Sedation/agitation monitoring using a wearable device for ventilated children

被引:1
|
作者
Isaka, Kanako [1 ]
Hatachi, Takeshi [1 ,2 ]
Morita, Kanako [1 ]
Shimizu, Yoshiyuki [1 ]
Takeuchi, Muneyuki [1 ]
机构
[1] Osaka Womens & Childrens Hosp, Dept Intens Care Med, Izumi, Japan
[2] Osaka Womens & Childrens Hosp, Dept Intens Care Med, 840 Murodocho, Izumi, Osaka 5941101, Japan
关键词
actigraphy; deep sedation; pediatrics; physiologic monitoring; wearable electronic device; SEDATION; DELIRIUM; PROTOCOL; INFANTS; SLEEP;
D O I
10.1111/ped.15660
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Developing continuous and labor-saving sedation/agitation monitoring methods in ventilated children is important to avoid undesirable events such as unplanned extubation. The existing scales are often challenging to use. We therefore aimed to evaluate the feasibility of sedation/agitation monitoring using a wearable device with a built-in accelerometer for ventilated children.Methods: This prospective observational pilot study included children aged 15 years or less, admitted to the pediatric intensive care unit on mechanical ventilation after cardiac catheterization between December 2021 and April 2022. The wearable device with a built-in accelerometer was attached to either of the upper limbs, and accelerations due to upper limb movements were measured for 2 h after admission or until extubation, whichever was earliest. Accelerations were measured at 0.02 s intervals, with the mean acceleration calculated for each 1 min interval. The State Behavioral Scale (SBS) was completed at 1 min intervals, with the SBS score (-1, 0, 1, or 2) compared with the mean acceleration.Results: The study included 20 children with a median age of 12 months. The mean accelerations and SBS scores were positively correlated (Kendall's tau, 0.22; p < 0.001), with an increase in the median (interquartile range) acceleration from an SBS score of -1 through 2, as follows: SBS -1, 0.200 (0.151-0.232) m/s(2); SBS 0, 0.202 (0.190-0.235) m/s(2); SBS, 1, 0.312 (0.236-0.427) m/s(2); SBS 2, 0.455 (0.332-0.517) m/s(2). No adverse events were observed.Conclusions: This study showed that continuous, labor-saving sedation/agitation monitoring of ventilated children was feasible using a wearable device with a built-in accelerometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Monitoring sedation for bronchoscopy in mechanically ventilated patients by using the Ramsay sedation scale versus auditory-evoked potentials
    Hsu, Chien-Wei
    Sun, Shu-Fen
    Chu, Kuo-An
    Lee, David Lin
    Wong, Kam-Fai
    BMC PULMONARY MEDICINE, 2014, 14
  • [22] AUTOMATIC NIGHTTIME AGITATION AND SLEEP DISRUPTION DETECTION USING A WEARABLE ANKLE DEVICE AND MACHINE LEARNING
    Kumar, R.
    Feltch, C.
    Richards, K.
    Morrison, J.
    Rangel, A.
    Janney, R.
    Shayesteh, S.
    Allen, R.
    Banerjee, N.
    SLEEP, 2020, 43 : A168 - A168
  • [23] Monitoring sedation for bronchoscopy in mechanically ventilated patients by using the Ramsay sedation scale versus auditory-evoked potentials
    Chien-Wei Hsu
    Shu-Fen Sun
    Kuo-An Chu
    David Lin Lee
    Kam-Fai Wong
    BMC Pulmonary Medicine, 14
  • [24] Validity of the Modified Richmond Agitation-Sedation Scale for Use in Sedated, Mechanically Ventilated Swine
    Leyden, Katrina N.
    Hanneman, Sandra K.
    JOURNAL OF THE AMERICAN ASSOCIATION FOR LABORATORY ANIMAL SCIENCE, 2012, 51 (01): : 63 - 68
  • [25] Assessment of sedation level in critically ill mechanically ventilated patients: Is bispectral index correlated with Richmond agitation-sedation scale?
    Hashemi, Seyed Jalal
    Soltani, Hassanali
    Taakoob, Reyhanak
    Soleymani, Bahram
    Zeraatkari, Khadije
    Shahin, Samireh
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2008, 13 (04): : 181 - 185
  • [26] Perceptions of a Wearable Ubiquitous Monitoring Device
    Moran, Stuart
    Nishida, Toyoaki
    Nakata, Keiichi
    IEEE TECHNOLOGY AND SOCIETY MAGAZINE, 2013, 32 (03) : 56 - 64
  • [27] WEARABLE MUSCLE TRAINING AND MONITORING DEVICE
    Takei, Yusuke
    Yoshida, Manabu
    Takeshita, Toshihiro
    Kobayashi, Takeshi
    2018 IEEE MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2018, : 55 - 58
  • [28] Design of Wearable Health Monitoring Device
    Devara, Kresna
    Ramadhanty, Savira
    Abuzairi, Tomy
    2ND BIOMEDICAL ENGINEERINGS RECENT PROGRESS IN BIOMATERIALS, DRUGS DEVELOPMENT, AND MEDICAL DEVICES, 2018, 1933
  • [29] A wearable ultrasonic bladder monitoring device
    Kiczek, Bartlomiej
    Golabek, Michal
    Wojcik, Dariusz
    Kania, Konrad
    Kozlowski, Edward
    Rymarczyk, Tomasz
    Sikora, Jan
    PROCEEDINGS OF THE 2022 THE 28TH ANNUAL INTERNATIONAL CONFERENCE ON MOBILE COMPUTING AND NETWORKING, ACM MOBICOM 2022, 2022, : 886 - 888
  • [30] Implementation of a Wearable Cardiorespiratory Monitoring Device
    Vishwaracharya, Megha
    Mohan, Rajasekar
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 344 - 349