High throughput LC/ESI-MS/MS method for simultaneous analysis of 20 oral molecular-targeted anticancer drugs and the active metabolite of sunitinib in human plasma

被引:1
|
作者
Hirasawa, Tensei [1 ]
Kikuchi, Masafumi [1 ,2 ]
Takasaki, Shinya [2 ]
Kumondai, Masaki [2 ]
Sato, Yu [2 ]
Sato, Toshihiro [2 ]
Imoto, Eishi [3 ]
Hayakawa, Yoshihiro [3 ]
Maekawa, Masamitsu [1 ,2 ]
Mano, Nariyasu [1 ,2 ]
机构
[1] Tohoku Univ, Fac Pharmaceut Sci, 6-3 Aoba,Aoba Ku, Sendai 9808578, Japan
[2] Tohoku Univ Hosp, Dept Pharmaceut Sci, 1-1 Seiryo Machi,Aoba Ku, Sendai 9808574, Japan
[3] Shimadzu Co Ltd, 1 Nishinokyo Kuwabara Cho,Nakagyo Ku, Kyoto 6048511, Japan
关键词
Oral molecular-targeted drug; LC; ESI-MS; MS; Collision energy defects; In-source collision-induced dissociation; Secondary product ion selected reaction; monitoring; Isotopologue selected reaction monitoring; CELL LUNG-CANCER; TYROSINE KINASE INHIBITORS; LINEAR DYNAMIC-RANGE; MASS-SPECTROMETRY; PHARMACOKINETICS; OSIMERTINIB; ERLOTINIB; IMATINIB; CRIZOTINIB; AFATINIB;
D O I
10.1016/j.heliyon.2023.e16926
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Many types of oral molecular-targeted anticancer drugs are clinically used in cancer genomic medicine. Combinations of multiple molecular-targeted anticancer drugs are also being investigated, expecting to prolong the survival of patients with cancer. Therapeutic drug monitoring of oral molecular-targeted drugs is important to ensure efficacy and safety. A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been used for simultaneous determination of these drugs in human plasma. However, the sensitivity of mass spectrometers and differences in the therapeutic range of drugs have rendered the development of simultaneous LC/ESI-MS/MS methods difficult. In this study, a simultaneous quantitative method for 20 oral molecular-targeted anticancer drugs and the active metabolite of sunitinib was developed based on the results of linear range shifts of the calibration curves using four ion abundance adjustment techniques (collision energy defects, in-source collision-induced dissociation, secondary product ion selected reaction monitoring, and isotopologue selected reaction monitoring). The saturation of the detector for the seven analytes was resolved by incorporating optimal ion abundance adjustment techniques. Furthermore, the reproducibility of this method was confirmed in validation tests, and plasma from patients was measured by this method to demonstrate its usefulness in actual clinical practice. This analytical method is expected to make a substantial contribution to the promotion of personalized medicine in the future.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] LC/ESI-MS method for the determination of trimetazidine in human plasma: Application to a bioequivalence study on Chinese volunteers
    Jiao, Yang
    Su, Mingming
    Chen, Minjun
    Jia, Wei
    Chou, Yiqun
    Huang, Zhongyi
    Yang, Nanlin
    Tong, Weida
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1804 - 1807
  • [32] Simultaneous analysis of anticancer agents bortezomib, imatinib, nilotinib, dasatinib, erlotinib, lapatinib, sorafenib, sunitinib and vandetanib in human plasma using LC/MS/MS
    Andriamanana, Irina
    Gana, Ines
    Duretz, Benedicte
    Hulin, Anne
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 926 : 83 - 91
  • [33] Quick and Sensitive UPLC-ESI-MS/MS Method for Simultaneous Estimation of Sofosbuvir and Its Metabolite in Human Plasma
    Semreen, Mohammad H.
    Alniss, Hasan Y.
    Mousa, Muath K.
    Aboul-Enein, Hassan Y.
    MOLECULES, 2019, 24 (07)
  • [34] Direct infusion ESI-MS analysis for metabolite profiling of human plasma using various fractionation techniques
    Musharraf, Syed Ghulam
    Siddiqui, Amna Jabbar
    Mazhar, Shumaila
    BIOANALYSIS, 2014, 6 (15) : 2057 - 2070
  • [35] Simultaneous LC-MS-MS determination of zolmitriptan and its active metabolite N-desmethylzolmitriptan in human plasma
    Kilic, B.
    Oezden, T.
    Toptan, S.
    Oezilhan, S.
    CHROMATOGRAPHIA, 2007, 66 (Suppl 1) : S129 - S133
  • [36] Simultaneous Determination of Orelabrutinib, Zanubrutinib, Ibrutinib and Its Active Metabolite in Human Plasma Using LC-MS/MS
    Sun, Lu-Ning
    Zhao, Yang
    Qian, Zhou-Yi
    Chen, Xiang-Long
    Ma, Hong
    Guo, Yu-Jiao
    Shen, Hao
    Wang, Yong-Qing
    MOLECULES, 2023, 28 (03):
  • [37] Simultaneous determination of subutinib and its active metabolite in human plasma by LC-MS/MS: Application to pharmacokinetic study
    Ding Li-kun
    Yang Lin
    Chen Su-ning
    Li Jian-kang
    Wen Ai-dong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1001 : 22 - 26
  • [38] Determination of the active metabolite of moguisteine in human plasma and urine by LC-ESI-MS method and its application in pharmacokinetic study
    Teng, Yanni
    Song, Haibo
    Bu, Fanlong
    Wei, Chunmin
    Zhao, Wenjing
    Zhang, Rui
    Yuan, Guiyan
    Liu, Xiaoyan
    Wang, Benjie
    Guo, Ruichen
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 31 - 35
  • [39] Liquid chromatography electrospray ionization tandem mass spectrometry(LC/ESI-MS/MS) method for quantitative estimation of moxifloxacin in human plasma
    Vipul.M.Vaghela
    Prajesh Prajapati
    Hetal K.Patel
    Journal of Chinese Pharmaceutical Sciences, 2014, 23 (03) : 159 - 164
  • [40] LC-MS/MS method for a high throughput quantitative analysis of immunosuppressant drugs in whole blood
    Kozak, M.
    Ruzicka, R.
    Bodepudi, V.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A251 - A251