Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test-retest study

被引:5
|
作者
Christensen, Nana Louise [1 ,2 ,3 ]
Sorensen, Jens [1 ]
Bouchelouche, Kirsten [1 ,3 ]
Madsen, Michael Alle [3 ]
Buhl, Christian Selmer [2 ]
Tolbod, Lars Poulsen [1 ,3 ]
机构
[1] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 165, DK-8200 Aarhus, Denmark
[2] Aarhus Univ Hosp, Steno Diabet Ctr Aarhus, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Nucl Med & PET, Aarhus, Denmark
关键词
TUMOR BLOOD-FLOW; DYNAMIC PET; FOOT; OXYGEN-15-WATER; QUANTIFICATION; O-15-WATER; VOLUME;
D O I
10.1186/s13550-024-01073-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background [O-15]H2O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [O-15]H2O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [O-15]H2O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K1 values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans. Results Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98). Conclusion Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Correction to: A retrospective evaluation of Bayesian-penalized likelihood reconstruction for [15O]H2O myocardial perfusion imaging
    Reetta Siekkinen
    Chunlei Han
    Teemu Maaniitty
    Mika Teräs
    Juhani Knuuti
    Antti Saraste
    Jarmo Teuho
    Journal of Nuclear Cardiology, 2023, 30 : 1253 - 1253
  • [32] Adenosine-induced splenic switch-off on [15O]H2O PET perfusion for the assessment of vascular vasodilatation
    Inkinen, Satu Irene
    Hippelainen, Eero
    Uusitalo, Valtteri
    EJNMMI RESEARCH, 2023, 13 (01)
  • [33] Adenosine-induced splenic switch-off on [15O]H2O PET perfusion for the assessment of vascular vasodilatation
    Satu Irene Inkinen
    Eero Hippeläinen
    Valtteri Uusitalo
    EJNMMI Research, 13
  • [34] Quantification of the hepatic oxygen consumption by [15O]H2O and [15O]O2 PET:: Relationship between tissue oxygenation and O2 consumption.
    Piert, M
    Becker, G
    Stahlschmidt, A
    Dohmen, B
    Machulla, HJ
    Bares, R
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 131P - 131P
  • [35] Quantitative measurement of regional porcine hepatic blood flow by [15O]H2O and[15O]CO positron emission tomography (PET)
    Fischer, H
    Piert, M
    Becker, G
    Machulla, HJ
    Patt, M
    Lauchart, W
    Becker, HD
    LANGENBECKS ARCHIVES OF SURGERY, 1999, : 679 - 685
  • [36] Noninvasive parametric blood flow imaging of head and neck tumours using [15O]H2O and PET/CT
    Komar, Gaber
    Oikonen, Vesa
    Sipila, Hannu
    Seppanen, Marko
    Minn, Heikki
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (11) : 1169 - 1178
  • [37] Validation of the Berlin Grading System for moyamoya angiopathy with the use of [15O]H2O PET
    R. Mertens
    G. Acker
    K. Kersting
    C. Lange
    C. Furth
    D. Beyaztas
    P. Truckenmueller
    L. Moedl
    E. D. Spruenken
    M. Czabanka
    P. Vajkoczy
    Neurosurgical Review, 46
  • [38] Warranty period of normal CCTA and [15O]H2O PET in chest pain patients
    Jukema, R.
    Maaniitty, T.
    Van Diemen, P.
    Berkhof, H.
    Raijmakers, P.
    Sprengers, R.
    Planken, R.
    Knaapen, P.
    Saraste, A.
    Danad, I.
    Knuuti, J.
    EUROPEAN HEART JOURNAL, 2022, 43 : 339 - 339
  • [39] Measurements of rCBF using [15O]H2O and the HRRT PET scanner: Optimization of methods
    Walker, Matthew D.
    Feldmann, Maria
    Anton, Jose
    Wang, Shaonan
    Koepp, Matthias
    Asselin, Marie-Claude
    NEUROIMAGE, 2010, 52 : S213 - S214
  • [40] Intravenous D-fenfluramine challenge with [15O] H2O PET in panic disorder
    Meyer, JH
    Swinson, R
    Houle, S
    Kennedy, S
    Brown, GM
    BIOLOGICAL PSYCHIATRY, 1998, 43 : 20S - 21S