Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test-retest study

被引:5
|
作者
Christensen, Nana Louise [1 ,2 ,3 ]
Sorensen, Jens [1 ]
Bouchelouche, Kirsten [1 ,3 ]
Madsen, Michael Alle [3 ]
Buhl, Christian Selmer [2 ]
Tolbod, Lars Poulsen [1 ,3 ]
机构
[1] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 165, DK-8200 Aarhus, Denmark
[2] Aarhus Univ Hosp, Steno Diabet Ctr Aarhus, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Nucl Med & PET, Aarhus, Denmark
关键词
TUMOR BLOOD-FLOW; DYNAMIC PET; FOOT; OXYGEN-15-WATER; QUANTIFICATION; O-15-WATER; VOLUME;
D O I
10.1186/s13550-024-01073-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background [O-15]H2O PET/CT allows noninvasive quantification of tissue perfusion and can potentially play a future role in the diagnosis and treatment of peripheral artery disease. We aimed to evaluate the reliability of dynamic [O-15]H2O PET imaging for measuring lower extremity skeletal muscle perfusion. Ten healthy participants underwent same-day test-retest study with six dynamic [O-15]H2O PET scans of lower legs and feet. Manual volume-of-interests were drawn in skeletal muscles, and PET time activity curves were extracted. K1 values (mL/min/100 mL) were estimated using a single-tissue compartment model (1TCM), autoradiography (ARG), and parametric imaging with blood input functions obtained from separate heart scans. Results Resting perfusion values in the muscle groups of the lower legs ranged from 1.18 to 5.38 mL/min/100 mL (ARG method). In the muscle groups of the feet, perfusion values ranged from 0.41 to 3.41 mL/min/100 mL (ARG method). Test-retest scans demonstrated a strong correlation and good repeatability for skeletal muscle perfusion with an intraclass correlation coefficient (ICC) of 0.88 and 0.87 and a repeatability coefficient of 34% and 53% for lower legs and feet, respectively. An excellent correlation was demonstrated when comparing volume-of-interest-based methods (1TCM and ARG) (lower legs: ICC = 0.96, feet: ICC = 0.99). Parametric images were in excellent agreement with the volume-of-interest-based ARG method (lower legs: ICC = 0.97, feet: ICC = 0.98). Conclusion Parametric images and volume-of-interest-based methods demonstrated comparable resting perfusion values in the lower legs and feet of healthy individuals. The largest variation was seen between individuals, whereas a smaller variation was seen between muscle groups. Repeated measurements of resting blood flow yielded a strong overall correlation for all methods.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Repeatability of [15O]H2O PET imaging for lower extremity skeletal muscle perfusion: a test–retest study
    Nana Louise Christensen
    Jens Sørensen
    Kirsten Bouchelouche
    Michael Alle Madsen
    Christian Selmer Buhl
    Lars Poulsen Tolbod
    EJNMMI Research, 14
  • [2] [15O]H2O 15 O]H 2 O PET: Potential or Essential for Molecular Imaging?
    Slart, Riemer H. J. A.
    Martinez-Lucio, T. Samara
    Boersma, Hendrikus H.
    Borra, Ronald H.
    Cornelissen, Bart
    Dierckx, Rudi A. J. O.
    Dobrolinska, Magdalena
    Doorduin, Janine
    Erba, Paola A.
    Glaudemans, Andor W. J. M.
    Giacobbo, Bruno Lima
    Luurtsema, Gert
    Noordzij, Walter
    van Sluis, Joyce
    Tsoumpas, Charalampos
    Lammertsma, Adriaan A.
    SEMINARS IN NUCLEAR MEDICINE, 2024, 54 (05) : 761 - 773
  • [3] Pulmonary embolism as an incidental finding in [15O]H2O PET/CT myocardial perfusion imaging
    Nagel, Julie Loft
    Tolbod, Lars Poulsen
    Harms, Hendrik Johannes
    Gormsen, Lars Christian
    Madsen, Michael Alle
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 52 (01) : 368 - 369
  • [4] A continuous [15O]H2O production and infusion system for PET imaging
    Sajjad, M
    Liow, JS
    APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY, PTS 1 AND 2, 1999, 475 : 998 - 1001
  • [5] Orgasm in the female brain: a [15O]-H2O PET study.
    Georgiadis, J.
    Kuipers, R.
    Nieuwenburg, A.
    Pruim, J.
    Kortekaas, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S289 - S290
  • [6] The processing of ambivalent stimuli in schizophrenia : A [15O] H2O pet study
    Kim, J.
    Jung, Y. C.
    Park, I. H.
    Chun, J. W.
    Seok, J. H.
    Lim, J. S.
    Park, H. J.
    Lee, J. D.
    SCHIZOPHRENIA BULLETIN, 2007, 33 (02) : 373 - 373
  • [7] Parametric renal blood flow imaging using [15O]H2O and PET
    Nobuyuki Kudomi
    Niina Koivuviita
    Kaisa E. Liukko
    Vesa J. Oikonen
    Tuula Tolvanen
    Hidehiro Iida
    Risto Tertti
    Kaj Metsärinne
    Patricia Iozzo
    Pirjo Nuutila
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 683 - 691
  • [8] Parametric renal blood flow imaging using [15O]H2O and PET
    Kudomi, Nobuyuki
    Koivuviita, Niina
    Liukko, Kaisa E.
    Oikonen, Vesa J.
    Tolvanen, Tuula
    Iida, Hidehiro
    Tertti, Risto
    Metsarinne, Kaj
    Iozzo, Patricia
    Nuutila, Pirjo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (04) : 683 - 691
  • [9] 82Rb and [15O]H2O myocardial perfusion PET imaging: a prospective head to head comparison
    Krakauer, Martin
    Ismail, Afefah
    Talleruphuus, Ulrik
    Henriksen, Alexander Cuculiza
    Lonsdale, Markus N.
    Rasmussen, Inge Lise
    Fuglsang, Stefan
    Prescott, Eva
    Hovind, Peter
    Marner, Lisbeth
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (06) : 2790 - 2802
  • [10] 82Rb and [15O]H2O Myocardial perfusion PET imaging - a prospective head to head comparison
    Marner, L.
    Krakauer, M.
    Ismail, A.
    Talleruphuus, U.
    Henriksen, A. C.
    Lonsdale, M. N.
    Rasmussen, I. L.
    Fuglsang, S.
    Prescott, E.
    Hovind, P.
    Marner, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S169 - S169