A predicted three-dimensional dose sequence based treatment planning optimization method for gynecologic IMRT

被引:1
|
作者
Jia, Qiyuan [1 ,2 ]
Zheng, Chuancheng [1 ]
Li, Yongbao [3 ]
Guo, Futong [2 ]
Zhou, Linghong [2 ]
Song, Ting [2 ]
机构
[1] Ningbo 2 Hosp, Dept Radiotherapy Technol, Ningbo 315310, Zhejiang, Peoples R China
[2] Southern Med Univ, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Collaborat Innovat Ctr Canc Med, Dept Radiat Oncol, State Key Lab Oncol South China,Canc Ctr, Guangzhou 510060, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
3D dose distribution prediction; Dose sequence-based optimization objective; Knowledge-based treatment planning; optimization; Intensity-modulated radiation therapy; THERAPY;
D O I
10.1016/j.medengphy.2023.104011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In knowledge-based treatment planning (KBTP) for intensity-modulated radiation therapy (IMRT), the quality of the plan is dependent on the sophistication of the predicted dosimetric information and its application. In this paper, we propose a KBTP method that based on the effective and reasonable utilization of a three-dimensional (3D) dose prediction on planning optimization. We used an organs-at-risk (OARs) dose distribution prediction model to create a voxel-based dose sequence based optimization objective for OARs doses. This objective was used to reformulate a traditional fluence map optimization model, which involves a tolerable spatial reassignment of the predicted dose distribution to the OAR voxels based on their current doses' positions at a sorted dose sequencing. The feasibility of this method was evaluated with ten gynecology (GYN) cancer IMRT cases by comparing its generated plan quality with the original clinical plan. Results showed feasible plan by proposed method, with comparable planning target volume (PTV) dose coverage and greater dose sparing of the OARs. Among ten GYN cases, the average V30 and V45 of rectum were decreased by 4%& PLUSMN;4% (p = 0.02) and 4% & PLUSMN;3% (p<0.01), respectively. V30 and V45 of bladder were decreased by 8%& PLUSMN;2% (p<0.01) and 3%& PLUSMN;2% (p<0.01), respectively. Our predicted dose sequence-based planning optimization method for GYN IMRT offered a flexible use of predicted 3D doses while ensuring the output plan consistency.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Knowledge-Based Automatic Treatment Planning for Prostate IMRT Using 3-Dimensional Dose Prediction and Threshold-Based Optimization
    Folkerts, M.
    Long, T.
    Radke, R.
    Lu, W.
    Jia, X.
    Gu, X.
    Chen, M.
    Jiang, S.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [32] Presurgical Virtual Three-Dimensional Treatment Planning
    Farronato, Giampietro
    Giannini, Lucia
    Galbiati, Guido
    Mortellaro, Carmen
    Maspero, Cinzia
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (03) : 820 - 823
  • [33] Three-dimensional treatment planning for prosthetic rehabilitation
    Besimo, CE
    Rohner, HP
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2005, 25 (01) : 81 - 87
  • [34] Three-Dimensional Path Planning of UAV Based on Improved Particle Swarm Optimization
    Deng, Lixia
    Chen, Huanyu
    Zhang, Xiaoyiqun
    Liu, Haiying
    MATHEMATICS, 2023, 11 (09)
  • [35] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, X.
    Li, J.
    Wang, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E307 - E307
  • [36] An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy
    Wang, Xianliang
    Wang, Pei
    Tang, Bin
    Kang, Shengwei
    Hou, Qing
    Wu, Zhangwen
    Gou, Chengjun
    Li, Lintao
    Orlandini, Lucia
    Lang, Jinyi
    Li, Jie
    FRONTIERS IN ONCOLOGY, 2020, 10
  • [37] Controlling dose falloff in IMRT treatment planning: the "anchor zone" method
    Zakarian, C
    Deasy, J
    Alaly, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1875 - 1875
  • [38] IMRT verification by three-dimensional dose reconstruction from portal beam measurements
    Partridge, M
    Ebert, M
    Hesse, BM
    MEDICAL PHYSICS, 2002, 29 (08) : 1847 - 1858
  • [39] A method for improving simplified pencil beam dose in IMRT treatment planning
    Riegel, A
    Chen, Y
    Galvin, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1856 - 1856
  • [40] Preliminary study of clinical application on IMRT three-dimensional dose verification-based EPID system
    Huang, Miaoyun
    Huang, David
    Zhang, Jianping
    Chen, Yuangui
    Xu, Benhua
    Chen, Lixin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (04): : 97 - 105