Treatment of severe tricuspid regurgitation induced by permanent pacemaker lead: Transcatheter tricuspid valve replacement with the guidance of 3-dimensional printing

被引:11
|
作者
Mao, Yu [1 ]
Liu, Yang [1 ]
Meng, Xin [2 ]
Ma, Yanyan [1 ]
Li, Lanlan [1 ]
Zhai, Mengen [1 ]
Jin, Ping [1 ]
Lu, Fanglin [3 ]
Yang, Jian [1 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Cardiovasc Surg, Xian, Peoples R China
[2] Air Force Med Univ, Xijing Hosp, Dept Ultrasound Med, Xian, Peoples R China
[3] Naval Mil Med Univ, Changhai Hosp, Dept Cardiovasc Surg, Shanghai, Peoples R China
来源
基金
国家重点研发计划;
关键词
tricuspid regurgitation; transcatheter tricuspid valve replacement; 3-Dimensional printing; LuX-Valve; permanent pacemaker implantation; 1ST-IN-MAN EXPERIENCE; OUTCOMES; REPAIR; INTERVENTIONS; LOCATION; PATIENT; SYSTEM;
D O I
10.3389/fcvm.2023.1030997
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundLead-induced tricuspid regurgitation is one of the complications after permanent pacemaker implantation (PPI) and refers to tricuspid regurgitation (TR) caused by the lead in the right ventricle (RV).ObjectivesTo study the clinical characteristics of severe TR after PPI and the effect of transcatheter tricuspid valve replacement (TTVR) with the guidance of 3-dimensional (3D) printing.MethodsThis study was a single-center, descriptive study. Six patients with severe TR after PPI were enrolled in Xijing Hospital from January 2020 to May 2020. Before TTVR, the 3D printed tricuspid valve (TV) model was used for evaluation in the bench test. LuX-Valve was implanted under the guidance of TEE and x-ray fluoroscopy, and all patients underwent transatrial access. Six patients' data were collected at baseline, before discharge, and 6 months, 1 year and 2 years after TTVR.ResultsThe LuX-Valve was successfully implanted in 6 patients, TR was significantly reduced to <= 2+, and no deaths or cardiopulmonary bypass occurred during procedures. Three cases were caused by TV expansion: Patient #4 had TR caused by lead adhesion to TV, Patient #2 had TR caused by lead winding, and Patient #6 had TR caused by lead impingement on TV. During the 2-year follow-up, TTE revealed that 5 patients had no/trace regurgitation, and one patient (Patient #5) had mild regurgitation. All 6 patients (100.0%) reached primary endpoints.ConclusionTTVR guided by 3D printing is safe and effective in the treatment of severe TR associated with permanent pacemaker lead, providing prospects and possibilities for the precise treatment of TV-related diseases.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker leads: Fact or fiction?
    Lin, G
    Nishimura, R
    Connolly, H
    Dearani, J
    Sundt, T
    Hayes, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 362A - 362A
  • [32] Tricuspid Valve Replacement Preserving Endocardial Pacemaker Lead
    Yoshikai, Masaru
    Miho, Takahiro
    Satoh, Hisashi
    Nakanishi, Harumi
    JOURNAL OF CARDIAC SURGERY, 2016, 31 (05) : 311 - 314
  • [33] Tricuspid Edge-to-Edge Repair Versus Tricuspid Valve Replacement for Severe Tricuspid Regurgitation
    Kim, Jihoon
    Lee, Heemoon
    Jung, Ji-Hyun
    Yoo, Jae Suk
    KOREAN CIRCULATION JOURNAL, 2023, 53 (11) : 775 - 786
  • [34] Impact of transcatheter tricuspid valve replacement for tricuspid regurgitation on hepatic, cardiac, and venous structure
    Ning, Xiaoping
    Cao, Jingyi
    Wang, Wei
    Xu, Zhiyun
    Yang, Fan
    Li, Mengxing
    Wang, He
    Li, Ning
    Zhou, Guangwei
    Bai, Yifan
    Cai, Chengliang
    Li, Bailing
    Han, Lin
    Qiao, Fan
    Lu, Fanglin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 372 : 33 - 39
  • [35] Transcatheter Tricuspid Valve Replacement for Tricuspid Regurgitation: A Systematic Review and Meta-analysis
    Bugan, Baris
    Cekirdekci, Elif Ijlal
    Onar, Lutfi Cagatay
    Barcin, Cem
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2022, 26 (07): : 505 - +
  • [36] Treatment of Severe Tricuspid Regurgitation in a High-Risk Patient Using a Novel Transcatheter Tricuspid Valve
    Wang, Shouzheng
    Pan, Xiangbin
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (20) : E275 - E277
  • [37] Severe Tricuspid Stenosis Secondary to Permanent Pacemaker Lead
    Khan, Asif
    Mustafa, Ahmad
    Ling, Joanne
    Lafferty, James
    JOURNAL OF MEDICAL CASES, 2022, 13 (08) : 365 - 368
  • [38] Predictors of Persistent Tricuspid Regurgitation After Transcatheter Aortic Valve Replacement in Patients With Baseline Tricuspid Regurgitation
    Worku, Berhane
    Valovska, Marie-Therese
    Elmously, Adham
    Kampaktsis, Polydoros
    Castillo, Catherine
    Wong, Shing-Chiu
    Salemi, Arash
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (03) : 190 - 199
  • [39] Pacemaker following transcatheter aortic valve replacement and tricuspid regurgitation: A single-center experience
    Nona, Paul
    Coriasso, Nicholas
    Khan, Arfaat
    Singh, Gurjit
    Eng, Marvin H.
    Frisoli, Tiberio
    O'Neill, Brian P.
    Villablanca, Pedro A.
    Lee, James C.
    Jacobsen, Gordon
    O'Neill, William W.
    Wang, Dee Dee
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (09) : 2937 - 2942
  • [40] Tricuspid Valve Repair Versus Replacement for Very Severe Functional Tricuspid Regurgitation
    Kang, Duk-Hyun
    Jang, Jeong Yoon
    Heo, Ran
    Lee, Sahmin
    Song, Jong-Min
    Choi, Kee-Joon
    Song, Jae-Kwan
    Lee, Jae-Won
    Zo, Joo-Hee
    CIRCULATION, 2016, 134