Fully automated construction of three-dimensional finite element simulations from Optical Coherence Tomography

被引:9
|
作者
Straughan, Ross [1 ,2 ]
Kadry, Karim [3 ]
Parikh, Sahil A. [4 ]
Edelman, Elazer R. [3 ,5 ]
Nezami, Farhad R. [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Div Cardiac Surg, Boston, MA 02115 USA
[2] Swiss Fed Inst Technol, Dept Mech & Proc Engn, Inst Proc Engn, Leonhardstr 21, CH-8092 Zurich, Switzerland
[3] Inst Med Engn & Sci, MIT, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[4] Columbia Univ, Irving Med Ctr, Div Cardiol, New York, NY 10032 USA
[5] Brigham & Womens Hosp, Harvard Med Sch, Cardiovasc Div, Boston, MA 02115 USA
关键词
Structural mechanics; Atherosclerosis; Optical Coherence Tomography; Three-dimensional reconstruction; Digital twin; WALL SHEAR-STRESS; ATHEROSCLEROTIC PLAQUES; CORONARY; CALCIFICATION; RUPTURE; TISSUE;
D O I
10.1016/j.compbiomed.2023.107341
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Despite recent advances in diagnosis and treatment, atherosclerotic coronary artery diseases remain a leading cause of death worldwide. Various imaging modalities and metrics can detect lesions and predict patients at risk; however, identifying unstable lesions is still difficult. Current techniques cannot fully capture the complex morphology-modulated mechanical responses that affect plaque stability, leading to catastrophic failure and mute the benefit of device and drug interventions. Finite Element (FE) simulations utilizing intravascular imaging OCT (Optical Coherence Tomography) are effective in defining physiological stress distributions. However, creating 3D FE simulations of coronary arteries from OCT images is challenging to fully automate given OCT frame sparsity, limited material contrast, and restricted penetration depth. To address such limitations, we developed an algorithmic approach to automatically produce 3D FE-ready digital twins from labeled OCT images. The 3D models are anatomically faithful and recapitulate mechanically relevant tissue lesion components, automatically producing morphologies structurally similar to manually constructed models whilst including more minute details. A mesh convergence study highlighted the ability to reach stress and strain convergence with average errors of just 5.9% and 1.6% respectively in comparison to FE models with approximately twice the number of elements in areas of refinement. Such an automated procedure will enable analysis of large clinical cohorts at a previously unattainable scale and opens the possibility for in-silico methods for patient specific diagnoses and treatment planning for coronary artery disease.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Automated Three-Dimensional Detection of Intracoronary Stent Struts in Optical Coherence Tomography Images
    Bruining, Nico
    Sihan, Kenji
    Ligthart, Jurgen
    Cummins, Paul
    de Winter, Sebastiaan
    Regar, Evelyn
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B181 - B181
  • [2] Automated Coronary Optical Coherence Tomography Feature Extraction with Application to Three-Dimensional Reconstruction
    Carpenter, Harry J.
    Ghayesh, Mergen H.
    Zander, Anthony C.
    Li, Jiawen
    Di Giovanni, Giuseppe
    Psaltis, Peter J.
    TOMOGRAPHY, 2022, 8 (03) : 1307 - 1349
  • [3] Automated Three-Dimensional Detection of Intracoronary Stent Struts in Optical Coherence Tomography Images
    Bruining, Nico
    Sihan, Kenji
    Ligthart, Jurgen
    de Winter, Sebastiaan
    Regar, Evelyn
    2011 COMPUTING IN CARDIOLOGY, 2011, 38 : 221 - 224
  • [4] A three-dimensional finite element model from computed tomography data: a semi-automated method
    Cattaneo, PM
    Dalstra, M
    Frich, LH
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H2) : 203 - 213
  • [5] Structured three-dimensional optical phantom for optical coherence tomography
    Curatolo, Andrea
    Kennedy, Brendan F.
    Sampson, David D.
    OPTICS EXPRESS, 2011, 19 (20): : 19480 - 19485
  • [6] Three-dimensional finite-element-based photoacoustic tomography: Reconstruction algorithm and simulations
    Yuan, Zhen
    Jiang, Huabei
    MEDICAL PHYSICS, 2007, 34 (02) : 538 - 546
  • [7] Three-dimensional finite element simulations of hydroshield tunneling
    Kasper, T
    Meschke, G
    (RE)CLAIMING THE UNDERGROUND SPACE, VOLS 1 AND 2, PROCEEDINGS, 2003, : 779 - 785
  • [8] Three-dimensional optical coherence tomography of the murine embryo
    Luo, W
    Ralston, T
    Marks, DL
    Boppart, SA
    FASEB JOURNAL, 2005, 19 (04): : A798 - A798
  • [9] Three-dimensional optical coherence tomography for biomedical diagnosis
    Chan, KP
    2005 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, 2005, : 42 - 43
  • [10] Three-dimensional endomicroscopy using optical coherence tomography
    Desmond C. Adler
    Yu Chen
    Robert Huber
    Joseph Schmitt
    James Connolly
    James G. Fujimoto
    Nature Photonics, 2007, 1 : 709 - 716