Treatment of severe tricuspid regurgitation induced by permanent pacemaker lead: Transcatheter tricuspid valve replacement with the guidance of 3-dimensional printing

被引:11
|
作者
Mao, Yu [1 ]
Liu, Yang [1 ]
Meng, Xin [2 ]
Ma, Yanyan [1 ]
Li, Lanlan [1 ]
Zhai, Mengen [1 ]
Jin, Ping [1 ]
Lu, Fanglin [3 ]
Yang, Jian [1 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Cardiovasc Surg, Xian, Peoples R China
[2] Air Force Med Univ, Xijing Hosp, Dept Ultrasound Med, Xian, Peoples R China
[3] Naval Mil Med Univ, Changhai Hosp, Dept Cardiovasc Surg, Shanghai, Peoples R China
来源
基金
国家重点研发计划;
关键词
tricuspid regurgitation; transcatheter tricuspid valve replacement; 3-Dimensional printing; LuX-Valve; permanent pacemaker implantation; 1ST-IN-MAN EXPERIENCE; OUTCOMES; REPAIR; INTERVENTIONS; LOCATION; PATIENT; SYSTEM;
D O I
10.3389/fcvm.2023.1030997
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundLead-induced tricuspid regurgitation is one of the complications after permanent pacemaker implantation (PPI) and refers to tricuspid regurgitation (TR) caused by the lead in the right ventricle (RV).ObjectivesTo study the clinical characteristics of severe TR after PPI and the effect of transcatheter tricuspid valve replacement (TTVR) with the guidance of 3-dimensional (3D) printing.MethodsThis study was a single-center, descriptive study. Six patients with severe TR after PPI were enrolled in Xijing Hospital from January 2020 to May 2020. Before TTVR, the 3D printed tricuspid valve (TV) model was used for evaluation in the bench test. LuX-Valve was implanted under the guidance of TEE and x-ray fluoroscopy, and all patients underwent transatrial access. Six patients' data were collected at baseline, before discharge, and 6 months, 1 year and 2 years after TTVR.ResultsThe LuX-Valve was successfully implanted in 6 patients, TR was significantly reduced to <= 2+, and no deaths or cardiopulmonary bypass occurred during procedures. Three cases were caused by TV expansion: Patient #4 had TR caused by lead adhesion to TV, Patient #2 had TR caused by lead winding, and Patient #6 had TR caused by lead impingement on TV. During the 2-year follow-up, TTE revealed that 5 patients had no/trace regurgitation, and one patient (Patient #5) had mild regurgitation. All 6 patients (100.0%) reached primary endpoints.ConclusionTTVR guided by 3D printing is safe and effective in the treatment of severe TR associated with permanent pacemaker lead, providing prospects and possibilities for the precise treatment of TV-related diseases.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Percutaneous establishment of tricuspid regurgitation: an experimental model for transcatheter tricuspid valve replacement
    Bai Yuan
    Chen Hai-yan
    Zong Gang-jun
    Jiang Hai-bing
    Li Wei-ping
    Wu Hong
    Zhao Xian-xian
    Qin Yong-wen
    CHINESE MEDICAL JOURNAL, 2010, 123 (07) : 806 - 809
  • [22] New therapeutic approach for tricuspid regurgitation: Transcatheter tricuspid valve replacement or repair
    Blusztein, David I.
    Hahn, Rebecca T.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [23] Transjugular Transcatheter Tricuspid Valve Replacement for Original Valve Regurgitation
    Kang, Zhefeng
    Shi, Jun
    Liu, Lulu
    Guo, Yingqiang
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (22) : 2339 - 2340
  • [24] Transcatheter tricuspid valve repair and replacement: a landscape review of current techniques and devices for the treatment of tricuspid valve regurgitation
    Rahgozar, Kusha
    Ho, Edwin
    Goldberg, Ythan
    Chau, Mei
    Latib, Azeem
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2021, 19 (05) : 399 - 411
  • [25] Tricuspid Valve Replacement vs. Repair in Severe Tricuspid Regurgitation
    Chang, Hyoung Woo
    Jeong, Dong Seop
    Cho, Yang Hyun
    Sung, Kiick
    Kim, Wook Sung
    Lee, Young Tak
    Park, Pyo Won
    CIRCULATION JOURNAL, 2017, 81 (03) : 330 - 338
  • [26] Severe tricuspid regurgitation caused by pacemaker lead interference
    Rydlewska, Anna
    Malecka, Barbara
    Zabek, Andrzej
    Hardzina, Malgorzata
    Lelakowski, Jacek
    KARDIOLOGIA POLSKA, 2014, 72 (07) : 659 - 659
  • [27] TRANSCATHETER CAVAL VALVE IMPLANTATION FOR SEVERE TRICUSPID REGURGITATION
    Campos, Enrique Padilla
    Hachey, Brian
    Hurley, Scott
    Mehta, Rohan
    Shahrrava, Anahita
    Tahir, Ammar
    Bazavan, Mugurel
    Collado, Fareed
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2277 - 2277
  • [28] Comprehensive Dynamic 3-Dimensional Analysis of the Tricuspid Valve in Functional Tricuspid Regurgitation: Implications for Prophylactic Tricuspid Valve Intervention
    Sehgal, Sankalp
    Liu, Shou
    Mahmood, Feroze
    Maslow, Andrew
    Ahmed, Andaleeb A.
    Knio, Ziyad O.
    Matyal, Robina
    Chu, Louis
    Liu, David C.
    Senthilnathan, Venkatachalam
    Khabbaz, Kamal R.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2025, 39 (01) : 49 - 60
  • [29] Transcatheter tricuspid valve repair/replacement should be offered to all patients with severe tricuspid regurgitation: pros and cons
    Latib, Azeem
    Mangieri, Antonio
    Nettersheim, Felix Sebastian
    Baldus, Stephan
    EUROINTERVENTION, 2023, 18 (17) : 1395 - 1397
  • [30] Comparing outcomes of transcatheter tricuspid valve replacement and medical therapy for symptomatic severe tricuspid regurgitation: a retrospective study
    Wang, Yiwei
    Liu, Yang
    Meng, Xin
    Zhai, Mengen
    Jin, Ping
    Lu, Fanglin
    Yang, Jian
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2024, 29 (01)