High throughput LC/ESI-MS/MS method for simultaneous analysis of 20 oral molecular-targeted anticancer drugs and the active metabolite of sunitinib in human plasma

被引:1
|
作者
Hirasawa, Tensei [1 ]
Kikuchi, Masafumi [1 ,2 ]
Takasaki, Shinya [2 ]
Kumondai, Masaki [2 ]
Sato, Yu [2 ]
Sato, Toshihiro [2 ]
Imoto, Eishi [3 ]
Hayakawa, Yoshihiro [3 ]
Maekawa, Masamitsu [1 ,2 ]
Mano, Nariyasu [1 ,2 ]
机构
[1] Tohoku Univ, Fac Pharmaceut Sci, 6-3 Aoba,Aoba Ku, Sendai 9808578, Japan
[2] Tohoku Univ Hosp, Dept Pharmaceut Sci, 1-1 Seiryo Machi,Aoba Ku, Sendai 9808574, Japan
[3] Shimadzu Co Ltd, 1 Nishinokyo Kuwabara Cho,Nakagyo Ku, Kyoto 6048511, Japan
关键词
Oral molecular-targeted drug; LC; ESI-MS; MS; Collision energy defects; In-source collision-induced dissociation; Secondary product ion selected reaction; monitoring; Isotopologue selected reaction monitoring; CELL LUNG-CANCER; TYROSINE KINASE INHIBITORS; LINEAR DYNAMIC-RANGE; MASS-SPECTROMETRY; PHARMACOKINETICS; OSIMERTINIB; ERLOTINIB; IMATINIB; CRIZOTINIB; AFATINIB;
D O I
10.1016/j.heliyon.2023.e16926
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Many types of oral molecular-targeted anticancer drugs are clinically used in cancer genomic medicine. Combinations of multiple molecular-targeted anticancer drugs are also being investigated, expecting to prolong the survival of patients with cancer. Therapeutic drug monitoring of oral molecular-targeted drugs is important to ensure efficacy and safety. A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has been used for simultaneous determination of these drugs in human plasma. However, the sensitivity of mass spectrometers and differences in the therapeutic range of drugs have rendered the development of simultaneous LC/ESI-MS/MS methods difficult. In this study, a simultaneous quantitative method for 20 oral molecular-targeted anticancer drugs and the active metabolite of sunitinib was developed based on the results of linear range shifts of the calibration curves using four ion abundance adjustment techniques (collision energy defects, in-source collision-induced dissociation, secondary product ion selected reaction monitoring, and isotopologue selected reaction monitoring). The saturation of the detector for the seven analytes was resolved by incorporating optimal ion abundance adjustment techniques. Furthermore, the reproducibility of this method was confirmed in validation tests, and plasma from patients was measured by this method to demonstrate its usefulness in actual clinical practice. This analytical method is expected to make a substantial contribution to the promotion of personalized medicine in the future.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] An LC-MS/MS method for simultaneous determination of LB-100 and its active metabolite, endothall, in human plasma
    Feng, Ye
    Massarelli, Erminia
    Forman, Eric
    Kovach, John S.
    Salgia, Ravi
    Synold, Timothy W.
    BIOANALYSIS, 2023, 15 (17) : 1095 - 1107
  • [22] A high-throughput LC-MS/MS method for simultaneous determination of isoniazid, ethambutol and pyrazinamide in human plasma
    Prso, Kristian
    Zidekova, Nela
    Porvaznik, Igor
    Solovic, Ivan
    Mokry, Juraj
    Kertys, Martin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (02)
  • [23] Simultaneous analysis of losartan, its active metabolite, and hydrochlorothiazide in human plasma by a UPLC-MS/MS method
    Shah, Priyanka A.
    Sharma, Primal
    Shaw, Jaivik V.
    Sanyal, Mallika
    Shrivastav, Pranav S.
    TURKISH JOURNAL OF CHEMISTRY, 2015, 39 (04) : 714 - 733
  • [24] Simultaneous identification and quantification of oral hypoglycaemic drugs in human plasma using LC-MS/MS
    Binz, T.
    Villani, N.
    Neels, H.
    Wimmer, K.
    Schneider, S.
    THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 482 - 482
  • [25] Simultaneous Determination of Ebastine and Its Active Metabolite (Carebastine) in Human Plasma Using LC-MS-MS
    Feng, Sheng
    Jiang, Ji
    Wang, Peng
    Liu, Dongyang
    Hu, Pei
    CHROMATOGRAPHIA, 2009, 70 (9-10) : 1417 - 1422
  • [26] Simultaneous LC–MS–MS Determination of Zolmitriptan and Its Active Metabolite N-Desmethylzolmitriptan in Human Plasma
    B. Kılıç
    T. Özden
    S. Toptan
    S. Özilhan
    Chromatographia, 2007, 66 : 129 - 133
  • [27] Alternative LC-MS-MS Method for Simultaneous Determination of Proguanil, Its Active Metabolite in Human Plasma and Application to a Bioequivalence Study
    Pingale, Satish G.
    Nerurkar, Ketan K.
    Padgaonkar, Ajit M.
    Pawar, Uttam D.
    Mangaonkar, Kiran V.
    CHROMATOGRAPHIA, 2009, 70 (7-8) : 1095 - 1102
  • [28] Validated Chiral LC-ESI-MS/MS Method for the Simultaneous Quantification of Darolutamide Diastereomers and Its Active Metabolite in Mice Plasma: Application to a Pharmacokinetic Study
    Balaji, Narayan
    Sulochana, Suresh P.
    Saini, Neeraj Kumar
    Kumar, Siva A.
    Mullangi, Ramesh
    DRUG RESEARCH, 2018, 68 (11) : 615 - 624
  • [29] Automated 96-well SPE and LC-MS-MS using ESI for simultaneous determination of artemether and its active metabolite dihydroartemisinin in human plasma
    Oroskar, Asha
    Oroskar, Anil
    Parikh, Saurabh
    Thakkar, Nirav
    Gulati, Ved Bhusan
    LC GC NORTH AMERICA, 2006, : 20 - 20
  • [30] Simultaneous quantitative and qualitative analysis of aliskiren, enalapril and its active metabolite enalaprilat in undiluted human urine utilizing LC-ESI-MS/MS
    Burckhardt, Bjoern B.
    Tins, Jutta
    Laeer, Stephanie
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (12) : 1679 - 1691