摘要
In order to solve the problems of performance degradation in energy tower heat pump (ETHP) systems under low temperature conditions and soil heat imbalances in ground source heat pump (GSHP) systems in cold regions, a new coupled system of ETHP and GSHP systems (the ET-GSHP system) and its operating mode were proposed. The mathematical model of the system was constructed along with the system's form and operation scheme. The COP (coefficient of performance) and total energy consumption of the coupled system were then simulated and studied under a number of common operating situations. The heating season is divided into four periods based on varying outdoor ambient temperatures: the first period operates in series mode and has an average outdoor temperature of 2.38 & DEG;C; the second period operates in parallel mode and has an average outdoor temperature of -8.56 & DEG;C; the third period uses soil source heat pumps to operate separately; and the fourth period operates in series mode and has an average outdoor temperature of -11.32 & DEG;C. Operation of the coupled system in four periods was simulated and analyzed, and the operational efficiency and energy saving of the system were analyzed using an actual commercial building in a cold region as an example. The results demonstrate that the ET-GSHP system's overall energy consumption during the heating period is reduced by 4.34% when compared to the traditional GSHP systems; the system's COP can maintain a high level throughout the heating period, with an average COP of 3.315; and the soil temperature at the conclusion of the heating period is 25 & DEG;C, which is 8.89 & DEG;C higher than that of the traditional GSHP system, providing a guarantee of summer heat return. The new ET-GSHP system significantly boosts the efficiency of the system's operation, achieves effective coupling between various heat sources through multi-stage control, and offers improved energy-saving advantages.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Case study on optimal design and operation of detached house energy system: Solar, battery, and ground source heat pump
    Nordgard-Hansen, Ellen
    Kishor, Nand
    Midttomme, Kirsti
    Risinggard, Vetle Kjaer
    Kocbach, Jan
    APPLIED ENERGY, 2022, 308
  • [42] A Hybrid System based on Heat Sink Form with Solar Energy and Ground Source Heat Pump
    Ma, Shuling
    Ding, Yan
    Shi, Xinli
    Zhu, Neng
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 7 - +
  • [43] Hydraulic characteristics and optimization of integrated heat source tower heat pump energy station tower side
    Chen X.
    Liang C.
    You Y.
    Zhou Q.
    Zhang X.
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2022, 53 (12): : 4809 - 4817
  • [44] Economic and environmental analysis of ground source heat pump system according to operation methods
    Bae, Sangmu
    Nam, Yujin
    GEOTHERMICS, 2022, 101
  • [45] Static analysis on energy consumption of water loop heat pump system
    Ma, Zuiliang
    Cao, Yuan
    Harbin Jianzhu Daxue Xuebao/Journal of Harbin University of Civil Engineering and Architecture, 30 (06): : 68 - 74
  • [46] Analysis of the operation performance of a hybrid solar ground-source heat pump system
    Zhang, Xueyou
    Wang, Enyu
    Liu, Liansheng
    Qi, Chengying
    Zhen, Jinyu
    Meng, Ying
    ENERGY AND BUILDINGS, 2022, 268
  • [47] Forecast and analysis of long-term operation of ground source heat pump system
    Qi, Zi-Shu
    Gao, Qing
    Yu, Ming
    Liu, Yan
    Bai, Li
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2012, 42 (04): : 877 - 881
  • [48] Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
    Han J.
    Zhang C.
    Wang L.
    Chang Z.
    Zhao Q.
    Shi Y.
    Wu J.
    Kong X.
    Energy Engineering: Journal of the Association of Energy Engineering, 2023, 120 (09): : 1991 - 2011
  • [49] Integrated operation of PV assisted ground source heat pump and air source heat pump system: Performance analysis and economic optimization
    Zheng, Zhihang
    Zhou, Jin
    Xu, Feng
    Zhang, Rongpeng
    Deng, Guang
    ENERGY CONVERSION AND MANAGEMENT, 2022, 269
  • [50] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    ENERGY, 2013, 51 : 349 - 357