Electroanalytical performance of a Bismuth/Antimony composite glassy carbon electrode in detecting lead and cadmium

被引:2
|
作者
Muna, Grace W. [1 ,2 ]
Barrera, Emily [1 ]
Robinson, Lucas [1 ]
Majeed, Hiba [1 ]
Jones, Keon [1 ]
Damschroder, Abigail [1 ]
Vila, Andrew [1 ]
机构
[1] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN USA
[2] Indiana Univ South Bend, Dept Chem & Biochem, South Bend, IN 46634 USA
基金
美国国家科学基金会;
关键词
antimony; bismuth; differential pulse anodic stripping voltammetry; electrodeposition; scanning electron microscopy; ANODIC-STRIPPING VOLTAMMETRY; BISMUTH-FILM ELECTRODES; SCREEN-PRINTED ELECTRODES; PASTE ELECTRODES; TRACE-METALS; ANTIMONY;
D O I
10.1002/elan.202300019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports on the electroanalytical performance of a glassy carbon electrode (GCE) modified with antimony and bismuth (Sb/Bi-GCE) in detecting heavy metal ions using lead and cadmium as model analytes. The electroanalytical performance of the Sb/Bi-GCE surface was compared to the bismuth modified glassy carbon electrode (Bi-GCE) as well as the antimony modified glassy carbon electrode (Sb-GCE). The Sb/Bi-GCE exhibited excellent figures of merit compared to Bi-GCE and Sb-GCE surfaces. For example, the limit of detection for lead was 0.01 ppb using Sb/Bi-GCE and 0.1 and 1 ppb on Bi-GCE and Sb-GCE, respectively.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Determination of trace amounts of lead and cadmium using a bismuth/glassy carbon composite electrode
    Hwang, Gil-Ho
    Han, Won-Kyu
    Hong, Seok-Jun
    Park, Joon-Shik
    Kang, Sung-Goon
    TALANTA, 2009, 77 (04) : 1432 - 1436
  • [2] The Influence of the Electrodeposition Conditions on the Electroanalytical Performance of the Bismuth Film Electrode for Lead Determination
    Nunes, Luiza M. S.
    Faria, Ronaldo C.
    ELECTROANALYSIS, 2008, 20 (20) : 2259 - 2263
  • [3] A study on the electroanalytical performance of a bismuth film-coated and Nafion-coated glassy carbon electrode in alkaline solutions
    Dongyue Li
    Jianbo Jia
    Jianguo Wang
    Microchimica Acta, 2010, 169 : 221 - 225
  • [4] A study on the electroanalytical performance of a bismuth film-coated and Nafion-coated glassy carbon electrode in alkaline solutions
    Li, Dongyue
    Jia, Jianbo
    Wang, Jianguo
    MICROCHIMICA ACTA, 2010, 169 (3-4) : 221 - 225
  • [5] A glassy carbon electrode modified with bismuth nanotubes in a silsesquioxane framework for sensing of trace lead and cadmium by stripping voltammetry
    Li, Yusong
    Sun, Guangqiang
    Zhang, Yuehua
    Ge, Cunwang
    Bao, Ning
    Wang, Yihong
    MICROCHIMICA ACTA, 2014, 181 (7-8) : 751 - 757
  • [6] A glassy carbon electrode modified with bismuth nanotubes in a silsesquioxane framework for sensing of trace lead and cadmium by stripping voltammetry
    Yusong Li
    Guangqiang Sun
    Yuehua Zhang
    Cunwang Ge
    Ning Bao
    Yihong Wang
    Microchimica Acta, 2014, 181 : 751 - 757
  • [7] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Lemma Teshome Tufa
    Khalid Siraj
    Tesfaye Refera Soreta
    Russian Journal of Electrochemistry, 2013, 49 : 59 - 66
  • [8] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Tufa, Lemma Teshome
    Siraj, Khalid
    Soreta, Tesfaye Refera
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (01) : 59 - 66
  • [9] Electroanalytical Investigation of Paracetamol on Glassy Carbon Electrode by Voltammetry
    Engin, C.
    Yilmaz, S.
    Saglikoglu, G.
    Yagmur, S.
    Sadikoglu, M.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2015, 10 (02): : 1916 - 1926
  • [10] GLASSY-CARBON AS ELECTRODE MATERIAL IN ELECTROANALYTICAL CHEMISTRY
    VANDERLINDEN, WE
    DIEKER, JW
    ANALYTICA CHIMICA ACTA, 1980, 119 (01) : 1 - 24