 - S43
  • [29] The optimal energy level of virtual monochromatic imaging in dual-energy CT arthrography of the wrist
    Chung, Bo Mi
    Lee, Guen Young
    Kim, Sujin
    BRITISH JOURNAL OF RADIOLOGY, 2024, 98 (1166): : 305 - 311
  • [30] Optimal Virtual Monochromatic Images for Evaluation of Normal Tissues and Head and Neck Cancer Using Dual-Energy CT
    Lam, S.
    Gupta, R.
    Levental, M.
    Yu, E.
    Curtin, H. D.
    Forghani, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (08) : 1518 - 1524