Electroanalytical performance of a Bismuth/Antimony composite glassy carbon electrode in detecting lead and cadmium

被引:2
|
作者
Muna, Grace W. [1 ,2 ]
Barrera, Emily [1 ]
Robinson, Lucas [1 ]
Majeed, Hiba [1 ]
Jones, Keon [1 ]
Damschroder, Abigail [1 ]
Vila, Andrew [1 ]
机构
[1] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN USA
[2] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN 46634 USA
基金
美国国家科学基金会;
关键词
antimony; bismuth; differential pulse anodic stripping voltammetry; electrodeposition; scanning electron microscopy; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH-FILM ELECTRODES; SCREEN-PRINTED ELECTRODES; PASTE ELECTRODES; TRACE-METALS; ANTIMONY;
D O I
10.1002/elan.202300019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the electroanalytical performance of a glassy carbon electrode (GCE) modified with antimony and bismuth (Sb/Bi-GCE) in detecting heavy metal ions using lead and cadmium as model analytes. The electroanalytical performance of the Sb/Bi-GCE surface was compared to the bismuth modified glassy carbon electrode (Bi-GCE) as well as the antimony modified glassy carbon electrode (Sb-GCE). The Sb/Bi-GCE exhibited excellent figures of merit compared to Bi-GCE and Sb-GCE surfaces. For example, the limit of detection for lead was 0.01 ppb using Sb/Bi-GCE and 0.1 and 1 ppb on Bi-GCE and Sb-GCE, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Electrochemical/chemical synthesis of hydroxyapatite on glassy carbon electrode for electroanalytical determination of cysteine
    Vladislavic, Nives
    Roncevic, Ivana Skugor
    Buzuk, Marijo
    Buljac, Masa
    Drventic, Ivana
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2021, 25 (03) : 841 - 857
  • [32] Mutual Influence of Lead and Cadmium Ions on Bismuth Film Electrode
    Han Yan-Chao
    Wei Ting
    Li Jing
    Jia Xiao-Fang
    Li Dong-Yue
    Zhang Xiao-Wei
    Wang Er-Kang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (10) : 1539 - 1543
  • [33] A Simple Electroanalytical Method for Detecting Carminic Acid in Foods through a Glassy Carbon Electrode Modified with Chitosan in the Presence of Allura Red
    Nagles, Edgar
    Rodriguez, Maria A.
    Flores-Velasquez, Gabriela
    Garcia, Holger Jelimer Maldonado
    Hurtado, John J. J.
    CHEMISTRYSELECT, 2023, 8 (32):
  • [34] Electroanalytical Determination of Cadmium(II) and Lead(II) Using an in-situ Bismuth Film Modified Edge Plane Pyrolytic Graphite Electrode
    Roohollah Torabi Kachoosangi
    Craig E. Banks
    Xiaobo Ji
    Richard G. Compton
    Analytical Sciences, 2007, 23 : 283 - 289
  • [35] Electroanalytical determination of cadmium(II) and lead(II) using an in-situ bismuth film modified edge plane pyrolytic graphite electrode
    Kachoosangi, Roohollah Torabi
    Banks, Craig E.
    Ji, Xiaobo
    Compton, Richard G.
    ANALYTICAL SCIENCES, 2007, 23 (03) : 283 - 289
  • [36] Application of an in situ Bismuth-coated Glassy Carbon Electrode for Electroanalytical Determination of Cd (II) and Pb (II) in Korean Polished Rices
    Kim, Hak-Jin
    Son, Dong-Wook
    Park, Jong-Min
    Hwang, Dae Youn
    Mo, Chang-Youn
    Park, Sang-Won
    Kim, Giyoung
    Eun, Jong-Bang
    FOOD SCIENCE AND BIOTECHNOLOGY, 2010, 19 (05) : 1211 - 1217
  • [37] Application of an in situ bismuth-coated glassy carbon electrode for electroanalytical determination of Cd (II) and Pb (II) in Korean polished rices
    Hak-Jin Kim
    Dong-Wook Son
    Jong-Min Park
    Dae Youn Hwang
    Chang-Youn Mo
    Sang-Won Park
    Giyoung Kim
    Jong-Bang Eun
    Food Science and Biotechnology, 2010, 19 : 1211 - 1217
  • [38] Stripping Potentiometry of Lead, Cadmium and Copper at a Nafion Coated Glassy Carbon Electrode with Encapsulated Mercury Acetate
    Macca, C.
    Bradshaw, M.
    Merkoci, A.
    Scollary, G.
    Analytical Letters, 30 (06):
  • [39] Stripping potentiometry of lead, cadmium and copper at a nafion coated glassy carbon electrode with encapsulated mercury acetate
    Macca, C
    Bradshaw, M
    Merkoci, A
    Scollary, G
    ANALYTICAL LETTERS, 1997, 30 (06) : 1223 - 1234
  • [40] A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants
    Chamjangali, M. Arab
    Kouhestani, H.
    Masdarolomoor, F.
    Daneshinejad, H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 384 - 393