Flexible Versus Rigid Laryngoscopy: A Prospective, Blinded Comparison of Image Quality

被引:2
|
作者
Boles, Roger W. [1 ]
Gao, William Z. [2 ]
Johns, Michael M. [3 ]
Daniero, James J. [4 ]
Grant, Nazaneen N. [5 ]
Rubin, Adam D. [6 ]
Bhatt, Neel K. [7 ,8 ]
Hapner, Edie R. [3 ,9 ]
O'Dell, Karla [3 ,10 ]
机构
[1] USC, Keck Sch Med, Los Angeles, CA USA
[2] Georgetown Univ Med Ctr, Dept Otolaryngol Head & Neck Surg, Washington, DC USA
[3] Univ Southern Calif, Dept Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[4] Univ Virginia Hlth Syst, Dept Otolaryngol Head & Neck Surg, Charlottesville, VA USA
[5] Georgetown Univ, Med Sch, Dept Otolaryngol Head & Neck Surg, Washington, DC USA
[6] Lakeshore Ears Nose Throat Ctr, St Clair Shores, MI USA
[7] Univ Southern Calif, Dept Otolaryngol Head & Neck Surg, Los Angeles, CA USA
[8] Univ Washington, Dept Otolaryngol Head & Neck Surg, Seattle, WA USA
[9] Univ Alabama Birmingham, Dept Otolaryngol Head & Neck Surg, Birmingham, AL USA
[10] 1540 Alcazar St,CHP 204M,Hlth Sci Campus, Los Angeles, CA 90033 USA
关键词
Indirect laryngoscopy; Flexible laryngoscopy; Rigid laryngoscopy; Image quality; Diagnostic ability;
D O I
10.1016/j.jvoice.2021.02.010
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective. To compare flexible distal-chip laryngoscopy (FDL) and rigid telescopic laryngoscopy (RTL) in image quality and diagnostic ability. Study Design. Prospective cohort study; blinded comparison. Methods. Eighteen normal adult subjects were recruited to undergo both FDL and RTL and normalized videos were recorded. Three blinded laryngologists compared the videos for color fidelity, illumination, resolution, and vascularity, and indicated superiority with FDL, RTL, or no difference. Raters also reported if an abnormality was seen and in which video it was better visualized. Videos for two subjects were repeated to assess intra-rater reliability, making 20 video comparisons across 3 raters for a total of 60 ratings. Differences in responses were analyzed via Mann-Whitney U and Pearson X2. Inter-rater reliability was assessed via Fleiss' kappa, and intra-rater reliability was assessed via percent agreement. Results. RTL was rated superior in all categories of image quality (47 vs 5 vs 8, P < 0.01; 47 vs 7 vs 6, P < 0.01; 51 vs 5 vs 4, P<0.01; 44 vs 9 vs 7, P < 0.01, respectively). An abnormality was seen 33 times with both modalities and 6 times with RTL only. When seen with both modalities, visualization was superior in RTL compared with FDL (29 vs 4, P <0.01). Conclusions. There was significant superiority of RTL in all categories of image quality, with slight inter-rater agreement for color fidelity, resolution, and vascularity. RTL was also significantly better for visualization of abnormalities. These findings suggest superior image quality in RTL compared with FDL, but further research is required to determine if this difference is clinically significant.
引用
收藏
页码:440 / 443
页数:4
相关论文
共 50 条
  • [21] Visual rigid laryngoscopy versus video laryngoscopy for endotracheal intubation in elderly patients: A randomized controlled trial
    Weng, Lijun
    Yu, Binmei
    Ding, Lan
    Shi, Menglu
    Wang, Tingjie
    Li, Zengqiang
    Qiu, Weihuang
    Lin, Xianzhong
    Lin, Bo
    Gao, Youguang
    PLOS ONE, 2024, 19 (10):
  • [22] A COMPARISON OF RIGID AND FLEXIBLE SIGMOIDOSCOPY
    GARDNER, RC
    SWENY, SE
    KANTROWITZ, PA
    GASTROINTESTINAL ENDOSCOPY, 1980, 26 (02) : 67 - 67
  • [23] RECTOSCOPE - RIGID OR FLEXIBLE - A COMPARISON
    CLASSEN, M
    PHILLIP, J
    KNYRIM, K
    HERTEL, H
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1985, 110 (12) : 445 - 448
  • [24] Blinded Evaluation of Interrater Reliability of an Operative Competency Assessment Tool for Direct Laryngoscopy and Rigid Bronchoscopy
    Ishman, Stacey L.
    Benke, James R.
    Johnson, Kaalan Erik
    Zur, Karen B.
    Jacobs, Ian N.
    Thorne, Marc C.
    Brown, David J.
    Lin, Sandra Y.
    Bhatti, Nasir
    Deutsch, Ellen S.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2012, 138 (10) : 916 - 922
  • [25] Distal chip versus fiberoptic laryngoscopy using endoscopic sheaths: diagnostic accuracy and image quality
    Boudewijn E. C. Plaat
    Bernard F. A. M. van der Laan
    Jan Wedman
    György B. Halmos
    Frederik G. Dikkers
    European Archives of Oto-Rhino-Laryngology, 2014, 271 : 2227 - 2232
  • [26] INTRAOPERATIVE ASSESSMENT OF COLORECTAL ANASTOMOSES: A COMPARISON OF FLEXIBLE ENDOSCOPY VERSUS RIGID SIGMOIDOSCOPY
    Paraoan, Marius
    Loganathan, Santosh
    Kumar, Gautam
    Singh, Amital
    GUT, 2021, 70 : A202 - A202
  • [27] Oral dyclonine hydrochloride mucilage versus tetracaine spray in electronic flexible laryngoscopy: A prospective, randomized controlled trial
    Sha Jichao
    Meng Cuida
    Chen Mingxing
    Wang Yunyun
    Zhu Dongdong
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2016, 37 (02) : 169 - 171
  • [28] Distal chip versus fiberoptic laryngoscopy using endoscopic sheaths: diagnostic accuracy and image quality
    Plaat, Boudewijn E. C.
    van der Laan, Bernard F. A. M.
    Wedman, Jan
    Halmos, Gyorgy B.
    Dikkers, Frederik G.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2014, 271 (08) : 2227 - 2232
  • [29] A Comparison of GlideScope Video Laryngoscopy Versus Direct Laryngoscopy Intubation in the Emergency Department
    Platts-Mills, Timothy F.
    Campagne, Danielle
    Chinnock, Brian
    Snowden, Brandy
    Glickman, Larry T.
    Hendey, Gregory W.
    ACADEMIC EMERGENCY MEDICINE, 2009, 16 (09) : 866 - 871
  • [30] Flexible versus rigid tile assembly
    Jonoska, Natasa
    McColm, Gregory L.
    UNCONVENTIONAL COMPUTATION, PROCEEDINGS, 2006, 4135 : 139 - 151