Endovascular repair of thoracic aortic disease with isolated left vertebral artery and unfavorable proximal landing zone using fenestrated castor stent-graft

被引:0
|
作者
Wang, Zhenhua [1 ,2 ]
Fang, Changcun [1 ,2 ]
Song, Han [1 ,2 ]
Wei, Duoliang [1 ,2 ]
Meng, Xiangbin [1 ,2 ]
Bai, Xiao [1 ,2 ]
Liu, Chunxiao [1 ,2 ]
Zhao, Xin [1 ,2 ]
机构
[1] Shandong Univ, Dept Cardiovasc Surg, Qilu Hosp, Jinan, Peoples R China
[2] Shandong Univ, Inst Thoracoscopy Cardiac Surg, Jinan, Peoples R China
来源
关键词
isolated left vertebral artery; unfavorable proximal landing zone; castor single-branched stent-graft; fenestrated technique; thoracic aortic disease; LEFT SUBCLAVIAN ARTERY; TOTAL ARCH REPLACEMENT; SINGLE-BRANCHED STENT; IN-SITU FENESTRATION; DISSECTION;
D O I
10.3389/fcvm.2023.1168180
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveThe main purpose of this study was to evaluate the safety and efficacy of Castor single-branched stent-graft combined with fenestrated technique in treatment of thoracic aortic disease (TAD) with unfavorable proximal landing area (PLZ) and isolated left vertebral artery (ILVA).MethodsFrom January 2018 to March 2022, 8 patients with TAD (6 patients with type B aortic dissections, 1 patient with type B intramural hematomas, and 1 patient with thoracic aortic aneurysm) underwent thoracic endovascular aortic repair with fenestrated Castor stent-graft due to the existence of ILVA and unfavorable PLZ. Demographic characteristics, surgical details, postoperative complications, follow-up and postoperative CTA imaging results were collected and analyzed.ResultsThe primary technical success rate was 100%. The mean operation time was 115 min (range, 70-180 min). All the left subclavian arteries (LSAs) and ILVAs of the eight patients were revascularized by fenestrated Castor stent-grafts. During the follow-up period, no deaths and complications were observed. No internal leakage, aortic rupture, retrograde type A dissection were found on computed tomography angiography. All of the LSAs and ILVAs maintained patency without stenosis.ConclusionCastor single-branched stent-graft implantation combined with fenestration technique may be safe and feasible for TAD patients with ILVA and unfavorable PLZ.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Homemade proximal scalloped stent graft for thoracic endovascular aortic repair of zone 2 acute aortic syndrome
    Canaud, Ludovic
    Gandet, Thomas
    Khantalin, Ilya
    Ozdemir, Baris Ata
    Marty-Ane, Charles-Henri
    Alric, Pierre
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2016, 152 (05): : 1301 - 1306
  • [32] Endovascular Repair for Acute Type B Aortic Dissection With Unfavorable Proximal Landing Zone
    Chang, Haiyang
    Wang, Yongzheng
    Liu, Bin
    Wang, Wujie
    Li, Yuliang
    ANNALS OF THORACIC SURGERY, 2022, 113 (02): : 545 - 553
  • [33] Factors favoring stent-graft collapse after thoracic endovascular aortic repair
    Canaud, Ludovic
    Alric, Pierre
    Desgranges, Pascal
    Marzelle, Jean
    Marty-Ane, Charles
    Becquemin, Jean-Pierre
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05): : 1153 - 1157
  • [34] Outcomes of thoracic endovascular aortic repair for penetrating aortic ulcers involving the left subclavian artery with the Castor single-branched stent graft
    Huang, Ben
    Jia, Hao
    Lai, Hao
    Chen, Zhenhang
    Sun, Yongxin
    Wang, Chunsheng
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 62 (02)
  • [35] The Effect of Proximal Landing Zone on Stroke and Mortality in Thoracic Endovascular Aortic Repair
    Ma, Yuchi
    Siddiqui, Mishal
    Farhan, Syed
    Albuquerque, Francisco
    Larson, Robert
    Levy, Mark
    Chery, Josue
    Newton., Daniel
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (03) : E18 - E18
  • [36] Outcomes of thoracic endovascular aortic repair with fenestrated surgeon-modified stent-graft for type B aortic dissections involving the aortic arch
    Li, Xiaoye
    Zhang, Lei
    Song, Chao
    Zhang, Hao
    Xia, Shibo
    Yang, Yang
    Zhu, Longtu
    Guo, Wenying
    Lu, Qingsheng
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [37] Haemodynamics of Different Configurations of a Left Subclavian Artery Stent Graft for Thoracic Endovascular Aortic Repair
    Tricarico, Rosamaria
    Tran-Son-Tay, Roger
    Laquian, Liza
    Scali, Salvatore T.
    Lee, Teng-Chun
    Beck, Adam W.
    Berceli, Scott A.
    He, Yong
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 59 (01) : 7 - 15
  • [38] Handmade stent graft fenestration to preserve left subclavian artery in thoracic endovascular aortic repair
    Kuo, Huey-Shiuan
    Huang, Jih-Hsin
    Chen, Jer-Shen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2019, 56 (03) : 587 - 594
  • [39] Improved Outcomes of Thoracic Endovascular Aortic Repair Using Fenestrated Stent Graft from Zone 0 for Challenging Distal Aortic Arch Aneurysms
    Miura, Shuhei
    Kurimoto, Yoshihiko
    Maruyama, Ryushi
    Wada, Takuya
    Konno, Mitsuhiko
    Iba, Yutaka
    Hatta, Eiichiro
    Yamada, Akira
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (06) : E82 - E82
  • [40] Commentary: How to transpose the isolated left vertebral artery in hybrid thoracic endovascular aortic repair
    Asai, Tohru
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (06): : 2199 - 2199