High intermediate precision Sm isotope measurements in geological samples by MC-ICP-MS

被引:6
|
作者
Bai, Jiang-Hao [1 ,2 ,4 ]
Lin, Mang [1 ]
Zhong, Song-Xiong [3 ]
Deng, Yi-Nan [2 ]
Zhang, Le [1 ]
Luo, Kai [1 ,4 ]
Wu, Hao [1 ,4 ]
Ma, Jin-Long [1 ]
Wei, Gang-Jian [1 ]
机构
[1] Chinese Acad Sci, Guangzhou Inst Geochem, CAS Ctr Excellence Deep Earth Sci, State Key Lab Isotope Geochem, Guangzhou 510640, Peoples R China
[2] Minist Nat & Resources, Key Lab Marine Mineral Resources, Guangzhou 511458, Peoples R China
[3] Guangdong Acad Sci, Inst Ecoenvironm & Soil Sci, Natl Reg Joint Engn Res Ctr Soil Pollut Control &, Key Lab Integrated Agroenvironm Pollut Control & M, Guangzhou 510650, Guangdong, Peoples R China
[4] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
基金
中国国家自然科学基金;
关键词
RARE-EARTH-ELEMENTS; TODGA RESIN COLUMN; HALF-LIFE; SEPARATION; NEODYMIUM; ND; FRACTIONATION; EXTRACTION; RATIO; EVOLUTION;
D O I
10.1039/d2ja00412g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The measurement of Sm isotopes in geological materials is challenging, thus limiting their extensive applications in geoscience and environmental science. Herein, we developed a technique for the high intermediate precision analysis of Sm isotopes via multi-collector-inductively coupled plasma-mass spectrometry (MC-ICP-MS). Interference impurities, particularly Nd, Eu, and Gd, were completely removed from Sm using a new two-column [AG50W-X12 (200-400 mesh) and TODGA (50-100 mu m)] procedure, which quantitatively (99.4 +/- 0.3%) extracted Sm. The complete purification of Sm allowed the development of a high intermediate precision calibration method combined with standard-sample bracketing and Eu internal normalization to correct the instrumental mass bias. A long-term intermediate precision better than 0.04 parts per thousand (2SD) for delta Sm-152/149 was obtained. This intermediate precision is significantly better than those of the existing MC-ICP-MS methods (0.15 parts per thousand-0.30 parts per thousand) and double spike-thermal ionization mass spectrometry methods (0.15 parts per thousand-0.20 parts per thousand), as confirmed by multiple purifications and measurements of 11 geological reference materials (GRMs) with different rock types (e.g., basalt, andesite, granodiorite, granite, nepheline, syenite, manganese nodule, and marine sediment). In addition, we observed a detectable variation in delta Sm-152/149 (0.22 parts per thousand) among these 11 GRMs, which could not be identified at the previous intermediate precision. This finding highlights that the high intermediate precision delta Sm-152/149 measurements in natural samples established herein have the potential to provide new constraints on diverse natural processes, ranging from planetary formation to chemical weathering and ocean circulation and create new opportunities for stable Sm isotope studies.
引用
收藏
页码:629 / 637
页数:10
相关论文
共 50 条
  • [21] Precise determination of the lithium isotope ratio in geological samples using MC-ICP-MS with cool plasma
    Choi, Min Seok
    Ryu, Jong-Sik
    Park, Ha Yan
    Lee, Kwang-Sik
    Kil, Youngwoo
    Shin, Hyung Seon
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2013, 28 (04) : 505 - 509
  • [22] Gd matrix effects on Eu isotope fractionation using MC-ICP-MS: Optimizing europium isotope ratio measurements in geological rock samples
    Lee, Seung-Gu
    Tanaka, Tsuyoshi
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 469
  • [23] Zinc Isotope Measurement by MC-ICP-MS in Geological Certified Reference Materials
    Wang, Jing
    Tang, Dong-Mei
    Yuan, Qing-Han
    Su, Ben-Xun
    Li, Wen-Jun
    Gao, Bing-Yu
    Bao, Zhi-An
    Zhao, Ye
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2023, 47 (04) : 969 - 982
  • [24] Ion exchange chromatography and high precision isotopic measurements of zirconium by MC-ICP-MS
    Schönbächler, M
    Rehkämper, M
    Lee, DC
    Halliday, AN
    ANALYST, 2004, 129 (01) : 32 - 37
  • [25] Cadmium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Ohlander, Bjorn
    Ingri, Johan
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1570 - 1584
  • [26] Chromium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Ponter, Simon
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (07) : 1464 - 1471
  • [27] Analysis of high-precision vanadium isotope ratios by medium resolution MC-ICP-MS
    Nielsen, Sune G.
    Owens, Jeremy D.
    Horner, Tristan J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 531 - 536
  • [28] Precise and accurate determination of Sm, Nd concentrations and Nd isotopic compositions in geological samples by MC-ICP-MS
    Yang, Yue-Heng
    Chu, Zhu-Yin
    Wu, Fu-Yuan
    Xie, Lie-Wen
    Yang, Jin-Hui
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (06) : 1237 - 1244
  • [29] One-step chromatographic purification of K, Ca, and Sr from geological samples for high precision stable and radiogenic isotope analysis by MC-ICP-MS
    Li, Xiaoqiang
    Han, Guilin
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (03) : 676 - 684
  • [30] Vanadium isotope measurement by MC-ICP-MS
    Wu, Fei
    Qi, Yuhan
    Yu, Huimin
    Tian, Shengyu
    Hou, Zhenhui
    Huang, Fang
    CHEMICAL GEOLOGY, 2016, 421 : 17 - 25