A dual-mode system for water purification and cooling using a thermal desalination technique coupled to a heat pump unit

被引:4
|
作者
Anand, B. [1 ]
Shankar, R. [2 ]
Jimenez-Garcia, J. C. [1 ]
Rivera, W. [1 ]
机构
[1] Univ Nacl Autonoma Mexico, Inst Energias Renovables, Temixco, Morelos, Mexico
[2] MVJ Coll Engn, Dept Aeronaut Engn, Bangalore, India
关键词
Desalination; Cooling; Humidification; -dehumidification; Heat pump; Waste heat recovery; THERMOPHYSICAL PROPERTIES; PERFORMANCE ANALYSIS; EXERGY ANALYSIS; DEHUMIDIFICATION; DRIVEN; ENERGY; OPTIMIZATION; SEAWATER;
D O I
10.1016/j.applthermaleng.2023.120096
中图分类号
O414.1 [热力学];
学科分类号
摘要
Humidification-dehumidification is one of the most suitable small-scale desalination methods based on air humidification and condensation. The major energy-consuming components for a humidification-dehumidification process are a heat source for the humidifier and a cooling source for the dehumidifier. To improve the performance of these processes, the fluids were preheated using different energy sources or waste heat. In recent years, preheating air or saline water using heat from a heat pump's condenser has been explored to improve the system's performance and to produce cooling and desalination simultaneously. However, separate heat exchangers and additional solar collectors/heaters were used to preheat the second fluid. In this work, the air-cooled condenser of a heat pump has been replaced by an evaporative condenser and used as a humidifier. This configuration has been scarcely explored in the literature and requires a single heat exchanger to preheat the fluids. On the other hand, the heat pump's evaporator was used to produce low-temperature coolant, circulated through a cooling coil where the humid air from the evaporative condenser is cooled and dehumidified to produce fresh water and cooling simultaneously. This modification ensures reduced space requirement and better system performance than other heat pumps coupled to humidification-dehumidification systems for simultaneous cooling and desalination. Also, the present system operates flexibly to switch between desalination and cooling mode (mode-1) to cooling mode (mode-2). Towards this, a mathematical model of the system has been developed and analyzed under various operating conditions. The system's performance, which includes desalination yield, cooling output, gained output ratio, and coefficient of performance under each mode of operation, is studied for different ambient conditions and evaporator temperatures. The maximum desalination yield, cooling output, gained output ratio, and coefficient of performance of mode-1 are 4.55 LPH, 0.82 kWth, 3.79, and 0.75, respectively. The maximum cooling output and COP of mode-2 are 3.79 kWth and 3.82, respectively. The exergy efficiencies for mode-1 and mode-2 are 32.7 % and 29.7 %, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Augmentation of solar-assisted humidification-dehumidification water desalination system using heat recovery and thermal energy storage system
    Fouda, Ali
    Nada, Sameh A.
    Bin Mahfouz, Abdullah S.
    Al-Zahrani, A.
    Elattar, Hassan F.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (08) : 6631 - 6650
  • [42] Experimental investigation on the photovoltaic-thermal solar heat pump air-conditioning system on water-heating mode
    Fang, Guiyin
    Hu, Hainan
    Liu, Xu
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (06) : 736 - 743
  • [43] Refrigerant Flow Distribution Research for Battery Cooling Coupled With Cabin Comfort Based on Dual-Evaporator Heat Pump System for Electric Vehicle Acceleration
    Wang, Yan
    Wang, Hewu
    Gao, Qing
    Zhang, Xiaohang
    Zhang, Xilong
    Liu, Zunmin
    JOURNAL OF ELECTROCHEMICAL ENERGY CONVERSION AND STORAGE, 2023, 20 (03)
  • [44] Experimental study on the operating characteristics of a novel photovoltaic/thermal integrated dual-source heat pump water heating system
    Qu, Minglu
    Chen, Jianbo
    Nie, Linjie
    Li, Fengshu
    Yu, Qian
    Wang, Tan
    APPLIED THERMAL ENGINEERING, 2016, 94 : 819 - 826
  • [45] Anomaly detection using convolutional autoencoder with residual gated recurrent unit and weak supervision for photovoltaic thermal heat pump system
    John, Lukudu Samuel
    Yoon, Sungmin
    Li, Jiteng
    Wang, Peng
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [46] A new ground-coupled heat pump system integrated with a multi-mode air-source heat compensator to eliminate thermal imbalance in cold regions
    You, Tian
    Shi, Wenxing
    Wang, Baolong
    Wu, Wei
    Li, Xianting
    ENERGY AND BUILDINGS, 2015, 107 : 103 - 112
  • [47] A WIRELESS DUAL-MODE MICRO THERMAL FLOW SENSOR SYSTEM WITH EXTENDED FLOW RANGE BY USING 0.18μm CMOS-MEMS PROCESS
    Xu, Wei
    Lijin, Beiqi
    Duan, Mingzheng
    Wang, Xiaoyi
    Wicaksana, Jeffry
    Min, A.
    Ahmed, Moaaz
    Wang, Ruijin
    Fang, Nicholas Xuanlai
    Bermak, Amine
    Lee, Yi-Kuen
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 824 - 827
  • [48] Solid desiccant air conditioning system using desiccant dehumidifiers with cooling technique and thermal recovery unit: Experimental investigation and performance analysis
    Abdelgaied, Mohamed
    Saber, Mohamed A.
    Bassuoni, M. M.
    Khaira, Ahmad M.
    JOURNAL OF CLEANER PRODUCTION, 2023, 421
  • [49] Modeling-Based Energy Performance Assessment and Validation of Air-To-Water Heat Pump System Integrated with Multi-Span Greenhouse on Cooling Mode
    Rasheed, Adnan
    Kim, Hyeon Tae
    Lee, Hyun Woo
    AGRONOMY-BASEL, 2022, 12 (06):
  • [50] Feasibility study of small-scale gas engine integrated with innovative net-zero water desiccant cooling system and single-effect thermal desalination unit
    Asadi, Ashkan
    Meratizaman, Mousa
    Hosseinjani, Ali Akbar
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 119 : 276 - 293