Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test-retest study

被引:5
|
作者
Christensen, Nana Louise [1 ,2 ,3 ]
Sorensen, Jens [1 ]
Bouchelouche, Kirsten [1 ,3 ]
Madsen, Michael Alle [3 ]
Buhl, Christian Selmer [2 ]
Tolbod, Lars Poulsen [1 ,3 ]
机构
[1] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 165, DK-8200 Aarhus, Denmark
[2] Aarhus Univ Hosp, Steno Diabet Ctr Aarhus, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Nucl Med & PET, Aarhus, Denmark
关键词
TUMOR BLOOD-FLOW; DYNAMIC PET; FOOT; OXYGEN-15-WATER; QUANTIFICATION; O-15-WATER; VOLUME;
D O I
10.1186/s13550-024-01073-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background [O-15]H2O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [O-15]H2O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [O-15]H2O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K1 values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans. Results Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98). Conclusion Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Imaging of the appearance time of cerebral blood using [15O]H2O PET for the computation of correct CBF
    Kudomi, Nobuyuki
    Maeda, Yukito
    Sasakawa, Yasuhiro
    Monden, Toshihide
    Yamamoto, Yuka
    Kawai, Nobuyuki
    Iida, Hidehiro
    Nishiyama, Yoshihiro
    EJNMMI RESEARCH, 2013, 3 : 1 - 10
  • [22] [15O]H2O PET imaging of speech processing in cochlear implant users and normal hearing individuals
    Ciesla, Katarzyna
    Wolak, Tomasz
    Wrobel, Marek
    Walkowiak, Adam
    Malkowski, Bogdan
    Skarzynski, Henryk
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [23] Imaging of the appearance time of cerebral blood using [15O]H2O PET for the computation of correct CBF
    Nobuyuki Kudomi
    Yukito Maeda
    Yasuhiro Sasakawa
    Toshihide Monden
    Yuka Yamamoto
    Nobuyuki Kawai
    Hidehiro Iida
    Yoshihiro Nishiyama
    EJNMMI Research, 3
  • [24] Evaluative processing of ambivalent stimuli in patients with schizophrenia and depression: A [15O] H2O PET study
    Kin, Jae-Jin
    Park, Hae-Jeong
    Jung, Young-Chul
    Chun, Ji Won
    Kim, Hye Sun
    Seok, Jeong Ho
    Kim, Nam Wook
    Park, Il Ho
    Oh, Maeng-Gun
    Lee, Jong Doo
    JOURNAL OF THE INTERNATIONAL NEUROPSYCHOLOGICAL SOCIETY, 2009, 15 (06) : 990 - 1001
  • [25] Clomipramine challenge studied by [15O]H2O PET:: focus on the thalamus.
    Smith, DF
    Geday, J
    NEUROIMAGE, 2001, 13 (06) : S1102 - S1102
  • [26] Self recognition process in normal and schizophrenia by using [15O]H2O pet
    Youn, T
    Kwon, JS
    Kim, JJ
    SCHIZOPHRENIA BULLETIN, 2005, 31 (02) : 440 - 441
  • [27] A system for continuous production and infusion of [15O]H2O for PET activation studies
    Sajjad, M
    Liow, JS
    Moreno-Cantu, J
    APPLIED RADIATION AND ISOTOPES, 2000, 52 (02) : 205 - 210
  • [28] Quantification of the hepatic oxygen consumption by [15O]H2O and [15O]O2 PET:: Relationship between tissue oxygenation and oxygen consumption
    Piert, M
    Becker, G
    Fischer, H
    Machulla, HJ
    Lauchart, W
    Bares, R
    Becker, HD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (09): : 1038 - 1038
  • [29] Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography
    Everaars, Henk
    van Diemen, Pepijn A.
    Bom, Michiel J.
    Schumacher, Stefan P.
    de Winter, Ruben W.
    van de Ven, Peter M.
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Hofman, Mark B. M.
    van Der Geest, Rob J.
    Gotte, Marco J.
    van Rossum, Albert C.
    Nijveldt, Robin
    Danad, Ibrahim
    Driessen, Roel S.
    Knaapen, Paul
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (07) : 1688 - 1697
  • [30] Comparison between quantitative cardiac magnetic resonance perfusion imaging and [15O]H2O positron emission tomography
    Henk Everaars
    Pepijn A. van Diemen
    Michiel J. Bom
    Stefan P. Schumacher
    Ruben W. de Winter
    Peter M. van de Ven
    Pieter G. Raijmakers
    Adriaan A. Lammertsma
    Mark B. M. Hofman
    Rob J. van der Geest
    Marco J. Götte
    Albert C. van Rossum
    Robin Nijveldt
    Ibrahim Danad
    Roel S. Driessen
    Paul Knaapen
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 1688 - 1697