Flexible Versus Rigid Laryngoscopy: A Prospective, Blinded Comparison of Image Quality

被引:2
|
作者
Boles, Roger W. [1 ]
Gao, William Z. [2 ]
Johns, Michael M. [3 ]
Daniero, James J. [4 ]
Grant, Nazaneen N. [5 ]
Rubin, Adam D. [6 ]
Bhatt, Neel K. [7 ,8 ]
Hapner, Edie R. [3 ,9 ]
O'Dell, Karla [3 ,10 ]
机构
[1] USC, Keck Sch Med, Los Angeles, CA USA
[2] Georgetown Univ Med Ctr, Dept Otolaryngol Head & Neck Surg, Washington, DC USA
[3] Univ Southern Calif, Dept Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[4] Univ Virginia Hlth Syst, Dept Otolaryngol Head & Neck Surg, Charlottesville, VA USA
[5] Georgetown Univ, Med Sch, Dept Otolaryngol Head & Neck Surg, Washington, DC USA
[6] Lakeshore Ears Nose Throat Ctr, St Clair Shores, MI USA
[7] Univ Southern Calif, Dept Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[8] Univ Washington, Dept Otolaryngol Head & Neck Surg, Seattle, WA USA
[9] Univ Alabama Birmingham, Dept Otolaryngol Head & Neck Surg, Birmingham, AL USA
[10] 1540 Alcazar St,CHP 204M,Hlth Sci Campus, Los Angeles, CA 90033 USA
关键词
Indirect laryngoscopy; Flexible laryngoscopy; Rigid laryngoscopy; Image quality; Diagnostic ability;
D O I
10.1016/j.jvoice.2021.02.010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective. To compare flexible distal-chip laryngoscopy (FDL) and rigid telescopic laryngoscopy (RTL) in image quality and diagnostic ability. Study Design. Prospective cohort study; blinded comparison. Methods. Eighteen normal adult subjects were recruited to undergo both FDL and RTL and normalized videos were recorded. Three blinded laryngologists compared the videos for color fidelity, illumination, resolution, and vascularity, and indicated superiority with FDL, RTL, or no difference. Raters also reported if an abnormality was seen and in which video it was better visualized. Videos for two subjects were repeated to assess intra-rater reliability, making 20 video comparisons across 3 raters for a total of 60 ratings. Differences in responses were analyzed via Mann-Whitney U and Pearson X2. Inter-rater reliability was assessed via Fleiss' kappa, and intra-rater reliability was assessed via percent agreement. Results. RTL was rated superior in all categories of image quality (47 vs 5 vs 8, P < 0.01; 47 vs 7 vs 6, P < 0.01; 51 vs 5 vs 4, P<0.01; 44 vs 9 vs 7, P < 0.01, respectively). An abnormality was seen 33 times with both modalities and 6 times with RTL only. When seen with both modalities, visualization was superior in RTL compared with FDL (29 vs 4, P <0.01). Conclusions. There was significant superiority of RTL in all categories of image quality, with slight inter-rater agreement for color fidelity, resolution, and vascularity. RTL was also significantly better for visualization of abnormalities. These findings suggest superior image quality in RTL compared with FDL, but further research is required to determine if this difference is clinically significant.
引用
收藏
页码:440 / 443
页数:4
相关论文
共 50 条
  • [1] Reliability of the reflux finding score for infants in flexible versus rigid laryngoscopy
    Singendonk, Maartje M. J.
    Pullens, Bas
    van Heteren, Jan A. A.
    de Gier, Henriette H. W.
    Hoeve, Hans L. J.
    Konig, Astrid M.
    van der Schroeff, Marc P.
    Hoekstra, Carlijn E. L.
    Veder, Laura L.
    van der Pol, Rachel J.
    Benninga, Marc A.
    van Wijk, Michiel P.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2016, 86 : 37 - 42
  • [2] Flexible versus rigid laryngoscopy and stroboscopy. Different findings in voice defects
    Schade, G
    Hess, M
    HNO, 2001, 49 (07) : 562 - 568
  • [3] Flexible versus rigid laryngoscopy: A randomized crossover study comparing patient experience
    Clark, Bhavishya S.
    Gao, William Z.
    Bertelsen, Caitlin
    Choi, Janet S.
    Hagit, Shoffel-Havakuk
    Reder, Lindsay S.
    Hapner, Edie R.
    Johns, Michael M.
    O'Dell, Karla
    LARYNGOSCOPE, 2020, 130 (11): : 2663 - 2666
  • [4] Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality
    Broeders, Mireille J. M.
    ten Voorde, Marloes
    Veldkamp, Wouter J. H.
    van Engen, Ruben E.
    van Landsveld-Verhoeven, Cary
    't Jong-Gunneman, Machteld N. L.
    de Win, Jos
    Droogh-de Greve, Kitty
    Paap, Ellen
    den Heeten, Gerard J.
    EUROPEAN RADIOLOGY, 2015, 25 (03) : 821 - 829
  • [5] Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality
    Mireille J. M. Broeders
    Marloes ten Voorde
    Wouter J. H. Veldkamp
    Ruben E. van Engen
    Cary van Landsveld – Verhoeven
    Machteld N. L. ’t Jong – Gunneman
    Jos de Win
    Kitty Droogh-de Greve
    Ellen Paap
    Gerard J. den Heeten
    European Radiology, 2015, 25 : 821 - 829
  • [6] Which one is favorable in the elderly? Transoral rigid laryngoscopy or transnasal flexible fiberoptic laryngoscopy
    Tulaci, Kamil Gokce
    Arslan, Erhan
    Tulaci, Tugba
    Yazici, Hasmet
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2020, 41 (06)
  • [7] Flexible versus rigid intrauterine insemination catheters: A prospective, randomized, controlled study
    Miller, PB
    Acres, ML
    Proctor, JG
    Higdon, HL
    Boone, WR
    FERTILITY AND STERILITY, 2005, 83 (05) : 1544 - 1546
  • [8] Flexible versus rigid endoscopes for outpatient hysteroscopy: a prospective randomized clinical trial
    Unfried, G
    Wieser, F
    Albrecht, A
    Kaider, A
    Nagele, F
    HUMAN REPRODUCTION, 2001, 16 (01) : 168 - 171
  • [9] Flexible versus rigid intrauterine insemination catheters: A prospective, randomized, controlled study
    Miller, PB
    Acres, ML
    Proctor, JG
    Higdon, HL
    Boone, WR
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 86S - 86S
  • [10] FLEXIBLE VERSUS RIGID SIGMOIDOSCOPY - A COMPARISON OF FINDINGS AND TOLERANCE IN ASYMPTOMATIC VETERANS
    CHATTERJI, AN
    GOPALSWAMY, N
    TRULZSCH, D
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1984, 79 (10): : 810 - 810