Fully automated construction of three-dimensional finite element simulations from Optical Coherence Tomography

被引:9
|
作者
Straughan, Ross [1 ,2 ]
Kadry, Karim [3 ]
Parikh, Sahil A. [4 ]
Edelman, Elazer R. [3 ,5 ]
Nezami, Farhad R. [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Div Cardiac Surg, Boston, MA 02115 USA
[2] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Inst Proc Engn, Leonhardstr 21, CH-8092 Zurich, Switzerland
[3] Inst Med Engn & Sci, MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Columbia Univ, Irving Med Ctr, Div Cardiol, New York, NY 10032 USA
[5] Brigham & Womens Hosp, Harvard Med Sch, Cardiovasc Div, Boston, MA 02115 USA
关键词
Structural mechanics; Atherosclerosis; Optical Coherence Tomography; Three-dimensional reconstruction; Digital twin; WALL SHEAR-STRESS; ATHEROSCLEROTIC PLAQUES; CORONARY; CALCIFICATION; RUPTURE; TISSUE;
D O I
10.1016/j.compbiomed.2023.107341
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite recent advances in diagnosis and treatment, atherosclerotic coronary artery diseases remain a leading cause of death worldwide. Various imaging modalities and metrics can detect lesions and predict patients at risk; however, identifying unstable lesions is still difficult. Current techniques cannot fully capture the complex morphology-modulated mechanical responses that affect plaque stability, leading to catastrophic failure and mute the benefit of device and drug interventions. Finite Element (FE) simulations utilizing intravascular imaging OCT (Optical Coherence Tomography) are effective in defining physiological stress distributions. However, creating 3D FE simulations of coronary arteries from OCT images is challenging to fully automate given OCT frame sparsity, limited material contrast, and restricted penetration depth. To address such limitations, we developed an algorithmic approach to automatically produce 3D FE-ready digital twins from labeled OCT images. The 3D models are anatomically faithful and recapitulate mechanically relevant tissue lesion components, automatically producing morphologies structurally similar to manually constructed models whilst including more minute details. A mesh convergence study highlighted the ability to reach stress and strain convergence with average errors of just 5.9% and 1.6% respectively in comparison to FE models with approximately twice the number of elements in areas of refinement. Such an automated procedure will enable analysis of large clinical cohorts at a previously unattainable scale and opens the possibility for in-silico methods for patient specific diagnoses and treatment planning for coronary artery disease.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Three-dimensional finite element simulations of milling carbon/epoxy composites
    He, Yanli
    Li, Long
    Wan, Min
    Xue, Hongqian
    COMPOSITE STRUCTURES, 2022, 282
  • [42] Three-dimensional live imaging of bovine embryos by optical coherence tomography
    Masuda, Yasumitsu
    Hasebe, Ryo
    Kuromi, Yasushi
    Kobayashi, Masayoshi
    Iwamoto, Misaki
    Hishinuma, Mitsugu
    Ohbayashi, Tetsuya
    Nishimura, Ryo
    JOURNAL OF REPRODUCTION AND DEVELOPMENT, 2021, 67 (02): : 149 - 154
  • [43] Three-dimensional retinal maps with tracking optical coherence tomography (TOCT)
    Ferguson, RD
    Hammer, DX
    Iftimia, NV
    Slaoui, K
    Wollstein, G
    Ishikawa, H
    Gabriele, ML
    Schuman, JS
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 66 - 71
  • [44] Three-dimensional optical coherence tomography: possibilities in assessing the microvasculature of the skin
    Petrova, K. S.
    Nemirova, S., V
    Petrova, G. A.
    Karpenko, A. A.
    Ryabkov, M. G.
    PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2022, 2022, 11934
  • [45] Three-dimensional optical coherence tomography of the embryonic murine cardiovascular system
    Luo, Wei
    Marks, Daniel L.
    Ralston, Tyler S.
    Boppart, Stephen A.
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (02)
  • [46] Single cardiac cycle three-dimensional intracoronary optical coherence tomography
    Kim, Tae Shik
    Park, Hyun-Sang
    Jang, Sun-Joo
    Song, Joon Woo
    Cho, Han Saem
    Kim, Sunwon
    Bouma, Brett E.
    Kim, Jin Won
    Oh, Wang-Yuhl
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 4847 - 4858
  • [47] Optical coherence tomography of cell dynamics in three-dimensional engineered tissues
    Tan, W
    Desai, TA
    Leckband, D
    Boppart, SA
    IMAGING, MANIPULATION, AND ANALYSIS OF BIOMOLECULES AND CELLS: FUNDAMENTALS AND APPLICATIONS III, 2005, 5699 : 102 - 110
  • [48] Multispectral in vivo three-dimensional optical coherence tomography of human skin
    Alex, Aneesh
    Povazay, Boris
    Hofer, Bernd
    Popov, Sergei
    Glittenberg, Carl
    Binder, Susanne
    Drexler, Wolfgang
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
  • [49] Dither Removing of Three-Dimensional Optical Coherence Tomography Retinal Image
    Wang Quan
    Peng Hanlin
    Wang Pinghe
    Fan Jinyu
    Liu Jingxuan
    Shi Guohua
    ACTA OPTICA SINICA, 2019, 39 (03)
  • [50] Three-dimensional image of the human tooth based on optical coherence tomography
    Liang, Y.
    Yao, X.S.
    Lan, S.
    Yao, H.
    Liu, T.
    Wan, M.
    Liang, Y.
    Li, Y.
    Shi, B.
    Wang, G.
    Progress In Electromagnetics Research C, 2009, 8 : 13 - 25