Biomechanical evaluation of a novel biomimetic artificial intervertebral disc in canine cervical cadaveric spines

被引:0
|
作者
Jacobs, Celien A. M. [1 ]
Doodkorte, Remco J. P. [2 ]
Kamali, S. Amir [3 ]
Abdelgawad, Abdelrahman M.
Ghazanfari, Samaneh [4 ]
Jockenhoevel, Stefan [4 ,5 ]
Arts, J. J. Chris [1 ,2 ]
Tryfonidou, Marianna A. [3 ]
Meij, Bjorn P. [3 ]
Ito, Keita [1 ,6 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Orthoped Biomech, Eindhoven, Noord Brabant, Netherlands
[2] Maastricht Univ Med Ctr, Res Sch CAPHRI, Dept Orthoped Surg, Maastricht, Limburg, Netherlands
[3] Univ Utrecht, Fac Vet Med, Dept Clin Sci, Utrecht, Utrecht, Netherlands
[4] Maastricht Univ, Aachen Maastricht Inst Biobased Mat, Fac Sci & Engn, Geleen, Limburg, Netherlands
[5] Rhein Westfal TH Aachen, AME Inst Appl Med Engn, Helmholtz Inst, Dept Biohybrid & Med Text BioTex, Aachen, Nordrhein Westf, Germany
[6] Eindhoven Univ Technol, Dept Biomed Engn, Orthoped Biomech, Rondom 70, NL-5612 Eindhoven, Noord Brabant, Netherlands
来源
JOR SPINE | 2023年 / 6卷 / 02期
关键词
biomechanical; biomimetic artificial disc; cervical spine; kinematics; total disc replacement; INTRADISCAL PRESSURE; ARTHROPLASTY; ADJACENT; FUSION; REPLACEMENT; LEVEL; SINGLE; DISKECTOMY; MYELOPATHY; OUTCOMES;
D O I
10.1002/jsp2.1251
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Context: Cervical disc replacement (CDR) aims to restore motion of the treated level to reduce the risk of adjacent segment disease (ASD) compared with spinal fusion. However, first-generation articulating devices are unable to mimic the complex deformation kinematics of a natural disc. Thus, a biomimetic artificial intervertebral CDR (bioAID), containing a hydroxyethylmethacrylate (HEMA)-sodium methacrylate (NaMA) hydrogel core representing the nucleus pulposus, an ultra-high-molecular-weight-polyethylene fiber jacket as annulus fibrosus, and titanium endplates with pins for primary mechanical fixation, was developed.Purpose: To assess the initial biomechanical effect of the bioAID on the kinematic behavior of the canine spine, an ex vivo biomechanical study in 6-degrees-of-freedom was performed.Study Design: A canine cadaveric biomechanical study.Methods: Six cadaveric canine specimens (C3-C6) were tested in flexion-extension (FE), lateral bending (LB) axial rotation (AR) using a spine tester in three conditions: intact, after C4-C5 disc replacement with bioAID, and after C4-C5 interbody fusion. A hybrid protocol was used where first the intact spines were subjected to a pure moment of & PLUSMN;1 Nm, whereafter the treated spines were subjected to the full range of motion (ROM) of the intact condition. 3D segmental motions at all levels were measured while recording the reaction torsion. Biomechanical parameters studied included ROM, neutral zone (NZ), and intradiscal pressure (IDP) at the adjacent cranial level (C3-C4).Results: The bioAID retained the sigmoid shape of the moment-rotation curves with a NZ similar to the intact condition in LB and FE. Additionally, the normalized ROMs at the bioAID-treated level were statistically equivalent to intact during FE and AR while slightly decreased in LB. At the two adjacent levels, ROMs showed similar values for the intact compared to the bioAID for FE and AR and an increase in LB. In contrast, levels adjacent to the fused segment showed an increased motion in FE and LB as compensation for the loss of motion at the treated level. The IDP at the adjacent C3-C4 level after implantation of bioAID was close to intact values. After fusion, increased IDP was found compared with intact but did not reach statistical significance.Conclusion: This study indicates that the bioAID can mimic the kinematic behavior of the replaced intervertebral disc and preserves that for the adjacent levels better than fusion. As a result, CDR using the novel bioAID is a promising alternative treatment for replacing severely degenerated intervertebral discs.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Hybrid Strategy of Two-Level Cervical Artificial Disc and Intervertebral Cage Biomechanical Effects on Tissues and Implants
    Chung, Tzu-Tsao
    Hueng, Dueng-Yuan
    Lin, Shang-Chih
    MEDICINE, 2015, 94 (47) : e2048
  • [22] Biomechanical evaluation of a novel repair strategy for intervertebral disc herniation in an ovine lumbar spine model
    Page, Mitchell I.
    Easley, Jeremiah T.
    Bonilla, Andres F.
    Patel, Vikas V.
    Puttlitz, Christian M.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 10
  • [23] Biomechanical evaluation of a novel intervertebral disc repair technique for large box-shaped ruptures
    Nie, Mao-Dan
    Huang, Ze-Bin
    Zhang, Ning-Ze
    Fu, Ling-Jie
    Cheng, Cheng-Kung
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [24] The biomechanical impact of facet tropism on the intervertebral disc and facet joints in the cervical spine
    Rong, Xin
    Wang, Beiyu
    Ding, Chen
    Deng, Yuxiao
    Chen, Hua
    Meng, Yang
    Yan, Weijie
    Liu, Hao
    SPINE JOURNAL, 2017, 17 (12): : 1926 - 1931
  • [25] A biomimetic artificial disc with improved mechanical properties compared to biological intervertebral discs
    Shikinami, Y
    Kotani, Y
    Cunningham, BW
    Abumi, K
    Kaneda, K
    ADVANCED FUNCTIONAL MATERIALS, 2004, 14 (11) : 1039 - 1046
  • [26] Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement
    Zhao, Xin
    Yuan, Wei
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (05): : 3109 - 3115
  • [27] Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement
    Huang, Kangkang
    Wu, Tingkui
    Wang, Beiyu
    Liu, Hao
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2019, 11 (10):
  • [28] EVALUATION OF BIOMECHANICAL PERFORMANCES OF ELECTROSPUN FIBER ANCHORED SILICONE DISC AS AN INTERVERTEBRAL DISC IMPLANT
    Tummala, Subhakar
    Dogan, Oguz
    Karpat, Fatih
    Riahinezhad, Shahram
    Khandaker, M.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2017, VOL 3, 2018,
  • [29] Comparison of biomechanical properties of cervical artificial disc prosthesis: A review
    Bartels, Ronald H. M. A.
    Donk, Roland D.
    Pavlov, Paul
    van Limbeek, Jacques
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2008, 110 (10) : 963 - 967
  • [30] Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc
    Denozière, G
    Ku, DN
    JOURNAL OF BIOMECHANICS, 2006, 39 (04) : 766 - 775