Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality

被引:0
|
作者
Mireille J. M. Broeders
Marloes ten Voorde
Wouter J. H. Veldkamp
Ruben E. van Engen
Cary van Landsveld – Verhoeven
Machteld N. L. ’t Jong – Gunneman
Jos de Win
Kitty Droogh-de Greve
Ellen Paap
Gerard J. den Heeten
机构
[1] Dutch Reference Centre for Screening,Department for Health Evidence
[2] Radboud University Medical Center,Department of Radiology
[3] Organization for Cancer Screening in the Eastern Part of the Netherlands,undefined
[4] Leiden University Medical Center,undefined
[5] Gelre Hospital Apeldoorn,undefined
[6] Department of Radiology,undefined
[7] Academic Medical Centre,undefined
来源
European Radiology | 2015年 / 25卷
关键词
Mammography; Compression paddle; Performance; Flexible compression paddle; Rigid compression paddle;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:821 / 829
页数:8
相关论文
共 50 条
  • [1] Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality
    Broeders, Mireille J. M.
    ten Voorde, Marloes
    Veldkamp, Wouter J. H.
    van Engen, Ruben E.
    van Landsveld-Verhoeven, Cary
    't Jong-Gunneman, Machteld N. L.
    de Win, Jos
    Droogh-de Greve, Kitty
    Paap, Ellen
    den Heeten, Gerard J.
    EUROPEAN RADIOLOGY, 2015, 25 (03) : 821 - 829
  • [2] Mammography with and without radiolucent positioning sheets: Comparison of projected breast area, pain experience, radiation dose and technical image quality
    Timmers, Janine
    ten Voorde, Marloes
    van Engen, Ruben E.
    van Landsveld-Verhoeven, Cary
    Pijnappel, Ruud
    Droogh-de Greve, Kitty
    den Heeten, Gerard J.
    Broeders, Mireille J. M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1903 - 1909
  • [3] Technical Note: Validation of two methods to determine contact area between breast and compression paddle in mammography
    Branderhorst, Woutjan
    de Groot, Jerry E.
    van Lier, Monique G. J. T. B.
    Highnam, Ralph P.
    den Heeten, Gerard J.
    Grimbergen, Cornelis A.
    MEDICAL PHYSICS, 2017, 44 (08) : 4040 - 4044
  • [4] Flexible Versus Rigid Laryngoscopy: A Prospective, Blinded Comparison of Image Quality
    Boles, Roger W.
    Gao, William Z.
    Johns, Michael M.
    Daniero, James J.
    Grant, Nazaneen N.
    Rubin, Adam D.
    Bhatt, Neel K.
    Hapner, Edie R.
    O'Dell, Karla
    JOURNAL OF VOICE, 2023, 37 (03) : 440 - 443
  • [5] Dedicated breast CT: Radiation dose and image quality evaluation
    Boone, JM
    Nelson, TR
    Lindfors, KK
    Seibert, JA
    RADIOLOGY, 2001, 221 (03) : 657 - 667
  • [6] Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality
    O'Connell, Avice
    Conover, David L.
    Zhang, Yan
    Seifert, Posy
    Logan-Young, Wende
    Lin, Chuen-Fu Linda
    Sahler, Lawrence
    Ning, Ruola
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 496 - 509
  • [7] RELATIONSHIP BETWEEN RADIATION DOSE AND IMAGE QUALITY IN DIGITAL BREAST TOMOSYNTHESIS
    Alakhras, Maram M.
    Mello-Thoms, Claudia
    Bourne, Roger
    Rickard, Mary
    Diffey, Jennifer
    Brennan, Patrick C.
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (04) : 351 - 360
  • [8] Effects of Reduced Compression in Digital Breast Tomosynthesis on Pain, Anxiety, and Image Quality
    Suhaimi, Siti Aishah Abdullah
    Mohamed, Afifah
    Ahmad, Mahadir
    Chelliah, Kanaga Kumari
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2015, 22 (06): : 40 - 46
  • [9] BREAST THICKNESS IN ROUTINE MAMMOGRAMS - EFFECT ON IMAGE QUALITY AND RADIATION-DOSE
    HELVIE, MA
    CHAN, HP
    ADLER, DD
    BOYD, PG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (06) : 1371 - 1374
  • [10] COMPARISON OF IMAGE QUALITY AND MEAN ABSORBED DOSE TO THE BREAST FOR 2 MAMMOGRAPHIC FILMS
    PERSLIDEN, J
    FRANSSON, V
    VITAK, B
    FAGERBERG, G
    ACTA RADIOLOGICA, 1993, 34 (04) : 351 - 355