High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS

被引:6
|
作者
Bai, Jiang-Hao [1 ,2 ,4 ]
Lin, Mang [1 ]
Zhong, Song-Xiong [3 ]
Deng, Yi-Nan [2 ]
Zhang, Le [1 ]
Luo, Kai [1 ,4 ]
Wu, Hao [1 ,4 ]
Ma, Jin-Long [1 ]
Wei, Gang-Jian [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, CAS Ctr Excellence Deep Earth Sci, State Key Lab Isotope Geochem, Guangzhou 510640, Peoples R China
[2] Minist Nat & Resources, Key Lab Marine Mineral Resources, Guangzhou 511458, Peoples R China
[3] Guangdong Acad Sci, Inst Ecoenvironm & Soil Sci, Natl Reg Joint Engn Res Ctr Soil Pollut Control &, Key Lab Integrated Agroenvironm Pollut Control & M, Guangzhou 510650, Guangdong, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
RARE-EARTH-ELEMENTS; TODGA RESIN COLUMN; HALF-LIFE; SEPARATION; NEODYMIUM; ND; FRACTIONATION; EXTRACTION; RATIO; EVOLUTION;
D O I
10.1039/d2ja00412g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of Sm isotopes in geological materials is challenging, thus limiting their extensive applications in geoscience and environmental science. Herein, we developed a technique for the high intermediate precision analysis of Sm isotopes via multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). Interference impurities, particularly Nd, Eu, and Gd, were completely removed from Sm using a new two-column [AG50W-X12 (200-400 mesh) and TODGA (50-100 mu m)] procedure, which quantitatively (99.4 +/- 0.3%) extracted Sm. The complete purification of Sm allowed the development of a high intermediate precision calibration method combined with standard-sample bracketing and Eu internal normalization to correct the instrumental mass bias. A long-term intermediate precision better than 0.04 parts per thousand (2SD) for delta Sm-152/149 was obtained. This intermediate precision is significantly better than those of the existing MC-ICP-MS methods (0.15 parts per thousand-0.30 parts per thousand) and double spike-thermal ionization mass spectrometry methods (0.15 parts per thousand-0.20 parts per thousand), as confirmed by multiple purifications and measurements of 11 geological reference materials (GRMs) with different rock types (e.g., basalt, andesite, granodiorite, granite, nepheline, syenite, manganese nodule, and marine sediment). In addition, we observed a detectable variation in delta Sm-152/149 (0.22 parts per thousand) among these 11 GRMs, which could not be identified at the previous intermediate precision. This finding highlights that the high intermediate precision delta Sm-152/149 measurements in natural samples established herein have the potential to provide new constraints on diverse natural processes, ranging from planetary formation to chemical weathering and ocean circulation and create new opportunities for stable Sm isotope studies.
引用
收藏
页码:629 / 637
页数:10
相关论文
共 50 条
  • [31] Accuracy and long-term precision of MC-ICP-MS isotope ratios
    Thirlwall, M
    Ancziewicz, R
    Vance, D
    Munday, D
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A771 - A771
  • [32] Sulfur isotope analysis by MC-ICP-MS and application to small medical samples
    Albalat, Emmanuelle
    Telouk, Philippe
    Balter, Vincent
    Fujii, Toshiyuki
    Bondanese, Victor Packy
    Plissonnier, Marie-Laure
    Vlaeminck-Guillem, Virginie
    Baccheta, Justine
    Thiam, Ndieme
    Miossec, Pierre
    Zoulim, Fabien
    Puisieux, Alain
    Albarede, Francis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (04) : 1002 - 1011
  • [33] Polyatomic interferences on high precision uranium isotope ratio measurements by MC-ICP-MS: applications to environmental sampling for nuclear safeguards
    Anthony D. Pollington
    William S. Kinman
    Susan K. Hanson
    Robert E. Steiner
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 2109 - 2115
  • [34] Polyatomic interferences on high precision uranium isotope ratio measurements by MC-ICP-MS: applications to environmental sampling for nuclear safeguards
    Pollington, Anthony D.
    Kinman, William S.
    Hanson, Susan K.
    Steiner, Robert E.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 2109 - 2115
  • [35] High-Precision Cd Isotope Measurements of Soil and Rock Reference Materials by MC-ICP-MS with Double Spike Correction
    Liu, Meng-Shu
    Zhang, Qun
    Zhang, Yingnan
    Zhang, Zhaofeng
    Huang, Fang
    Yu, Hui-Min
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (01) : 169 - 182
  • [36] Precise Mo isotope ratio measurements of low-Mo (ng g-1) geological samples using MC-ICP-MS
    Liu, Jie
    Wen, Hanjie
    Zhang, Yuxu
    Fan, Haifeng
    Zhu, Chuanwei
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (06) : 1287 - 1297
  • [37] Calcium isotope measurements using a collision cell (CC)-MC-ICP-MS
    Dai, Wei
    Moynier, Frederic
    Paquet, Marine
    Moureau, Julien
    Debret, Baptiste
    Siebert, Julien
    Gerard, Yvan
    Zhao, Ye
    CHEMICAL GEOLOGY, 2022, 590
  • [38] High-precision copper and iron isotope analysis of igneous rock standards by MC-ICP-MS
    Liu, Sheng-Ao
    Li, Dandan
    Li, Shuguang
    Teng, Fang-Zhen
    Ke, Shan
    He, Yongsheng
    Lu, Yinghuai
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (01) : 122 - 133
  • [39] The impact of MC-ICP-MS plasma conditions on the accuracy and precision of stable isotope measurements evaluated for barium isotopes
    Yu, Yang
    Siebert, Christopher
    Fietzke, Jan
    Goepfert, Tyler
    Hathorne, Ed
    Cao, Zhimian
    Frank, Martin
    CHEMICAL GEOLOGY, 2020, 549
  • [40] High-precision Mg isotope analyses of low-Mg rocks by MC-ICP-MS
    An, Yajun
    Wu, Fei
    Xiang, Yuanxin
    Nan, Xiaoyun
    Yu, Xun
    Yang, Jinhui
    Yu, Huimin
    Xie, Liewen
    Huang, Fang
    CHEMICAL GEOLOGY, 2014, 390 : 9 - 21