An experimental study on hybrid fibre reinforced engineered cementitious composite link slabs under static and fatigue loadings

被引:4
|
作者
Zhu, Shiyao [1 ]
Zhang, Y. X. [2 ]
Lee, C. K. [1 ]
机构
[1] Univ New South Wales, Sch Engn & Technol, Canberra, ACT 2600, Australia
[2] Western Sydney Univ, Sch Engn Design & Built Environm, Kingswood, NSW 2751, Australia
关键词
Engineered cementitious composite (ECC); Hybrid fibres; Link slab; Fatigue test; Crack width control; BEHAVIOR; DESIGN;
D O I
10.1016/j.engstruct.2023.117254
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study conducted experimental investigations on the structural performances of link slabs which are con-structed by using a newly developed hybrid-fibre reinforced engineered cementitious composite (hybrid-ECC). Both static and fatigue loadings were applied to validate the feasibility, provide a proof of concept study and demonstrate the benefits using hybrid-ECC for bridge link slabs application. Three identical quarter-scaled hybrid-ECC link slabs, simulating a link slab used for a typical 35-meter multi-span simply supported bridge, were fabricated. These slabs, denoted as LS-1, LS-2 and LS-3, were tested under designated static and fatigue loadings. Slab LS-1 was tested under static loading to obtain the flexural strength of the slab. Slabs LS-2 and LS-3 were tested under fatigue loadings to evaluate their fatigue performances under normal service loading and overload scenarios, respectively. Structural performances of these slabs in terms of deformation and crack width control capability, strain development on reinforcement bars and estimated service life were evaluated. It was observed that multiple microcracks were developed under both static and fatigue loadings. Slab LS-2 survived ten million cycles of service fatigue loading while LS-3 survived two million cycles of overload fatigue loading. For all the tests conducted under static and fatigue loadings, the maximum crack width observed on the three link slab samples was all controlled within the allowable limit of 0.2 mm until failure occurred. Based on the test results, it was estimated that if only the effects due to normal traffic loading and temperature variation were considered, the hybrid-ECC link slab could achieve a service life of more than 40 years. Therefore, the experi-mental study reconfirmed that the hybrid-ECC showed a high potential to improve the fatigue performance and extend the service life of link slab in bridge construction.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] RC Slabs Repaired and Strengthened by Alumina/Polymer Mortar and Prestressing Strands in the Tension Zone: Experimental Investigation Under Static and Fatigue Loadings
    Han, K. B.
    Hong, S. N.
    Park, S. K.
    MECHANICS OF COMPOSITE MATERIALS, 2012, 48 (05) : 587 - 602
  • [42] Monotonic and fatigue performance in bending of fiber-reinforced engineered cementitious composite in overlay system
    Zhang, J
    Li, VC
    CEMENT AND CONCRETE RESEARCH, 2002, 32 (03) : 415 - 423
  • [43] Ballistic limit and damage assessment of hybrid fibre-reinforced cementitious thin composite plates under impact loading
    Signorini, Cesare
    Bracklow, Franz
    Hering, Marcus
    Butler, Marko
    Leicht, Lena
    Schubert, Thomas
    Beigh, Mirza A. B.
    Beckmann, Birgit
    Curbach, Manfred
    Mechtcherine, Viktor
    JOURNAL OF BUILDING ENGINEERING, 2023, 80
  • [44] Structural Performance of Polymer Fiber Reinforced Engineered Cementitious Composites Subjected to Static and Fatigue Flexural Loading
    Sherir, Mohamed A. A.
    Hossain, Khandaker M. A.
    Lachemi, Mohamed
    POLYMERS, 2015, 7 (07) : 1299 - 1330
  • [45] Experimental setup for the bending fatigue of fibre-reinforced composite materials
    Van Paepegem, W
    Degrieck, J
    FATIGUE 2000: FATIGUE & DURABILITY ASSESSMENT OF MATERIALS, COMP ONENTS AND STRUCTURES, 2000, : 115 - 122
  • [46] XFEM Investigation of Engineered Cementitious Composite in Reinforced and Plain Beam Based on Experimental Results
    Asadi, Alanor
    Neya, Bahram Navayi
    Beygi, Morteza Hosseinali
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2024, 22 (11) : 2011 - 2030
  • [47] Experimental Investigation on the Mechanical Properties and Microstructure of Basalt Fiber Reinforced Engineered Cementitious Composite
    Du, Qiang
    Cai, Changlu
    Lv, Jing
    Wu, Jiao
    Pan, Ting
    Zhou, Jie
    MATERIALS, 2020, 13 (17)
  • [48] Study on mechanical properties and constitutive equation of hybrid fiber reinforced cementitious composites under static loading
    Yang H.
    Li J.
    Huang Y.
    Li, Jing (278334902@qq.com), 1600, Bentham Science Publishers B.V., P.O. Box 294, Bussum, 1400 AG, Netherlands (10): : 482 - 491
  • [49] Experimental study of soil stress characteristics of geogrid-reinforced widened embankment under static loadings
    Wang Yi-min
    Yan Cen
    Yu Heng
    Li Qi
    ROCK AND SOIL MECHANICS, 2018, 39 : 311 - 317
  • [50] Static and fatigue behaviour of ECC link slabs in reinforced concrete girder Joint-Free bridges
    Chu, K.
    Hossain, K. M. A.
    Lachemi, M.
    STRUCTURES, 2022, 41 : 1301 - 1310