QUANTITATIVE ANALYSIS OF ELECTRICAL CURRENT EFFECT ON MAGNETIC RESONANCE IMAGE TISSUE INTENSITY

被引:0
|
作者
Ain, Khusnul [1 ]
Choridah, Lina [2 ]
Kurniadi, Deddy [3 ]
Garnadi, Agah D. [4 ]
Mukhaiyar, Utriweni [5 ]
Setyawan, Nurhuda Hendra [2 ]
机构
[1] Biomed Engn Airlangga Univ, Kota, Indonesia
[2] Univ Gadjah Mada, Dept Radiol, Fac Med Publ Hlth & Nursing, Yogyakarta, Indonesia
[3] Bandung Inst Technol, Dept Engn Phys, Bandung, Indonesia
[4] Bogor Agr Inst, Math & Sci, Bogor, Indonesia
[5] Bandung Inst Technol, Fac Math & Nat Sci, Stat Res Div, Bandung, Indonesia
来源
关键词
Magnetic resonance imaging; Tissue image intensity; T1-weighted image; T2-weighted images; MREIT; IMPEDANCE TOMOGRAPHY MREIT; CONTRAST; MRI; RESOLUTION; TOXICITY; MASS;
D O I
10.11113/jurnalteknologi.v85.18871
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Recent studies in magnetic resonance imaging (MRI) aim to improve image quality while reducing scan time. Electrical current injection in the form of magnetic resonance electrical impedance tomography (MREIT) is believed to be affecting image quality and scan time thus can improve the possibility of becoming a non-chemical contrast agent in MRI. This study will observe and analyze the effect of electrical current injection on a phantom object to determine whether there is a different tissue image intensity. A thigh of lamb was used as a biological tissue phantom. The scan was performed on both T1and T2-weighted without and with an electrical current injection of 0.5 mA Electrical current injection decreased mean of tissue image intensity on T1-weighted images on both muscle (1759 vs 794) and bone (2752 vs 1550) (p<0.05). On the other hand, the electrical current increased mean of tissue image intensity on T2-weighted images on both muscle (303 vs 897) and bone (579 vs 1499) (p<0.05). There is also a difference in tissue image intensity on both T1 and T2-weighted images with and without electrical current injection on bone and muscle. The implication of this difference in image quality is a subject for further study.
引用
收藏
页码:141 / 148
页数:8
相关论文
共 50 条
  • [1] Software Design for Quantitative Analysis of Myocardial Perfusion Magnetic Resonance Image
    Yu, Lin
    Huang, Siyi
    Ma, Meng
    Yang, Xin
    Pan, Jinwei
    Wei, Men
    2013 INTERNATIONAL CONFERENCE ON CYBER SCIENCE AND ENGINEERING (CYBERSE 2013), 2013, : 85 - 90
  • [2] Effect of metallic materials on magnetic resonance image uniformity: a quantitative experimental study
    Shimamoto, Hiroaki
    Felemban, Doaa
    Uchimoto, Yuka
    Matsuda, Nobuhiko
    Takagawa, Naoko
    Takeshita, Ami
    Iwamoto, Yuri
    Okahata, Ryoko
    Tsujimoto, Tomomi
    Kreiborg, Sven
    Mallya, Sanjay M.
    Yang, Fan-pei Gloria
    ORAL RADIOLOGY, 2025, 41 (01) : 78 - 87
  • [3] Quantitative ultrasound analysis and magnetic resonance image analysis of iron accumulation in the liver of birds
    Paul-Murphy, J
    Matheson, J
    O'Brien, R
    Steinberg, H
    Waller, K
    TAKE FLIGHT IN PITTSBURGH, PROCEEDINGS, 2003, : 137 - 139
  • [4] MAGNETIC-RESONANCE IMAGE INTENSITY VALUES IN SCHIZOPHRENIA
    COFFMAN, JA
    NASRALLAH, HA
    ANDREASEN, N
    OLSON, SC
    DUNN, VD
    EHRHARDT, JC
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1987, 32 (1-2) : 325 - 325
  • [5] QUANTITATIVE MAGNETIC RESONANCE IMAGE ANALYSIS VIA THE EM ALGORITHM WITH STOCHASTIC VARIATION
    Zhang, Xiaoxi
    Johnson, Timothy D.
    Little, Roderick J. A.
    Cao, Yue
    ANNALS OF APPLIED STATISTICS, 2008, 2 (02): : 736 - 755
  • [6] Assessment of current methods of analysis for quantitative in-vivo magnetic resonance spectroscopy
    Elster, C
    Link, A
    Schubert, F
    Seifert, F
    Walzel, M
    Richter, D
    Rinneberg, H
    ADVANCED MATHEMATICAL AND COMPUTATIONAL TOOLS IN METROLOGY V, 2001, 57 : 134 - 141
  • [7] Quantitative analysis of white matter hyperintensity: Comparison of magnetic resonance imaging image analysis software
    Tabei, Ken-ichi
    Saji, Naoki
    Ogama, Noriko
    Abe, Makiko
    Omura, Saeko
    Sakurai, Takashi
    Tomimoto, Hidekazu
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2022, 31 (08):
  • [8] Quantitative magnetic resonance imaging of subcutaneous adipose tissue
    Gensanne, D.
    Josse, G.
    Theunis, J.
    Lagarde, J. M.
    Vincensini, D.
    SKIN RESEARCH AND TECHNOLOGY, 2009, 15 (01) : 45 - 50
  • [9] EFFECT OF BULK TISSUE MOTION ON QUANTITATIVE PERFUSION AND DIFFUSION MAGNETIC-RESONANCE-IMAGING
    CHENEVERT, TL
    PIPE, JG
    MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 261 - 265
  • [10] Quantitative Evaluation Method of Image Segmentation Techniques for Magnetic Resonance guided High Intensity Focused Ultrasound Therapy
    Rincon-Montes, V.
    Vargas-Olivares, A.
    Pichardo, S.
    Curiel, L.
    Chong-Quero, J. E.
    2013 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING, COMPUTING SCIENCE AND AUTOMATIC CONTROL (CCE), 2013, : 110 - 115