Electroanalytical performance of a Bismuth/Antimony composite glassy carbon electrode in detecting lead and cadmium

被引:2
|
作者
Muna, Grace W. [1 ,2 ]
Barrera, Emily [1 ]
Robinson, Lucas [1 ]
Majeed, Hiba [1 ]
Jones, Keon [1 ]
Damschroder, Abigail [1 ]
Vila, Andrew [1 ]
机构
[1] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN USA
[2] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN 46634 USA
基金
美国国家科学基金会;
关键词
antimony; bismuth; differential pulse anodic stripping voltammetry; electrodeposition; scanning electron microscopy; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH-FILM ELECTRODES; SCREEN-PRINTED ELECTRODES; PASTE ELECTRODES; TRACE-METALS; ANTIMONY;
D O I
10.1002/elan.202300019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the electroanalytical performance of a glassy carbon electrode (GCE) modified with antimony and bismuth (Sb/Bi-GCE) in detecting heavy metal ions using lead and cadmium as model analytes. The electroanalytical performance of the Sb/Bi-GCE surface was compared to the bismuth modified glassy carbon electrode (Bi-GCE) as well as the antimony modified glassy carbon electrode (Sb-GCE). The Sb/Bi-GCE exhibited excellent figures of merit compared to Bi-GCE and Sb-GCE surfaces. For example, the limit of detection for lead was 0.01 ppb using Sb/Bi-GCE and 0.1 and 1 ppb on Bi-GCE and Sb-GCE, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Incorporation of Bismuth(III) Oxide Nanoparticles into Carbon Ceramic Composite: Electrode Material with Improved Electroanalytical Performance in 4-Chloro-3-Methylphenol Determination
    Brycht, Mariola
    Leniart, Andrzej
    Skrzypek, Slawomira
    Burnat, Barbara
    MATERIALS, 2024, 17 (03)
  • [42] First Electroanalytical Studies of Profluralin with Square Wave Voltammetry Using Glassy Carbon Electrode
    Smarzewska, Sylwia
    Jasinska, Agnieszka
    Ciesielski, Witold
    Guziejewski, Dariusz
    ELECTROANALYSIS, 2017, 29 (01) : 244 - 248
  • [43] Electroanalytical Detection of Uric Acid on Blue HEGN Modified Glassy Carbon Electrode by Voltammetry
    Sukanya, S. D.
    Swamy, B. E. Kumara
    Shashikumara, J. K.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (12): : 1114 - 1125
  • [44] ELECTROANALYTICAL DETERMINATION OF IRON WITH A GLASSY-CARBON ELECTRODE MERCURY-PLATED INSITU
    OGURA, K
    MIWA, Y
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 111 (2-3) : 253 - 259
  • [45] Electroanalytical study of infrageneric relationship of Lagerstroemia using glassy carbon electrode recorded voltammograms
    Zhang, X.
    Yang, R.
    Li, Z.
    Zhang, M.
    Wang, Q.
    Xu, Y.
    Fu, L.
    Du, J.
    Zheng, Y.
    Zhu, J.
    Liu, Q.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2020, 19 : 281 - 291
  • [46] Development of an electroanalytical sensor for γ-hexachlorocyclohexane based on a cellulose acetate modified glassy carbon electrode
    Kumaravel, Ammasai
    Vincent, Susai
    Chandrasekaran, Maruthai
    ANALYTICAL METHODS, 2013, 5 (04) : 931 - 938
  • [47] Carbon composite microelectrodes:: Charge percolation and electroanalytical performance
    Ramírez-García, S
    Alegret, S
    Céspedes, F
    Forster, RJ
    ANALYTICAL CHEMISTRY, 2004, 76 (03) : 503 - 512
  • [48] Simultaneous Quantitation of Lead and Cadmium on an EDTA-Reduced Graphene Oxide-Modified Glassy Carbon Electrode
    Sridharan, Nishanthi Vasanthi
    Mandal, Badal Kumar
    ACS OMEGA, 2022, : 45469 - 45480
  • [49] Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes
    Wu, KB
    Hu, SS
    Fei, JJ
    Bai, W
    ANALYTICA CHIMICA ACTA, 2003, 489 (02) : 215 - 221
  • [50] Morphology-dependent NiO modified glassy carbon electrode surface for lead(II) and cadmium(II) detection
    Li, Xuewu
    Wen, Hao
    Fu, Qiang
    Peng, Dai
    Yu, Jingui
    Zhang, Qiaoxin
    Huang, Xingjiu
    APPLIED SURFACE SCIENCE, 2016, 363 : 7 - 12