Fully automated construction of three-dimensional finite element simulations from Optical Coherence Tomography

被引:9
|
作者
Straughan, Ross [1 ,2 ]
Kadry, Karim [3 ]
Parikh, Sahil A. [4 ]
Edelman, Elazer R. [3 ,5 ]
Nezami, Farhad R. [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Div Cardiac Surg, Boston, MA 02115 USA
[2] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Inst Proc Engn, Leonhardstr 21, CH-8092 Zurich, Switzerland
[3] Inst Med Engn & Sci, MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Columbia Univ, Irving Med Ctr, Div Cardiol, New York, NY 10032 USA
[5] Brigham & Womens Hosp, Harvard Med Sch, Cardiovasc Div, Boston, MA 02115 USA
关键词
Structural mechanics; Atherosclerosis; Optical Coherence Tomography; Three-dimensional reconstruction; Digital twin; WALL SHEAR-STRESS; ATHEROSCLEROTIC PLAQUES; CORONARY; CALCIFICATION; RUPTURE; TISSUE;
D O I
10.1016/j.compbiomed.2023.107341
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite recent advances in diagnosis and treatment, atherosclerotic coronary artery diseases remain a leading cause of death worldwide. Various imaging modalities and metrics can detect lesions and predict patients at risk; however, identifying unstable lesions is still difficult. Current techniques cannot fully capture the complex morphology-modulated mechanical responses that affect plaque stability, leading to catastrophic failure and mute the benefit of device and drug interventions. Finite Element (FE) simulations utilizing intravascular imaging OCT (Optical Coherence Tomography) are effective in defining physiological stress distributions. However, creating 3D FE simulations of coronary arteries from OCT images is challenging to fully automate given OCT frame sparsity, limited material contrast, and restricted penetration depth. To address such limitations, we developed an algorithmic approach to automatically produce 3D FE-ready digital twins from labeled OCT images. The 3D models are anatomically faithful and recapitulate mechanically relevant tissue lesion components, automatically producing morphologies structurally similar to manually constructed models whilst including more minute details. A mesh convergence study highlighted the ability to reach stress and strain convergence with average errors of just 5.9% and 1.6% respectively in comparison to FE models with approximately twice the number of elements in areas of refinement. Such an automated procedure will enable analysis of large clinical cohorts at a previously unattainable scale and opens the possibility for in-silico methods for patient specific diagnoses and treatment planning for coronary artery disease.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Three-dimensional Imaging of Ureter With Endoscopic Optical Coherence Tomography
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew M.
    UROLOGY, 2011, 77 (05) : 1254 - 1258
  • [22] Three-dimensional optical coherence tomography of granular corneal dystrophy
    Miura, Masahiro
    Mori, Hideki
    Watanabe, Yuji
    Usui, Masahiko
    Kawana, Keisuke
    Oshika, Tetsuro
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    CORNEA, 2007, 26 (03) : 373 - 374
  • [23] Three-dimensional color camera based on optical coherence tomography
    Cen, Zhentao
    Zeng, Kun
    Liu, Biwang
    Huang, Liyuan
    He, Zhennan
    Xiong, Honglian
    Han, Dingan
    Zeng, Yaguang
    OPTICS COMMUNICATIONS, 2021, 478
  • [24] Three-dimensional Reconstruction of Optical Coherence Tomography Images of Esophagus
    Nao, Sihan
    Zhang, Miao
    Wang, Lirong
    Xu, Yongjin
    Chen, Xiaohe
    PROCEEDINGS OF 2019 4TH INTERNATIONAL CONFERENCE ON BIOMEDICAL SIGNAL AND IMAGE PROCESSING (ICBIP 2019), 2019, : 77 - 82
  • [25] THREE-DIMENSIONAL IMAGING OF URETER WITH ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY
    Wang, Hui
    Kang, Wei
    Zhu, Hui
    MacLennan, Gregory
    Rollins, Andrew
    JOURNAL OF UROLOGY, 2011, 185 (04): : E923 - E923
  • [26] Three-dimensional optical coherence tomography of proliferative diabetic retinopathy
    Iwasaki, T.
    Miura, M.
    Matsushima, C.
    Yamanari, M.
    Makita, S.
    Yasuno, Y.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (05) : 713 - 713
  • [27] Three-dimensional imaging of artificial fingerprint by Optical Coherence Tomography
    Larin, Kirill V.
    Cheng, Yezeng
    BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION V, 2008, 6944
  • [28] Video-rate three-dimensional optical coherence tomography
    Laubscher, M
    Ducros, M
    Karamata, B
    Lasser, T
    Salathé, R
    OPTICS EXPRESS, 2002, 10 (09): : 429 - 435
  • [29] Three-dimensional multifunctional optical coherence tomography for skin imaging
    Li, En
    Makita, Shuichi
    Hong, Young-Joo
    Kasaragod, Deepa
    Sasaoka, Tomoko
    Yamanari, Masahiro
    Sugiyama, Satoshi
    Yasuno, Yoshiaki
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS XII, 2016, 9689
  • [30] Optical coherence tomography for the analysis of three-dimensional flow fields
    Böhmer, Michael
    Hinrichs, Heiko
    Hinsch, Klaus D.
    Kickstein, Jan
    Netter, René
    Surmann, Christof
    Optics and Photonics News, 1997, 8 (12): : 19 - 20