QUANTITATIVE ANALYSIS OF ELECTRICAL CURRENT EFFECT ON MAGNETIC RESONANCE IMAGE TISSUE INTENSITY

被引:0
|
作者
Ain, Khusnul [1 ]
Choridah, Lina [2 ]
Kurniadi, Deddy [3 ]
Garnadi, Agah D. [4 ]
Mukhaiyar, Utriweni [5 ]
Setyawan, Nurhuda Hendra [2 ]
机构
[1] Biomed Engn Airlangga Univ, Kota, Indonesia
[2] Univ Gadjah Mada, Dept Radiol, Fac Med Publ Hlth & Nursing, Yogyakarta, Indonesia
[3] Bandung Inst Technol, Dept Engn Phys, Bandung, Indonesia
[4] Bogor Agr Inst, Math & Sci, Bogor, Indonesia
[5] Bandung Inst Technol, Fac Math & Nat Sci, Stat Res Div, Bandung, Indonesia
来源
JURNAL TEKNOLOGI-SCIENCES & ENGINEERING | 2023年 / 85卷 / 02期
关键词
Magnetic resonance imaging; Tissue image intensity; T1-weighted image; T2-weighted images; MREIT; IMPEDANCE TOMOGRAPHY MREIT; CONTRAST; MRI; RESOLUTION; TOXICITY; MASS;
D O I
10.11113/jurnalteknologi.v85.18871
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent studies in magnetic resonance imaging (MRI) aim to improve image quality while reducing scan time. Electrical current injection in the form of magnetic resonance electrical impedance tomography (MREIT) is believed to be affecting image quality and scan time thus can improve the possibility of becoming a non-chemical contrast agent in MRI. This study will observe and analyze the effect of electrical current injection on a phantom object to determine whether there is a different tissue image intensity. A thigh of lamb was used as a biological tissue phantom. The scan was performed on both T1and T2-weighted without and with an electrical current injection of 0.5 mA Electrical current injection decreased mean of tissue image intensity on T1-weighted images on both muscle (1759 vs 794) and bone (2752 vs 1550) (p<0.05). On the other hand, the electrical current increased mean of tissue image intensity on T2-weighted images on both muscle (303 vs 897) and bone (579 vs 1499) (p<0.05). There is also a difference in tissue image intensity on both T1 and T2-weighted images with and without electrical current injection on bone and muscle. The implication of this difference in image quality is a subject for further study.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [31] Independent Component Analysis for Magnetic Resonance Image Analysis
    Yen-Chieh Ouyang
    Hsian-Min Chen
    Jyh-Wen Chai
    Cheng-Chieh Chen
    Clayton Chi-Chang Chen
    Sek-Kwong Poon
    Ching-Wen Yang
    San-Kan Lee
    EURASIP Journal on Advances in Signal Processing, 2008
  • [32] Magnetic resonance imaging image intensity correction with extrapolation and adaptive smoothing
    Cheng, H
    Huang, F
    MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (04) : 959 - 966
  • [33] Independent component analysis for magnetic resonance image analysis
    Ouyang, Yen-Chieh
    Chen, Hsian-Min
    Chai, Jyh-Wen
    Chen, Cheng-Chieh
    Chen, Clayton Chi-Chang
    Poon, Sek-Kwong
    Yang, Ching-Wen
    Lee, San-Kan
    EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2008, 2008 (1)
  • [34] Method for a detailed measurement of image intensity nonuniformity in magnetic resonance imaging
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2005, 32 (04) : 952 - 960
  • [35] Magnetic resonance image tissue classification using an automatic method
    Sepideh Yazdani
    Rubiyah Yusof
    Amirhosein Riazi
    Alireza Karimian
    Diagnostic Pathology, 9
  • [36] Magnetic resonance image tissue classification using an automatic method
    Yazdani, Sepideh
    Yusof, Rubiyah
    Riazi, Amirhosein
    Karimian, Alireza
    DIAGNOSTIC PATHOLOGY, 2014, 9 : 207
  • [37] Analysis of Eddy Current Effect for RF Coil of Unilateral Magnetic Resonance Sensor
    Ye, Liping
    Yu, Dengjie
    Chen, Xiyang
    Huang, Jianhua
    Lin, Jianhua
    Xia, Yunfeng
    Xu, Zheng
    4TH INTERNATIONAL CONFERENCE ON MECHANICAL AUTOMATION AND MATERIALS ENGINEERING (ICMAME 2015), 2015, : 803 - 807
  • [38] Maximum intensity projection analysis in magnetic resonance of the breast
    Carriero, A
    Di Credico, A
    Mansour, M
    Bonomo, L
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2002, 21 (03) : 77 - 81
  • [39] MULTISPECTRAL MAGNETIC RESONANCE IMAGE ANALYSIS.
    Vannier, Michael W.
    Butterfield, Robert L.
    Rickman, Douglas L.
    Jordan, Douglas M.
    Murphy, William A.
    Biondetti, Pietro R.
    1600, (15):
  • [40] Magnetic resonance of brown adipose tissue: A review of current techniques
    Department of Radiology, Phoenix Children’s Hospital, 1919 East Thomas Road, Phoenix
    AZ
    85016, United States
    Crit. Rev. Biomed. Eng., 2-3 (161-181):