Cement Augmented Pedicle Screw Instrumentation in Pediatric Spine Surgery

被引:1
|
作者
Mraja, Hamisi Mwarindano [1 ]
Gok, Halil [1 ]
Daadour, Inas Mohamed Fawzy [1 ]
Ulusoy, Onur Levent [2 ]
Sanli, Tunay [1 ]
Karadereler, Selhan [1 ]
Enercan, Meric [3 ]
Hamzaoglu, Azmi [1 ]
机构
[1] Scoliosis Spine Ctr Istanbul, Istanbul, Turkiye
[2] Istanbul Florence Nightingale Hosp, Radiol Dept, Istanbul, Turkiye
[3] Demiroglu Bilim Univ, Scoliosis Spine Ctr Istanbul, Istanbul, Turkiye
关键词
Cement augmentation; Osteoporosis; Pediatric scoliosis; Pedicle screw; Vertebroplasty; BONE-MINERAL DENSITY; PERCUTANEOUS VERTEBROPLASTY; POLYMETHYLMETHACRYLATE; OSTEOPOROSIS; CHILDREN; ADOLESCENTS; FIXATION;
D O I
10.1016/j.wneu.2023.03.006
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
-BACKGROUND: Osteoporosis in pediatric patients is rare. Osteomalacia and osteoporosis are known to develop in syndromic or neuromuscular scoliosis children. Spinal deformity surgery for pediatric patients with osteoporosis is challenging, associated with pedicle screw (PS) failure and compression fractures. Cement augmentation of PS is one several measures to prevent screw failure. It provides additional pull-out strength to the PS in the osteoporotic vertebra. METHODS: In 2010-2020, an analysis of pediatric pa-tients who had cement augmentation of PS with a minimum follow-up of 2 years was performed. Radiological and clinical evaluations were analyzed. RESULTS: The study included 7 patients (4 girls, 3 boys) with a mean age of 13 years (range, 10-14 years) and mean follow-up of 3 years (range, 2-3 years). Only 2 patients -nderwent revision surgery. Total number of cement augmented PSs was 52 with an average of 7 per patient. Only 1 patient had lower instrumented vertebra verte-broplasty. There was no PS pull-out in the cement augmented levels, and there were no neurological deficits or pulmonary cement embolisms. One patient developed a PS pull-out in uncemented levels. Two patients developed compression fractures, one, with osteogenesis imperfecta, in the supra-adjacent levels (upper instrumented vertebra + 1 and upper instrumented vertebra + 2), and the other, with neuromuscular scoliosis, in the uncemented segments. -CONCLUSIONS: In this study, all cement augmented PSs provided satisfactory radiological outcomes without PS pull-out and adjacent vertebral compression fracture. In pediatric spine surgery, in osteoporotic patients with a poor bone purchase, cement augmentation may be used, especially in high-risk patients with osteogenesis imper-fecta, neuromuscular scoliosis, and syndromic scoliosis.
引用
收藏
页码:E126 / E130
页数:5
相关论文
共 50 条
  • [41] Pedicle screw augmentation in posterior constructs of the thoracolumbar spine: How many pedicle screws should be augmented?
    Spicher, Anna
    Lindtner, Richard Andreas
    Zegg, Michael Josef
    Schmid, Rene
    Hoermann, Romed
    Schmoelz, Werner
    CLINICAL BIOMECHANICS, 2023, 106
  • [42] PEDICLE SCREW FIXATION IN THE SPINE
    MULHOLLAND, RC
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04): : 517 - 519
  • [43] Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
    Tang, Yong-chao
    Guo, Hui-zhi
    Guo, Dan-qing
    Luo, Pei-jie
    Li, Yong-xian
    Mo, Guo-ye
    Ma, Yan-huai
    Peng, Jian-cheng
    Liang, De
    Zhang, Shun-cong
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [44] Effect and potential risks of using multilevel cement-augmented pedicle screw fixation in osteoporotic spine with lumbar degenerative disease
    Yong-chao Tang
    Hui-zhi Guo
    Dan-qing Guo
    Pei-jie Luo
    Yong-xian Li
    Guo-ye Mo
    Yan-huai Ma
    Jian-cheng Peng
    De Liang
    Shun-cong Zhang
    BMC Musculoskeletal Disorders, 21
  • [45] Reduced cement volume does not affect screw stability in augmented pedicle screws
    Weiser, Lukas
    Sellenschloh, Kay
    Pueschel, Klaus
    Morlock, Michael M.
    Viezens, Lennart
    Lehmann, Wolfgang
    Huber, Gerd
    EUROPEAN SPINE JOURNAL, 2020, 29 (06) : 1297 - 1303
  • [46] Reduced cement volume does not affect screw stability in augmented pedicle screws
    Lukas Weiser
    Kay Sellenschloh
    Klaus Püschel
    Michael M. Morlock
    Lennart Viezens
    Wolfgang Lehmann
    Gerd Huber
    European Spine Journal, 2020, 29 : 1297 - 1303
  • [47] Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws
    Mueller, Jan U.
    Baldauf, Joerg
    Marx, Sascha
    Kirsch, Michael
    Schroeder, Henry W. S.
    Pillich, Dirk T.
    JOURNAL OF NEUROSURGERY-SPINE, 2016, 25 (01) : 103 - 109
  • [48] In vitro flexibility of an experimental pedicle screw and plate instrumentation system on the porcine lumbar spine
    Lysack, JT
    Yen, D
    Dumas, GA
    MEDICAL ENGINEERING & PHYSICS, 2000, 22 (07) : 461 - 468
  • [49] Intracardiac, pulmonary cement embolism in a 67-year-old female after cement-augmented pedicle screw instrumentation: A case report and review of literature
    Tong-Zhou Liang
    Hai-Peng Zhu
    Bo Gao
    Yan Peng
    Wen-Jie Gao
    World Journal of Clinical Cases, 2021, 9 (13) : 3120 - 3129
  • [50] Biomechanics of transfixation in pedicle screw instrumentation
    Lim, TH
    Eck, JC
    An, HS
    Hong, JH
    Ahn, JY
    You, JW
    SPINE, 1996, 21 (19) : 2224 - 2229