Endovascular repair of thoracic aortic disease with isolated left vertebral artery and unfavorable proximal landing zone using fenestrated castor stent-graft

被引:0
|
作者
Wang, Zhenhua [1 ,2 ]
Fang, Changcun [1 ,2 ]
Song, Han [1 ,2 ]
Wei, Duoliang [1 ,2 ]
Meng, Xiangbin [1 ,2 ]
Bai, Xiao [1 ,2 ]
Liu, Chunxiao [1 ,2 ]
Zhao, Xin [1 ,2 ]
机构
[1] Shandong Univ, Dept Cardiovasc Surg, Qilu Hosp, Jinan, Peoples R China
[2] Shandong Univ, Inst Thoracoscopy Cardiac Surg, Jinan, Peoples R China
来源
关键词
isolated left vertebral artery; unfavorable proximal landing zone; castor single-branched stent-graft; fenestrated technique; thoracic aortic disease; LEFT SUBCLAVIAN ARTERY; TOTAL ARCH REPLACEMENT; SINGLE-BRANCHED STENT; IN-SITU FENESTRATION; DISSECTION;
D O I
10.3389/fcvm.2023.1168180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveThe main purpose of this study was to evaluate the safety and efficacy of Castor single-branched stent-graft combined with fenestrated technique in treatment of thoracic aortic disease (TAD) with unfavorable proximal landing area (PLZ) and isolated left vertebral artery (ILVA).MethodsFrom January 2018 to March 2022, 8 patients with TAD (6 patients with type B aortic dissections, 1 patient with type B intramural hematomas, and 1 patient with thoracic aortic aneurysm) underwent thoracic endovascular aortic repair with fenestrated Castor stent-graft due to the existence of ILVA and unfavorable PLZ. Demographic characteristics, surgical details, postoperative complications, follow-up and postoperative CTA imaging results were collected and analyzed.ResultsThe primary technical success rate was 100%. The mean operation time was 115 min (range, 70-180 min). All the left subclavian arteries (LSAs) and ILVAs of the eight patients were revascularized by fenestrated Castor stent-grafts. During the follow-up period, no deaths and complications were observed. No internal leakage, aortic rupture, retrograde type A dissection were found on computed tomography angiography. All of the LSAs and ILVAs maintained patency without stenosis.ConclusionCastor single-branched stent-graft implantation combined with fenestration technique may be safe and feasible for TAD patients with ILVA and unfavorable PLZ.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Long-Term Outcomes of Thoracic Endovascular Repair for Aortic Arch Dissection Using Customized Single-Branched Fenestrated Stent-Graft
    Li, Xiaoye
    Zhang, Lei
    Song, Chao
    Zhang, Hao
    Xia, Shibo
    Li, Haiyan
    Jing, Zaiping
    Lu, Qingsheng
    VASCULAR AND ENDOVASCULAR SURGERY, 2021, 55 (06) : 577 - 585
  • [42] Dislocation of a stent-graft into the aortic arch during endovascular repair of a descending thoracic aortic aneurysm
    Augustin, N
    Bauernschmitt, R
    Hausleiter, J
    Lange, R
    ANNALS OF THORACIC SURGERY, 2006, 81 (04): : 1502 - 1505
  • [43] Endovascular repair of thoracic aortic aneurysms: Stent-graft fixation across the aortic arch vessels
    Burks, JA
    Faries, PL
    Gravereaux, EC
    Hollier, LH
    Marin, ML
    ANNALS OF VASCULAR SURGERY, 2002, 16 (01) : 24 - 28
  • [44] Endovascular repair for a descending thoracic aortic aneurysm with a stent-graft covering the celiac artery: Report of two cases
    Hiroyuki Ishibashi
    Tsuneo Ishiguchi
    Takashi Ohta
    Ikuo Sugimoto
    Jun Kawanishi
    Tetsuya Yamada
    Noriyuki Hida
    Seiji Kamei
    Surgery Today, 2009, 39 : 518 - 522
  • [45] Endovascular repair for a descending thoracic aortic aneurysm with a stent-graft covering the celiac artery: Report of two cases
    Ishibashi, Hiroyuki
    Ishiguchi, Tsuneo
    Ohta, Takashi
    Sugimoto, Ikuo
    Kawanishi, Jun
    Yamada, Tetsuya
    Hida, Noriyuki
    Kamei, Seiji
    SURGERY TODAY, 2009, 39 (06) : 518 - 522
  • [46] On stent-graft models in thoracic aortic endovascular repair: A computational investigation of the hemodynamic factors
    Fung, George S. K.
    Lam, S. K.
    Cheng, Stephen W. K.
    Chow, K. W.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (04) : 484 - 489
  • [47] Thoracic Endovascular Aortic Repair for Challenging Aortic Arch Diseases Using Fenestrated Stent Grafts From Zone 0
    Kurimoto, Yoshihiko
    Maruyama, Ryushi
    Ujihira, Kousuke
    Nishioka, Naritomo
    Hasegawa, Kousei
    Iba, Yutaka
    Hatta, Eiichiro
    Yamada, Akira
    Nakanishi, Katsuhiko
    ANNALS OF THORACIC SURGERY, 2015, 100 (01): : 24 - 33
  • [48] Early results of a low-profile stent-graft for thoracic endovascular aortic repair
    El Beyrouti, Hazem
    Lescan, Mario
    Doemland, Marco
    Mustafi, Migdat
    Jungmann, Florian
    Jorg, Tobias
    Halloum, Nancy
    Dorweiler, Bernhard
    PLOS ONE, 2020, 15 (11):
  • [49] Hemodynamic effects of stent-graft introducer sheath during thoracic endovascular aortic repair
    Qiao, Yonghui
    Mao, Le
    Wang, Yan
    Luan, Jingyang
    Chen, Yanlu
    Zhu, Ting
    Luo, Kun
    Fan, Jianren
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2022, 21 (02) : 419 - 431
  • [50] A Stent-Graft Fracture After a 14-Year Thoracic Endovascular Aortic Repair
    Wu, Wenhui
    Pu, Junzhou
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (09) : 1413 - 1415