Sedation/agitation monitoring using a wearable device for ventilated children

被引:1
|
作者
Isaka, Kanako [1 ]
Hatachi, Takeshi [1 ,2 ]
Morita, Kanako [1 ]
Shimizu, Yoshiyuki [1 ]
Takeuchi, Muneyuki [1 ]
机构
[1] Osaka Womens & Childrens Hosp, Dept Intens Care Med, Izumi, Japan
[2] Osaka Womens & Childrens Hosp, Dept Intens Care Med, 840 Murodocho, Izumi, Osaka 5941101, Japan
关键词
actigraphy; deep sedation; pediatrics; physiologic monitoring; wearable electronic device; SEDATION; DELIRIUM; PROTOCOL; INFANTS; SLEEP;
D O I
10.1111/ped.15660
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background: Developing continuous and labor-saving sedation/agitation monitoring methods in ventilated children is important to avoid undesirable events such as unplanned extubation. The existing scales are often challenging to use. We therefore aimed to evaluate the feasibility of sedation/agitation monitoring using a wearable device with a built-in accelerometer for ventilated children.Methods: This prospective observational pilot study included children aged 15 years or less, admitted to the pediatric intensive care unit on mechanical ventilation after cardiac catheterization between December 2021 and April 2022. The wearable device with a built-in accelerometer was attached to either of the upper limbs, and accelerations due to upper limb movements were measured for 2 h after admission or until extubation, whichever was earliest. Accelerations were measured at 0.02 s intervals, with the mean acceleration calculated for each 1 min interval. The State Behavioral Scale (SBS) was completed at 1 min intervals, with the SBS score (-1, 0, 1, or 2) compared with the mean acceleration.Results: The study included 20 children with a median age of 12 months. The mean accelerations and SBS scores were positively correlated (Kendall's tau, 0.22; p < 0.001), with an increase in the median (interquartile range) acceleration from an SBS score of -1 through 2, as follows: SBS -1, 0.200 (0.151-0.232) m/s(2); SBS 0, 0.202 (0.190-0.235) m/s(2); SBS, 1, 0.312 (0.236-0.427) m/s(2); SBS 2, 0.455 (0.332-0.517) m/s(2). No adverse events were observed.Conclusions: This study showed that continuous, labor-saving sedation/agitation monitoring of ventilated children was feasible using a wearable device with a built-in accelerometer.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] SEDATION-AGITATION SCALE AND BISPECTRAL INDEX TO MONITOR SEDATION DEPTH IN MECHANICALLY VENTILATED
    Ou, Xiaofeng
    Hua, Yusi
    Zhang, Wei
    Zheng, Ruiqiang
    Lin, Hua
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [2] Monitoring of sedation in mechanically ventilated patients using remote technology
    Hanidziar, Dusan
    Westover, Michael Brandon
    CURRENT OPINION IN CRITICAL CARE, 2022, 28 (03) : 360 - 366
  • [3] SMART WEARABLE STRESS MONITORING DEVICE FOR AUTISTIC CHILDREN
    Airij, Awais Gul
    Bakhteri, Rabia
    Khalil-Hani, Mohd
    JURNAL TEKNOLOGI, 2016, 78 (7-5): : 75 - 81
  • [4] Evaluating and Monitoring Sedation, Arousal, and Agitation in the ICU
    Sessler, Curtis N.
    Riker, Richard R.
    Ramsay, Michael A.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 34 (02) : 169 - 178
  • [5] PILOT-STUDY FOR THE DEVELOPMENT OF A MONITORING DEVICE FOR VENTILATED CHILDREN
    WENSLEY, DF
    NOONAN, P
    SEEAR, MD
    WERNER, H
    PIRIE, GE
    PEDIATRIC PULMONOLOGY, 1991, 11 (03) : 272 - 279
  • [6] Wearable Monitoring for the Detection of Nocturnal Agitation in Dementia
    Cristina Marcen, Ana
    Carro, Jesus
    Monasterio, Violeta
    PECCS: PROCEEDINGS OF THE 6TH INTERNATIONAL JOINT CONFERENCE ON PERVASIVE AND EMBEDDED COMPUTING AND COMMUNICATION SYSTEMS, 2016, : 63 - 69
  • [7] Agitation During Procedural Sedation and Analgesia in Children
    Lightdale, Jenifer R.
    Valim, Clarissa
    Mahoney, Lisa B.
    Wong, Sharon
    DiNardo, James
    Goldmann, Donald A.
    CLINICAL PEDIATRICS, 2010, 49 (01) : 35 - 42
  • [8] OUTCOMES OF AN ICU PAIN, AGITATION, SEDATION PROTOCOL IN ONCOLOGY MECHANICALLY VENTILATED PATIENTS
    Patel, Trisha
    Bullick, Dana
    Barniak, Sharon
    Fulcher, Sarah
    Grigsby, Meredith
    Howarth, Dean
    McGovern, Joanne
    Hoag, Jeffrey
    CRITICAL CARE MEDICINE, 2016, 44 (12)
  • [9] Evaluation of Richmond Agitation Sedation Scale (RASS) in Mechanically Ventilated in the Emergency Department
    Pop, Marianne K.
    Dervay, Katelyn R.
    Dansby, Mary
    Jones, Carolina
    ADVANCED EMERGENCY NURSING JOURNAL, 2018, 40 (02) : 131 - 137
  • [10] Locating and Monitoring Emergency Responder using a Wearable Device
    Kunnath, Abishek Thekkeyil
    Pradeep, Preeja
    Ramesh, Maneesha Vinodini