QUANTITATIVE ANALYSIS OF ELECTRICAL CURRENT EFFECT ON MAGNETIC RESONANCE IMAGE TISSUE INTENSITY

被引:0
|
作者
Ain, Khusnul [1 ]
Choridah, Lina [2 ]
Kurniadi, Deddy [3 ]
Garnadi, Agah D. [4 ]
Mukhaiyar, Utriweni [5 ]
Setyawan, Nurhuda Hendra [2 ]
机构
[1] Biomed Engn Airlangga Univ, Kota, Indonesia
[2] Univ Gadjah Mada, Dept Radiol, Fac Med Publ Hlth & Nursing, Yogyakarta, Indonesia
[3] Bandung Inst Technol, Dept Engn Phys, Bandung, Indonesia
[4] Bogor Agr Inst, Math & Sci, Bogor, Indonesia
[5] Bandung Inst Technol, Fac Math & Nat Sci, Stat Res Div, Bandung, Indonesia
来源
JURNAL TEKNOLOGI-SCIENCES & ENGINEERING | 2023年 / 85卷 / 02期
关键词
Magnetic resonance imaging; Tissue image intensity; T1-weighted image; T2-weighted images; MREIT; IMPEDANCE TOMOGRAPHY MREIT; CONTRAST; MRI; RESOLUTION; TOXICITY; MASS;
D O I
10.11113/jurnalteknologi.v85.18871
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent studies in magnetic resonance imaging (MRI) aim to improve image quality while reducing scan time. Electrical current injection in the form of magnetic resonance electrical impedance tomography (MREIT) is believed to be affecting image quality and scan time thus can improve the possibility of becoming a non-chemical contrast agent in MRI. This study will observe and analyze the effect of electrical current injection on a phantom object to determine whether there is a different tissue image intensity. A thigh of lamb was used as a biological tissue phantom. The scan was performed on both T1and T2-weighted without and with an electrical current injection of 0.5 mA Electrical current injection decreased mean of tissue image intensity on T1-weighted images on both muscle (1759 vs 794) and bone (2752 vs 1550) (p<0.05). On the other hand, the electrical current increased mean of tissue image intensity on T2-weighted images on both muscle (303 vs 897) and bone (579 vs 1499) (p<0.05). There is also a difference in tissue image intensity on both T1 and T2-weighted images with and without electrical current injection on bone and muscle. The implication of this difference in image quality is a subject for further study.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [41] Prediction of hard meningiomas: quantitative evaluation based on the magnetic resonance signal intensity
    Watanabe, Keita
    Kakeda, Shingo
    Yamamoto, Junkoh
    Ide, Satoru
    Ohnari, Norihiro
    Nishizawa, Shigeru
    Korogi, Yukunori
    ACTA RADIOLOGICA, 2016, 57 (03) : 333 - 340
  • [42] Supersonic transient magnetic resonance elastography for quantitative assessment of tissue elasticity
    Liu, Yu
    Liu, Jingfei
    Fite, Brett Z.
    Foiret, Josquin
    Ilovitsh, Asaf
    Leach, J. Kent
    Dumont, Erik
    Caskey, Charles F.
    Ferrara, Katherine W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (10): : 4083 - 4106
  • [43] INCREASED POTENTIAL FOR TISSUE DISCRIMINATION IN QUANTITATIVE MAGNETIC-RESONANCE-IMAGING
    PRENDERGAST, DJ
    HICKEY, DS
    JENKINS, JPR
    ISHERWOOD, I
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (719): : 1142 - 1143
  • [44] Quantitative assessment of gas cell development during the proofing of dough by magnetic resonance imaging and image analysis
    van Duynhoven, JPM
    van Kempen, GMP
    van Sluis, R
    Rieger, B
    Weegels, P
    van Vliet, LJ
    Nicolay, K
    CEREAL CHEMISTRY, 2003, 80 (04) : 390 - 395
  • [45] Reduced adipose tissue in growth-restricted fetuses using quantitative analysis of magnetic resonance images
    Rabinowich, Aviad
    Avisdris, Netanell
    Zilberman, Ayala
    Link-Sourani, Daphna
    Lazar, Sapir
    Herzlich, Jacky
    Specktor-Fadida, Bella
    Joskowicz, Leo
    Malinger, Gustavo
    Ben-Sira, Liat
    Hiersch, Liran
    Ben Bashat, Dafna
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 9194 - 9202
  • [46] Quantitative Analysis of Magnetic Resonance Image Sagittal T2 Mapping in Lumbar Spine Classification
    Su, Lianta
    Huang, Jianlong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2020, 10 (12) : 2855 - 2860
  • [47] Reduced adipose tissue in growth-restricted fetuses using quantitative analysis of magnetic resonance images
    Aviad Rabinowich
    Netanell Avisdris
    Ayala Zilberman
    Daphna Link-Sourani
    Sapir Lazar
    Jacky Herzlich
    Bella Specktor-Fadida
    Leo Joskowicz
    Gustavo Malinger
    Liat Ben-Sira
    Liran Hiersch
    Dafna Ben Bashat
    European Radiology, 2023, 33 : 9194 - 9202
  • [48] Induced Current Magnetic Resonance Electrical Conductivity Imaging With Oscillating Gradients
    Eroglu, Hasan H.
    Sadighi, Mehdi
    Eyuboglu, B. Murat
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (07) : 1606 - 1617
  • [49] Quantitative magnetic resonance imaging in prostate cancer: A review of current technology
    Dhiman, Ankita
    Kumar, Virendra
    Das, Chandan Jyoti
    WORLD JOURNAL OF RADIOLOGY, 2024, 16 (10):
  • [50] Quantitative effect of anodal current in the treatment of primary hyperhidrosis by direct electrical current
    Aydemir, Ertugrul H.
    Kalkan, M. Tunaya
    Karakoc, Yunus
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 2006, 45 (07) : 862 - 864