ONOO- Activatable Fluorescent Sulfur Dioxide Donor for a More Accurate Assessment of Cell Ferroptosis

被引:8
|
作者
Liu, Jianfei [1 ]
Li, Zipeng [1 ]
Peng, Shuxin [1 ]
Tang, Jun [2 ]
Zhang, Di [3 ]
Ye, Yong [1 ,4 ]
机构
[1] Zhengzhou Univ, Coll Chem, Phosphorus Chem Engn Res Ctr Henan Prov, Zhengzhou 450001, Peoples R China
[2] Xinxiang Univ, Sch Chem & Mat Engn, Xinxiang 453003, Peoples R China
[3] Henan Acad Agr Sci, Inst Qual & Safety Agroprod, Henan Key Lab Grain Qual & Safety Testing, Zhengzhou 450002, Peoples R China
[4] Zhengzhou Univ, Zhengzhou 450001, Henan, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
PULMONARY-HYPERTENSION; PATHWAYS; RAT;
D O I
10.1021/acs.analchem.3c04565
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ferroptosis is critical in the treatment of tumor therapies. Thus, monitoring reactive oxygen species (ROS) is of great significance for accurate assessment in ferroptosis without any interference. However, current probes for monitoring ROS during ferroptosis suffer from a drawback in that the probes consume ROS during detection, which inhibits the ferroptosis process and thus affects the accuracy and effectiveness of monitoring the process of ferroptosis. Herein, a new fluorescent donor probe, TFMU-SO2D, with the combination of the moiety of the SO2 donor is designed and synthesized by introducing the aryl boronate moieties that could give it the ability to effectively recognize ONOO-. The released SO2 could consume excess glutathione and regulate oxidative stress by elevating ROS levels, which would offset the ROS depletion by TFMU-SO2D and ensure accuracy in monitoring the ferroptosis process. The experimental results demonstrated that TFMU-SO2D possessed satisfactory performance for monitoring ONOO- as well as simultaneously releasing SO2 in oxidative stress stimulated by monensin and ferroptosis stimulated by erastin and RSL3. Additionally, the capability of SO2 synergized with ferroptosis to inhibit the viability of cancer cells was demonstrated by the CCK8 assay, which may be due to the fact that SO2 can potentiate ferroptosis cell death by increasing the ROS level. Overall, these combined results indicated that TFMU-SO2D possesses the excellent ability to precisely monitor ONOO- during ferroptosis without interference, which is significant for accurately accessing ferroptosis, cancer treatment, and drug development.
引用
收藏
页码:2041 / 2051
页数:11
相关论文
共 27 条
  • [21] Rational design of a negative photochromic spiropyran-containing fluorescent polymeric nanoprobe for sulfur dioxide derivative ratiometric detection and cell imaging
    Xiang Li
    Zhong Lin
    Yong Tian
    Chonghua Zhang
    Peisheng Zhang
    Rongjin Zeng
    Lei Qiao
    Jian Chen
    Analytical and Bioanalytical Chemistry, 2023, 415 : 715 - 724
  • [22] Water-soluble improved NIR ratiometric fluorescent probe for specific imaging sulfur dioxide in cancer cell membranes and living mice
    Liu, Tao
    Zhao, Wenjing
    Guo, Zilong
    Zhai, Yunze
    Zhang, Weijie
    Yang, Xufeng
    Chen, Dongdong
    Yin, Caixia
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 368
  • [23] A novel antiviral intervention results in more accurate assessment of human immunodeficiency virus type 1 replication dynamics and T-Cell decay in vivo
    Markowitz, M
    Louie, M
    Hurley, A
    Sun, E
    Di Mascio, M
    JOURNAL OF VIROLOGY, 2003, 77 (08) : 5037 - 5038
  • [24] Morphokinetic assessment using time-lapse imaging allows more accurate identification of embryos with multiple rather than single aneuploidies up to the 8-cell stage
    Davies, S.
    Tsorva, E.
    Christopikou, D.
    Vogiatzi, P.
    Karagianni, A.
    Handyside, A. H.
    Mastrominas, M.
    HUMAN REPRODUCTION, 2014, 29 : 179 - 179
  • [25] Assessment of Donor-Derived Cell-Free DNA for Allograft Rejection in Kidney Transplant Patients More Than 1 Year from Transplant: Implications for Clinical Management
    Morgan, Mike
    McCormick, Sarah
    Gauthier, Philippe
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2021, 32 (10): : 844 - 844
  • [26] Mean cell volume measurement on Sysmex XE series instruments using the RPU-2100 diluent system: how external quality assessment works to provide more accurate MCV results and potentially benefit patient management
    De la Salle, Barbara Joan
    Briggs, Carol
    Bleby, John
    Mellors, Ian
    McTaggart, Paul
    Hyde, Keith
    JOURNAL OF CLINICAL PATHOLOGY, 2013, 66 (05) : 449 - 450
  • [27] The use of cell line standards and external quality assessment to standardise assays for HER-2/neu in European cancer centres and the potential of automated image analysis to provide more accurate cut-points for predicting clinical response to trastuzumab
    Rhodes, A
    Borthwick, D
    Sykes, R
    Paradiso, A
    BREAST CANCER RESEARCH AND TREATMENT, 2003, 82 : S76 - S76